Power connection cables

Low- and medium-voltage power feeders, welding leads, portable cords, EV charging cables, solar PV leads, submersible pump feeders and armoured mining and marine cables.

How does the cable move?

Pick one or more duties — the list below updates.

116 power connection cables

Voltage
Standard
Sheath
Features

Fixed building and industrial power

LV armoured and unarmoured power distribution cables, building wires, overhead lines and tray feeders.

8 cables
74C068 SH P K1 NA — cable cross-section
74C068 SH P K1 NA74C068 SH P K1 NA Nuclear K1 Class 1E LV Power Cable
300/500 V
Fixed, trailing
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, trailing
ECTFE-HMWPE Cathodic Protection Cable — cable cross-section
ECTFE-HMWPE Cathodic Protection CableECTFE-HMWPE Cathodic Protection Cable
300/500 V
Fixed, trailing
IECPE
300/500 V, IEC, PE sheathFixed, trailing
HMWPE Cathodic Protection Cable — cable cross-section
HMWPE Cathodic Protection CableHMWPE Cathodic Protection Cable
300/500 V
Fixed, trailing
IECPE
300/500 V, IEC, PE sheathFixed, trailing
Nemtek AH-UC1.6 / AH-UC2.5 — cable cross-section
Nemtek AH-UC1.6 / AH-UC2.5Nemtek AH-UC1.6 / AH-UC2.5 Double-Insulated High-Voltage
300/500 V
Fixed, trailing
IECPE
300/500 V, IEC, PE sheathFixed, trailing
NR Type A1 / A2 / A3 — cable cross-section
NR Type A1 / A2 / A3NR Type A1 / A2 / A3 Network Rail Type A1 / A2 / A3 Unarmoured
300/500 V
Fixed, trailing
IECRubber
300/500 V, IEC, Rubber sheathFixed, trailing
PVDF-HMWPE Cathodic Protection Cable — cable cross-section
PVDF-HMWPE Cathodic Protection CablePVDF-HMWPE Cathodic Protection Cable
300/500 V
Fixed, trailing
IECPE
300/500 V, IEC, PE sheathFixed, trailing
UG7OG7KNR / RG7OG7KNR — cable cross-section
UG7OG7KNR / RG7OG7KNRUG7OG7KNR / RG7OG7KNR HEPR-Insulated Screen-Armoured Industrial
300/500 V
Fixed, trailing
IECRubber
300/500 V, IEC, Rubber sheathFixed, trailing
RG7OZR — cable cross-section
RG7OZRRG7OZR Three-Core Armoured HEPR Power Cable
3.6/6 kV – 12/20 kV
Fixed
IECPVC
3.6/6 kV – 12/20 kV, IEC, PVC sheathFixed

Welding & portable power cords

Flexible welding leads, UL portable cords, battery cables and ground-power feeders.

