Screened power & VFD / motor supply cablesUL TC-ER 2 kV · CSA RWU90 1 kV5-mil Cu Tape (50% Lap)−40 °C Cold Bend · Oil Res II PVC

VFD2KTCP 2 kV RWU90 TC-ER Copper Tape VFD CableDual-listed UL 2 kV TC-ER / CSA RWU90 VFD cable

Dual-certified VFD tray cable rated 2,000 V UL TC-ER / RHW-2 and 1,000 V CSA RWU90 with bare copper conductors, 90 °C XLPE, three bare grounds, 5-mil 50%-lap copper tape, and −40 °C Oil Res II PVC jacket.

Low-EMC design
EMC screen
Oil-resistant
Flame-retardant
Order designation
VFD2KTCP 2kV 3×6 AWG + 3×12 AWG
Outer Ø
22.8 mm
Max. R20
1.320 Ω/km
Weight
1,046 kg/km
Min. bend R
274 mm
All sizes (16)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
2 kV / 1 kV
2 kV UL TC-ER · 1 kV CSA RWU90
EMC screening
5-mil Cu tape
50% helical overlap (double thickness)
Conductor temp.
+90 °C wet/dry
Moisture- & heat-resistant XLPE
Cold / oil rating
−40 °C · Oil II
Cold-bend, Oil Res II & UV black PVC
Min. bend radius
12 × OD
Fixed tray, burial & exposed runs
Size range
14 AWG–750 MCM
Dual UL/CSA · 3C + 3× bare Cu

Typical values for this cable type, based on UL 1277 Type TC-ER · UL 44 RHW-2 · CSA C22.2 No. 38 RWU90 — confirmed in the datasheet and quotation for your order.

Application fit

Is VFD2KTCP 2kV RWU90 TC-ER right for your machine?

Dual-certified VFD tray cable rated 2,000 V UL TC-ER / RHW-2 and 1,000 V CSA RWU90 with bare copper conductors, 90 °C XLPE, three bare grounds, 5-mil 50%-lap copper tape, and −40 °C Oil Res II PVC jacket.

VFD inverter to AC motor screened feeder

Suitable

50%-lap double-thickness 5-mil copper tape plus 3 bare grounds suppress PWM emissions up to 750 kcmil.

Motor stator, traction & converter leads

Suitable

Dual 2 kV UL RHW-2 / 1 kV CSA RWU90 moisture-resistant XLPE handles US and Canadian motor feeders.

Direct-burial & wet conduit run

Suitable

CSA RWU90 direct-burial and −40 °C cold-bend PVC jacket withstand northern oilfield and mining winters.

Fixed installation

Suitable

Oil Res II, sunlight-resistant, UL TC-ER & CSA FT4 rated for trays, conduits, and Class I Div 2.

Energy chain / drag chain

Not suitable

Class B bare copper and 5-mil copper tape are for fixed routing, not continuous drag-chain cycles.

Use (N)12YRDC11Y-J/O PUR

Motorised monospiral reel

Not suitable

Not rated for motorised cable drums; select a rubber reeling cable for spooled equipment.

Use RG / RG-D (N)SHTOEU-J
Typical machinesOil & Gas CableUS & Canadian oil & gas facilitiesCold-climate mines & mineral plantsRefineries & petrochemical traysPulp, paper & heavy industrial millsMunicipal water & pumping stations

Construction

Layer by layer

Shown: VFD2KTCP 2 kV RWU90 TC-ER 3×6 AWG + 3×12 AWG — stranded bare copper RWU90/RHW-2 XLPE phases and three bare copper grounds inside 5-mil 50%-lap copper tape and −40 °C Oil Res II PVC jacket.

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorStranded bare annealed copper (ASTM B8 Class B)ASTM B3 / B8 bare copper
2Phase insulation2 kV moisture- & heat-resistant XLPE (RWU90 / RHW-2, black numbered)UL 44 RHW-2 / CSA C22.2 No. 38 RWU90
3Binder & groundsPolyester separator binder tape + 3 × symmetrical bare Cu groundsSymmetrical 3C+3G core geometry
45-mil copper tape shield5-mil helical bare copper tape shield (50% overlap, double thickness)100% double-lap EMI barrier
5Outer jacketBlack −40 °C cold-bend, Oil Res II & sunlight-resistant PVCUL 1277 TC-ER · CSA C22.2 No. 230

VFD2KTCP 2 kV (UL TC-ER / CSA RWU90)

Three black numbered RWU90/RHW-2 XLPE phases + three bare Cu grounds under 5-mil 50%-lap Cu tape (14 AWG–750 kcmil).