23 cables
H01N2-D — cable cross-section
H01N2-DH01N2-D Welding Cable
100/100 V – 450/750 V
Fixed, trailing
EN / HDRubber
100/100 V – 450/750 V, EN / HD, Rubber sheathFixed, trailing
H01N2-E — cable cross-section
H01N2-EH01N2-E Extra-Flexible Welding Cable
100/100 V – 450/750 V
Fixed, trailing
EN / HDRubber
100/100 V – 450/750 V, EN / HD, Rubber sheathFixed, trailing
Type PPE / PPC-TPE — cable cross-section
Type PPE / PPC-TPEType PPE / PPC-TPE UL/CSA Type PPE / PPC-TPE Portable Power
300/500 V
Fixed, trailing
IECTPE
300/500 V, IEC, TPE sheathFixed, trailing
Type SC / CSA PPC — cable cross-section
Type SC / CSA PPCType SC / CSA PPC UL Type SC / CSA PPC Entertainment Stage
300/500 V
Fixed, trailing
IECRubber
300/500 V, IEC, Rubber sheathFixed, trailing
0361TQ — cable cross-section
0361TQ0361TQ HOFR Welding Cable
100/100 V – 450/750 V
Fixed, trailing
BSPE
100/100 V – 450/750 V, BS, PE sheathFixed, trailing
GP 270 V DC — cable cross-section
GP 270 V DCGP 270 V DC 270 V DC Aircraft Ground-Power Cable
100/100 V – 450/750 V
Fixed, trailing
IECPUR
100/100 V – 450/750 V, IEC, PUR sheathFixed, trailing
GP 28V DC SC — cable cross-section
GP 28V DC SCGP 28V DC SC 28 V DC Single-Core Aircraft Ground-Power Cable with
100/100 V – 450/750 V
Fixed, trailing
IECPUR
100/100 V – 450/750 V, IEC, PUR sheathFixed, trailing
GP 28V DC SF — cable cross-section
GP 28V DC SFGP 28V DC SF 28 V DC Symmetrical Aircraft Ground-Power Cable
100/100 V – 450/750 V
Fixed, trailing
IECPUR
100/100 V – 450/750 V, IEC, PUR sheathFixed, trailing
Super-Trex 600 V Welding Cable — cable cross-section
Super-Trex 600 V Welding CableSuper-Trex 600 V Welding Cable
100/100 V – 450/750 V
Fixed, trailing
IECRubber
100/100 V – 450/750 V, IEC, Rubber sheathFixed, trailing
Water-Cooled Kickless Welding Cable — cable cross-section
Water-Cooled Kickless Welding CableWater-Cooled Kickless Welding Cable
100/100 V – 450/750 V
Fixed, submerged
IECRubber
100/100 V – 450/750 V, IEC, Rubber sheathFixed, submerged
400 Hz Aircraft Ground Power Cable — cable cross-section
400 Hz Aircraft Ground Power Cable400 Hz Aircraft Ground Power Cable
0.6/1 kV
Fixed, trailing
IECPUR
0.6/1 kV, IEC, PUR sheathFixed, trailing
Bus Drop Cable — cable cross-section
Bus Drop CableBus Drop Cable
0.6/1 kV
Fixed
IECPVC
0.6/1 kV, IEC, PVC sheathFixed
SEOOW — cable cross-section
SEOOWSEOOW TPE Portable Cord
0.6/1 kV
Fixed, trailing
UL / CSATPE
0.6/1 kV, UL / CSA, TPE sheathFixed, trailing
SGR — cable cross-section
SGRSGR Rubber Battery Cable
0.6/1 kV
Fixed, motor & traction leads
UL / CSARubber
0.6/1 kV, UL / CSA, Rubber sheathFixed, motor & traction leads
SGT — cable cross-section
SGTSGT PVC Battery Cable
0.6/1 kV
Fixed, motor & traction leads
UL / CSAPVC
0.6/1 kV, UL / CSA, PVC sheathFixed, motor & traction leads
SGX — cable cross-section
SGXSGX Cross-Linked Battery Cable
0.6/1 kV
Fixed, motor & traction leads
UL / CSAPE
0.6/1 kV, UL / CSA, PE sheathFixed, motor & traction leads
SJTOOW — cable cross-section
SJTOOWSJTOOW Portable Cord
0.6/1 kV
Fixed, trailing
UL / CSAPVC
0.6/1 kV, UL / CSA, PVC sheathFixed, trailing
SJTOW — cable cross-section
SJTOWSJTOW Outdoor Portable Cord
0.6/1 kV
Fixed, trailing
UL / CSAPVC
0.6/1 kV, UL / CSA, PVC sheathFixed, trailing
STOOW — cable cross-section
STOOWSTOOW Thermoplastic Portable Cord
0.6/1 kV
Fixed, trailing
UL / CSAPVC
0.6/1 kV, UL / CSA, PVC sheathFixed, trailing
STX — cable cross-section
STXSTX Thin-Wall Battery Cable
0.6/1 kV
Fixed, motor & traction leads
UL / CSAPE
0.6/1 kV, UL / CSA, PE sheathFixed, motor & traction leads
SVT — cable cross-section
SVTSVT Appliance Cord
0.6/1 kV
Fixed, trailing
UL / CSAPVC
0.6/1 kV, UL / CSA, PVC sheathFixed, trailing
FAA L-824 Type B — cable cross-section
FAA L-824 Type BFAA L-824 Type B Airfield Lighting Cable
0.6/1 kV – 1.5 kV
Fixed
UL / CSAPE
0.6/1 kV – 1.5 kV, UL / CSA, PE sheathFixed
FAA L-824 Type C — cable cross-section
FAA L-824 Type CFAA L-824 Type C Airfield Lighting Cable
0.6/1 kV – 1.5 kV
Fixed
UL / CSAPE
0.6/1 kV – 1.5 kV, UL / CSA, PE sheathFixed

EV charging, solar & storage

AC/DC electric vehicle charging cables, solar PV wires and battery storage DC feeders.

19 cables
EV / EVJ — cable cross-section
EV / EVJEV / EVJ UL Type EV / EVJ Thermoplastic Electric Vehicle Charging
300/500 V
Fixed, trailing
IECTPE
300/500 V, IEC, TPE sheathFixed, trailing
EVE / EVJE — cable cross-section
EVE / EVJEEVE / EVJE UL Type EVE / EVJE Elastomer Electric Vehicle Charging
300/500 V
Fixed, trailing
IECTPE
300/500 V, IEC, TPE sheathFixed, trailing
WK 137-Torsion FT4 — WK 137-Torsion FT4 Wind-Turbine Nacelle Drip-Loop Torsion Power Cable
WK 137-Torsion FT4WK 137-Torsion FT4 Wind-Turbine Nacelle Drip-Loop Torsion Power Cable
300/500 V
Fixed, trailing
IECRubber
300/500 V, IEC, Rubber sheathFixed, trailing
(N)TMCHXOEU — cable cross-section
(N)TMCHXOEU(N)TMCHXOEU Single-Core LSZH Wind-Turbine MV Cable
0.6/1 kV
Fixed, motor & traction leads
IECHalogen-free
0.6/1 kV, IEC, Halogen-free sheathFixed, motor & traction leads
(N)TSCGEHXOEU — cable cross-section
(N)TSCGEHXOEU(N)TSCGEHXOEU Three-Core Torsion-Resistant Wind-Turbine MV/HV
0.6/1 kV
Fixed, motor & traction leads
IECHalogen-free
0.6/1 kV, IEC, Halogen-free sheathFixed, motor & traction leads
ConnectEV — cable cross-section
ConnectEVConnectEV
0.6/1 kV
Fixed, trailing
IECHalogen-free
0.6/1 kV, IEC, Halogen-free sheathFixed, trailing
ConnectEV SWA — cable cross-section
ConnectEV SWAConnectEV SWA
0.6/1 kV
Fixed, trailing
IECHalogen-free
0.6/1 kV, IEC, Halogen-free sheathFixed, trailing
EV ProInstall Cat6A — cable cross-section
EV ProInstall Cat6AEV ProInstall Cat6A
0.6/1 kV
Fixed, trailing
IECHalogen-free
0.6/1 kV, IEC, Halogen-free sheathFixed, trailing
EV ProInstall Cat6A SWA — cable cross-section
EV ProInstall Cat6A SWAEV ProInstall Cat6A SWA
0.6/1 kV
Fixed, trailing
IECHalogen-free
0.6/1 kV, IEC, Halogen-free sheathFixed, trailing
H05BZ5-F — cable cross-section
H05BZ5-FH05BZ5-F AC EV Charging Cable
0.6/1 kV
Fixed, trailing
EN / HDPUR
0.6/1 kV, EN / HD, PUR sheathFixed, trailing
H07BZ5-F — cable cross-section
H07BZ5-FH07BZ5-F AC EV Charging Cable
0.6/1 kV
Fixed, trailing
EN / HDPUR
0.6/1 kV, EN / HD, PUR sheathFixed, trailing
Battery Energy Storage DC Cable — cable cross-section
Battery Energy Storage DC CableBattery Energy Storage DC Cable
0.6/1 kV – 1.5 kV
Fixed, motor & traction leads
IECHalogen-free
0.6/1 kV – 1.5 kV, IEC, Halogen-free sheathFixed, motor & traction leads
DC EV Charging Cable — cable cross-section
DC EV Charging CableDC EV Charging Cable
0.6/1 kV – 1.5 kV
Fixed, trailing
IECPUR
0.6/1 kV – 1.5 kV, IEC, PUR sheathFixed, trailing
FG16(O)R16 — cable cross-section
FG16(O)R16FG16(O)R16 EV Charging-Station DC Connection Cable
0.6/1 kV – 1.5 kV
Fixed, trailing
IECPVC
0.6/1 kV – 1.5 kV, IEC, PVC sheathFixed, trailing
FHL2G — cable cross-section
FHL2GFHL2G Automotive High-Voltage Cable
0.6/1 kV – 1.5 kV
Fixed, motor & traction leads
IECSilicone
0.6/1 kV – 1.5 kV, IEC, Silicone sheathFixed, motor & traction leads
FHLR2GCB2G — cable cross-section
FHLR2GCB2GFHLR2GCB2G Shielded Automotive HV Cable
0.6/1 kV – 1.5 kV
Fixed, motor & traction leads
IECSilicone
0.6/1 kV – 1.5 kV, IEC, Silicone sheathFixed, motor & traction leads
H1Z2Z2-K — cable cross-section
H1Z2Z2-KH1Z2Z2-K Solar PV Cable
0.6/1 kV – 1.5 kV
Fixed
EN / HDHalogen-free
0.6/1 kV – 1.5 kV, EN / HD, Halogen-free sheathFixed
Liquid-Cooled High-Power DC Charging Cable — cable cross-section
Liquid-Cooled High-Power DC Charging CableLiquid-Cooled High-Power DC Charging Cable
0.6/1 kV – 1.5 kV
Fixed, submerged
IECPUR
0.6/1 kV – 1.5 kV, IEC, PUR sheathFixed, submerged
PV Wire UL 4703 — cable cross-section
PV Wire UL 4703PV Wire UL 4703 Solar Cable
0.6/1 kV – 1.5 kV
Fixed
UL / CSAPE
0.6/1 kV – 1.5 kV, UL / CSA, PE sheathFixed

Shipboard, offshore & pump power

JIS, LSX and BS 6883 marine power cables, armoured Teck90/MC-HL feeders and ESP pump cables.

23 cables
LSDCOP / LSTCOP — cable cross-section
LSDCOP / LSTCOPLSDCOP / LSTCOP MIL-DTL-24643 LSDCOP / LSTCOP Watertight Portable
300/500 V
Fixed, trailing
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, trailing
LSDPS / LSTPS / LSFPS / LS7PS — cable cross-section
LSDPS / LSTPS / LSFPS / LS7PSLSDPS / LSTPS / LSFPS / LS7PS MIL-DTL-24643 LSDPS / LSTPS / LSFPS
300/500 V
Fixed, trailing
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, trailing
LSDSGU / LSTSGU / LSFSGU / LS7SGU / LSMSCU / LSMSCS — cable cross-section
LSDSGU / LSTSGU / LSFSGU / LS7SGU / LSMSCU / LSMSCSLSDSGU / LSTSGU / LSFSGU / LS7SGU / LSMSCU / LSMSCS MIL-DTL-24643
300/500 V
Fixed, trailing
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, trailing
ACWU90 — cable cross-section
ACWU90ACWU90 Armoured Power Cable
0.6/1 kV
Fixed
UL / CSAPVC
0.6/1 kV, UL / CSA, PVC sheathFixed
BS 6883 A — cable cross-section
BS 6883 ABS 6883 A rmoured Offshore Power Cable
0.6/1 kV
Fixed, offshore & shipboard
BSHalogen-free
0.6/1 kV, BS, Halogen-free sheathFixed, offshore & shipboard
BS 6883 Armoured MV — cable cross-section
BS 6883 Armoured MVBS 6883 Armoured MV Offshore Power Cable
0.6/1 kV
Fixed, offshore & shipboard
BSRubber
0.6/1 kV, BS, Rubber sheathFixed, offshore & shipboard
BS 6883 U — cable cross-section
BS 6883 UBS 6883 U narmoured Offshore Power Cable
0.6/1 kV
Fixed, offshore & shipboard
BSHalogen-free
0.6/1 kV, BS, Halogen-free sheathFixed, offshore & shipboard
DPNP / TPNP / FPNP — cable cross-section
DPNP / TPNP / FPNPDPNP / TPNP / FPNP JIS Flexible Shipboard Rubber Cable
0.6/1 kV
Fixed, offshore & shipboard
IECRubber
0.6/1 kV, IEC, Rubber sheathFixed, offshore & shipboard
DPY / TPY / FPY / 5PY / 6PY — cable cross-section
DPY / TPY / FPY / 5PY / 6PYDPY / TPY / FPY / 5PY / 6PY JIS Unarmoured Shipboard Power Cable
0.6/1 kV
Fixed, offshore & shipboard
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, offshore & shipboard
DPYC / TPYC / FPYC / 5PYC / 6PYC — cable cross-section
DPYC / TPYC / FPYC / 5PYC / 6PYCDPYC / TPYC / FPYC / 5PYC / 6PYC JIS Braid-Armoured Shipboard
0.6/1 kV
Fixed, offshore & shipboard
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, offshore & shipboard
DPYCY / TPYCY / FPYCY / 5PYCY / 6PYCY — cable cross-section
DPYCY / TPYCY / FPYCY / 5PYCY / 6PYCYDPYCY / TPYCY / FPYCY / 5PYCY / 6PYCY JIS Oversheathed Armoured
0.6/1 kV
Fixed, offshore & shipboard
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, offshore & shipboard
EN 50382-2 — cable cross-section
EN 50382-2EN 50382-2 High-Temperature Rolling Stock Power Cable
0.6/1 kV
Fixed, motor & traction leads
EN / HDSilicone
0.6/1 kV, EN / HD, Silicone sheathFixed, motor & traction leads
MC-HL Power — cable cross-section
MC-HL PowerMC-HL Power Metal-Clad Power Cable
0.6/1 kV
Fixed
UL / CSAPVC
0.6/1 kV, UL / CSA, PVC sheathFixed
N2XH — cable cross-section
N2XHN2XH LSZH Power Cable
0.6/1 kV
Fixed
DIN VDEHalogen-free
0.6/1 kV, DIN VDE, Halogen-free sheathFixed
SPYC LV — cable cross-section
SPYC LVSPYC LV JIS Single-Core Shipboard Power Cable
0.6/1 kV
Fixed, offshore & shipboard
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, offshore & shipboard
TECK90 — cable cross-section
TECK90TECK90 Armoured Industrial Cable
0.6/1 kV
Fixed
UL / CSAPVC
0.6/1 kV, UL / CSA, PVC sheathFixed
Flat Electrical Submersible Pump Cable — cable cross-section
Flat Electrical Submersible Pump CableFlat Electrical Submersible Pump Cable
0.6/1 kV – 1.5 kV
Fixed, submerged
IECRubber
0.6/1 kV – 1.5 kV, IEC, Rubber sheathFixed, submerged
LSX Armoured and Sheathed — cable cross-section
LSX Armoured and SheathedLSX Armoured and Sheathed LSZH Shipboard Power Cable
0.6/1 kV – 1.5 kV
Fixed, offshore & shipboard
IECHalogen-free
0.6/1 kV – 1.5 kV, IEC, Halogen-free sheathFixed, offshore & shipboard
LSX Unarmoured — cable cross-section
LSX UnarmouredLSX Unarmoured LSZH Single-Conductor Shipboard Power Cable
0.6/1 kV – 1.5 kV
Fixed, offshore & shipboard
IECHalogen-free
0.6/1 kV – 1.5 kV, IEC, Halogen-free sheathFixed, offshore & shipboard
MLE / Motor Lead Extension — cable cross-section
MLE / Motor Lead ExtensionMLE / Motor Lead Extension ESP Motor Lead Extension Cable
0.6/1 kV – 1.5 kV
Fixed, submerged
IECRubber
0.6/1 kV – 1.5 kV, IEC, Rubber sheathFixed, submerged
Round Electrical Submersible Pump Cable — cable cross-section
Round Electrical Submersible Pump CableRound Electrical Submersible Pump Cable
0.6/1 kV – 1.5 kV
Fixed, submerged
IECRubber
0.6/1 kV – 1.5 kV, IEC, Rubber sheathFixed, submerged
Submersible Pump Cable — cable cross-section
Submersible Pump CableSubmersible Pump Cable
0.6/1 kV – 1.5 kV
Fixed, submerged
IECRubber
0.6/1 kV – 1.5 kV, IEC, Rubber sheathFixed, submerged
SPYC TPYC MV — cable cross-section
SPYC TPYC MVSPYC TPYC MV JIS Medium-Voltage Shipboard Power Cable
3.6/6 kV – 12/20 kV
Fixed, offshore & shipboard
IECHalogen-free
3.6/6 kV – 12/20 kV, IEC, Halogen-free sheathFixed, offshore & shipboard

Medium-voltage and mining feeders

MV distribution cables, armoured shaft and roadway mining feeders, and high-current furnace links.

43 cables
CICC Superconducting Conductor — cable cross-section
CICC Superconducting ConductorCICC Superconducting Conductor
300/500 V
Fixed, trailing
IECRubber
300/500 V, IEC, Rubber sheathFixed, trailing
CORC Cable — cable cross-section
CORC CableCORC Cable Conductor on Round Core (CORC) High-Temperature
300/500 V
Fixed, trailing
IECFluoropolymer
300/500 V, IEC, Fluoropolymer sheathFixed, trailing
EAF Water-Cooled Cable — cable cross-section
EAF Water-Cooled CableEAF Water-Cooled Cable
300/500 V
Fixed, trailing
IECRubber
300/500 V, IEC, Rubber sheathFixed, trailing
HTS Roebel Cable — cable cross-section
HTS Roebel CableHTS Roebel Cable Transposed REBCO High-Temperature
300/500 V
Fixed, trailing
IECFluoropolymer
300/500 V, IEC, Fluoropolymer sheathFixed, trailing
MgB2 Superconducting Link Cable — cable cross-section
MgB2 Superconducting Link CableMgB2 Superconducting Link Cable
300/500 V
Fixed, trailing
IECRubber
300/500 V, IEC, Rubber sheathFixed, trailing
SCGMS 19050 Type 1A / 1B — cable cross-section
SCGMS 19050 Type 1A / 1BSCGMS 19050 Type 1A / 1B Unscreened Mining Feeder & Auxiliary
300/500 V
Fixed, trailing
IECRubber
300/500 V, IEC, Rubber sheathFixed, trailing
Three-Phase HTS Power Cable — cable cross-section
Three-Phase HTS Power CableThree-Phase HTS Power Cable
300/500 V
Fixed, trailing
IECRubber
300/500 V, IEC, Rubber sheathFixed, trailing
Water-Cooled Two-Conductor Coaxial Cable — cable cross-section
Water-Cooled Two-Conductor Coaxial CableWater-Cooled Two-Conductor Coaxial Cable
300/500 V
Fixed, trailing
IECSilicone
300/500 V, IEC, Silicone sheathFixed, trailing
(N)TMCGC11Y — cable cross-section
(N)TMCGC11Y(N)TMCGC11Y Single-Core MV PUR-Sheathed Cable
0.6/1 kV
Fixed
IECPUR
0.6/1 kV, IEC, PUR sheathFixed
MGM 109 Type 1012 / 1013 / 1014 — cable cross-section
MGM 109 Type 1012 / 1013 / 1014MGM 109 Type 1012 / 1013 / 1014 Single-Armoured LV Feeder Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
MGM 109 Type 1023 / 1024 — cable cross-section
MGM 109 Type 1023 / 1024MGM 109 Type 1023 / 1024 Double-Armoured LV Feeder Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
SJEOOW — cable cross-section
SJEOOWSJEOOW TPE Portable Cord
0.6/1 kV
Fixed, trailing
IECTPE
0.6/1 kV, IEC, TPE sheathFixed, trailing
YHKGXSekyn — cable cross-section
YHKGXSekynYHKGXSekyn Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
YHKGXSFoyn — cable cross-section
YHKGXSFoynYHKGXSFoyn Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
YHKGXSFtZnyn — cable cross-section
YHKGXSFtZnynYHKGXSFtZnyn Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
YHKGXSyn — cable cross-section
YHKGXSynYHKGXSyn Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
YHKGYekyn — cable cross-section
YHKGYekynYHKGYekyn Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
YHKGYFoyn — cable cross-section
YHKGYFoynYHKGYFoyn Screened Steel-Wire Armoured PVC Mining Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
YHKGYFtZnyn — cable cross-section
YHKGYFtZnynYHKGYFtZnyn Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
YHKGYyn — cable cross-section
YHKGYynYHKGYyn Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
YKGYFoyn / YKGYFoyn-żo — cable cross-section
YKGYFoyn / YKGYFoyn-żoYKGYFoyn / YKGYFoyn-żo Steel-Wire Armoured PVC Mining Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
YKGYFtZnyn — cable cross-section
YKGYFtZnynYKGYFtZnyn Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
YKGYyn-żo — cable cross-section
YKGYyn-żoYKGYyn-żo Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
YnKGY-żo — cable cross-section
YnKGY-żoYnKGY-żo Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
YnOGY — cable cross-section
YnOGYYnOGY Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
YnOGYek — cable cross-section
YnOGYekYnOGYek Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
YnOGYekm — cable cross-section
YnOGYekmYnOGYekm Cable
0.6/1 kV
Fixed, mine roadway
IECPVC
0.6/1 kV, IEC, PVC sheathFixed, mine roadway
MGM 109 Type 3013 — cable cross-section
MGM 109 Type 3013MGM 109 Type 3013 Cable
3.6/6 kV – 12/20 kV
Fixed, mine roadway
IECPVC
3.6/6 kV – 12/20 kV, IEC, PVC sheathFixed, mine roadway
MGM 109 Type 3023 — cable cross-section
MGM 109 Type 3023MGM 109 Type 3023 Cable
3.6/6 kV – 12/20 kV
Fixed, mine roadway
IECPVC
3.6/6 kV – 12/20 kV, IEC, PVC sheathFixed, mine roadway
MGM 109 Type 3123 — cable cross-section
MGM 109 Type 3123MGM 109 Type 3123 Cable
3.6/6 kV – 12/20 kV
Fixed, mine roadway
IECPVC
3.6/6 kV – 12/20 kV, IEC, PVC sheathFixed, mine roadway
MGM 118 Type 6010 / 6020 — cable cross-section
MGM 118 Type 6010 / 6020MGM 118 Type 6010 / 6020 Unscreened Armoured MV Feeder Cable
3.6/6 kV – 12/20 kV
Fixed, mine roadway
IECPVC
3.6/6 kV – 12/20 kV, IEC, PVC sheathFixed, mine roadway
MGM 118 Type 6110 — cable cross-section
MGM 118 Type 6110MGM 118 Type 6110 Cable
3.6/6 kV – 12/20 kV
Fixed, mine roadway
IECPVC
3.6/6 kV – 12/20 kV, IEC, PVC sheathFixed, mine roadway
NTMCWÖU — cable cross-section
NTMCWÖUNTMCWÖU Extra-Flexible Single-Core MV Connection Cable
3.6/6 kV – 12/20 kV
Fixed
DIN VDERubber
3.6/6 kV – 12/20 kV, DIN VDE, Rubber sheathFixed
RG7H1OR — cable cross-section
RG7H1ORRG7H1OR Three-Core HEPR-Insulated MV Cable
3.6/6 kV – 12/20 kV
Fixed
UL / CSAPVC
3.6/6 kV – 12/20 kV, UL / CSA, PVC sheathFixed
RG7H1OZR — cable cross-section
RG7H1OZRRG7H1OZR Three-Core Screened Armoured MV Cable
3.6/6 kV – 12/20 kV
Fixed
IECPVC
3.6/6 kV – 12/20 kV, IEC, PVC sheathFixed
RG7H1R — cable cross-section
RG7H1RRG7H1R Single-Core HEPR-Insulated MV Cable
3.6/6 kV – 12/20 kV
Fixed
UL / CSAPVC
3.6/6 kV – 12/20 kV, UL / CSA, PVC sheathFixed
Type MV-105 Flexible Single-Conductor — cable cross-section
Type MV-105 Flexible Single-ConductorType MV-105 Flexible Single-Conductor
3.6/6 kV – 12/20 kV
Fixed
UL / CSAHalogen-free
3.6/6 kV – 12/20 kV, UL / CSA, Halogen-free sheathFixed
Type MV-90 / MV-105 Distribution — cable cross-section
Type MV-90 / MV-105 DistributionType MV-90 / MV-105 Distribution MV-90/MV-105 Medium-Voltage
3.6/6 kV – 12/20 kV
Fixed
UL / CSAPVC
3.6/6 kV – 12/20 kV, UL / CSA, PVC sheathFixed
YHKGXSekFtZnyn — cable cross-section
YHKGXSekFtZnynYHKGXSekFtZnyn Cable
3.6/6 kV – 12/20 kV
Fixed, mine roadway
IECPVC
3.6/6 kV – 12/20 kV, IEC, PVC sheathFixed, mine roadway
YHKGYekFtZnyn — cable cross-section
YHKGYekFtZnynYHKGYekFtZnyn Cable
3.6/6 kV – 12/20 kV
Fixed, mine roadway
IECPVC
3.6/6 kV – 12/20 kV, IEC, PVC sheathFixed, mine roadway
10-CHKCU / 22-CHKCU / 35-CHKCU — cable cross-section
10-CHKCU / 22-CHKCU / 35-CHKCU10-CHKCU / 22-CHKCU / 35-CHKCU CHKCU Compact-Substation
6/10 kV – 18/30 kV
Fixed
IECRubber
6/10 kV – 18/30 kV, IEC, Rubber sheathFixed
(N)TMCGCHXOEUK 26-45 kV — cable cross-section
(N)TMCGCHXOEUK 26-45 kV(N)TMCGCHXOEUK 26-45 kV 26/45 kV Screened Flexible Railway
26/45 kV
Fixed, trailing
IECHalogen-free
26/45 kV, IEC, Halogen-free sheathFixed, trailing
(N)TMCWOEU 26-45 kV — cable cross-section
(N)TMCWOEU 26-45 kV(N)TMCWOEU 26-45 kV 26/45 kV Railway Pantograph Connection Cable
26/45 kV
Fixed, trailing
IECRubber
26/45 kV, IEC, Rubber sheathFixed, trailing

Choosing power connection cables

Four things decide most selections. Our engineers check the rest against your application.

Application and movement duty

  • Define whether the cable runs in a fixed tray, energy chain, festoon loop, reel or trailing route.
  • Match travel speed, bend radius and tensile load to the mechanical construction.
  • Select a support element or armour when the cable carries suspended weight or external crush loads.

Voltage class and core layout

  • Match the rated voltage U0/U to the supply system and earthing arrangement.
  • Specify phase cross-sections, protective earth, pilot cores or control pairs required by the machine.
  • Include copper braid, tape or semiconductive screens where EMC or electric-field control is needed.

Operating environment and sheath

  • Choose rubber, PUR, LSZH, PVC, fluoropolymer or silicone sheaths for the thermal and chemical exposure.
  • Verify oil, UV, water immersion, cold-flex or circuit-integrity ratings against site conditions.
  • Check outer diameter and gland compatibility at both terminations.

Standard and documentation

  • Confirm the governing standard family required by the project specification.
  • Verify conductor class, colour code or core numbering for the destination region.
  • Include operating duty and cable length in your enquiry so we can confirm the build.
Filter the range by standard

Questions buyers ask

Not covered here? Send your drawing and an engineer replies within 2 business hours.

Ask on WhatsApp
How do I select the right power connection cable from this range?

Start by filtering the list by movement duty, voltage band and sheath material. Compare how each power connection cable is constructed—conductor flexibility, insulation compound, screening and outer jacket—against your machine's bending radius, travel speed and ambient temperature. Open the product page or datasheet to check core counts, cross-sections and outer diameters before sending your enquiry.

When should power connection cables include metallic screening or armour?

Specify a copper braid or foil screen when power connection cables run near variable-frequency drives, carry analogue or fieldbus signals, or require medium-voltage electric-field control. Choose steel wire braid or armour when the installation faces rock fall, crushing loads or high pulling tension in roadways, decks or subsea routes.

Which outer sheath compound suits harsh industrial environments?

Heavy-duty rubber (PCP or CPE) provides balanced mechanical toughness, weather resistance and thermal stability. Polyurethane (PUR) resists cuts, abrasion and mineral oils on fast-moving chains, reels and trolleys. Halogen-free LSZH compounds reduce smoke and acid gas in tunnels, ships and enclosed buildings, while fluoropolymers and silicone handle extreme heat.

What details should I include in an RFQ for power connection cables?

Include the model designation or governing standard, rated voltage, number of cores and conductor cross-sections, along with the installation method, minimum bend radius, ambient temperature range and required delivery lengths. If you are replacing an existing cable on a machine, share the sheath marking so we can match the specification.

Engineering reference

Background on how power connection cables are built, rated and specified.

Read the full reference

Power connection cables cover industrial constructions engineered for reliable electrical transmission under defined mechanical, thermal and environmental stresses. Selecting the right build requires matching conductor stranding, insulation system, screening and outer sheath compound to the actual installation route rather than relying on nominal cross-section alone.

Across the TEBAOFLEX power connection cables portfolio, models are grouped into functional families so engineers can filter by duty, voltage band, standard family and jacket compound. Each construction addresses a specific balance of flexibility, dielectric strength, electromagnetic compatibility and resistance to oil, water, UV radiation or flame propagation.

Before finalizing a specification, verify the governing national or international standard, operating voltage U0/U, ambient temperature range and minimum bending radius in fixed or moving duty. Where cables interface with connectors, glands or motor terminal boxes, check nominal outer diameter and screen termination geometry early.

When submitting an RFQ for power connection cables, specify the model designation, core count and cross-sections, system voltage, installation method, environmental exposure and required drum or assembly lengths so our engineering team can confirm the exact construction and datasheet.

Compare cables

Voltage
Standard
Sheath
Features
Typical use

Highlighted rows differ between the selected cables.

Filters

Duty

Voltage

Standard

Sheath

Features