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL 1277 Type TC-ER · UL 44 RHW-2 · CSA C22.2 No. 38 RWU90. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
2,000 V UL TC-ER · 1,000 V CSA RWU90
Conductor class
ASTM B8 Class B bare copper
EMC shield
5-mil bare Cu tape (50% double lap)
Grounding system
3 × symmetrical bare Cu in interstices

Thermal

Max. conductor temp.
+90 °C wet or dry (RWU90 / RHW-2)
Cold bend rating
−40 °C cold bend & impact
Min. bending radius
12 × OD (Cu-tape shielded)

Resistance

Flame test
IEEE 1202 / CSA FT4 / UL 1685
Oil & UV ratings
Oil Res II · Sunlight · Direct Burial
Hazardous locations
NEC / CEC Class I Div 2

Sizes

3C+3G Symmetrical (UL TC-ER / CSA RWU90)
Phase + 3×
Ground (AWG)
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
12×D mm
3×14 AWG + 3×18 AWG15.68.450130341187
3×12 AWG + 3×16 AWG16.65.310180428199
3×10 AWG + 3×14 AWG17.93.340259560215
3×8 AWG + 3×14 AWG20.72.100354759248
3×6 AWG + 3×12 AWG22.81.3205291,046274
3×4 AWG + 3×12 AWG26.50.8327581,468318
3×2 AWG + 3×10 AWG30.90.5231,1662,166371
3×1 AWG + 3×8 AWG32.90.4151,5002,681395
3×1/0 AWG + 3×6 AWG35.10.3291,9473,354421
3×2/0 AWG + 3×6 AWG37.60.2612,3363,977451
3×3/0 AWG + 3×4 AWG41.10.2073,0485,076493
3×4/0 AWG + 3×4 AWG44.30.1643,6676,057532
3×250 kcmil + 3×4 AWG48.40.1394,2167,026581
3×350 kcmil + 3×2 AWG54.10.0995,9639,657649
3×500 kcmil + 3×2 AWG61.30.0708,07612,929736
3×750 kcmil + 3×1/0 AWG73.60.04612,13719,262883
  • Conductor max. DC resistance R20 follows ASTM B8 Class B bare annealed copper at 20 °C.
  • Dual UL 1277 TC-ER (2,000 V) and CSA C22.2 No. 38 RWU90 (1,000 V) certification covers both US NEC and Canadian CEC tray and direct-burial installations.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC high-voltage dielectric testPer UL 44 RHW-2 2 kV & CSA RWU90Every manufactured reel
Conductor DC resistance checkPer ASTM B8 Class B at 20 °CEvery reel length
Sample tests
−40 °C cold bend & Oil Res IICSA −40 °C cold bend & UL Oil Res IIPer production lot
Vertical tray flame testIEEE 1202 / CSA FT4 / UL 1685Type approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL 1277 Type TC-ER (2,000 V) · UL 44 RHW-2CSA C22.2 No. 38 RWU90 (1,000 V) · C22.2 No. 230IEEE 1202 / FT4 · −40 °C Cold Bend · Oil Res II

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

VFD2KTCP 2kV RWU90 TC-ER TEBAOFLEX.COM UL 2000V CSA 1000V OIL RES II -40C [Size]
Delivery form
Cut-to-length or wooden export reels
Standard drum lengths
305 m (1,000 ft) · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-20
Updated
2026-11-20

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

Why does VFD2KTCP list 2,000 V under UL and 1,000 V under CSA?
UL 1277 Type TC-ER / UL 44 RHW-2 certifies the heavy-wall XLPE insulation at 2,000 V for US industrial drive runs, while Canadian CSA C22.2 No. 38 RWU90 certifies the same construction at 1,000 V for direct-burial and tray installations across Canada.
What does Oil Res II and −40 °C cold bend mean for field installation?
Oil Res II confirms prolonged resistance to petroleum and synthetic lubricants at elevated temperatures, while −40 °C cold bend ensures the PVC jacket resists cracking during winter installation in northern oilfields and mines.
How large are the available conductor gauges on VFD2KTCP?
VFD2KTCP spans 14 AWG through 750 kcmil with three symmetrical bare copper grounds and 50%-overlapped 5-mil copper tape shielding, covering small auxiliary pumps up to multi-hundred-horsepower VFD feeders.
How should the EMC shield and symmetrical grounds of VFD2KTCP 2kV RWU90 TC-ER be terminated?
Bond the metallic EMC shield circumferentially (360°) at both the inverter cabinet and motor terminal box using EMC cable glands or constant-force springs, and connect all protective ground conductors cleanly to the earth busbar.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for VFD2KTCP 2kV RWU90 TC-ER

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

VFD2KTCP 2 kV RWU90 TC-ER Copper Tape VFD Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote