Immersion & wet locations
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Product
UL 83 Type THW / THHN-THWN 600V Heavy-Duty Flat Jacketed & Twisted Unjacketed Deep Well Submersible Pump Cable (Flat Parallel Jacketed & Twisted Heavy-Duty Series) (UL 83 / NEC Art. 310, 600 V, -40 °C to +75 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on UL 83 Listed Type THW / THHN-THWN & NEC 250-122 Pump Standard — confirmed in the datasheet and quotation for your order.
Application fit
UL 83 Type THW / THHN-THWN 600V Heavy-Duty Flat Jacketed & Twisted Unjacketed Deep Well Submersible Pump Cable (Flat Parallel Jacketed & Twisted Heavy-Duty Series) (UL 83 / NEC Art. 310, 600 V, -40 °C to +75 °C, min. bend radius 6 × OD).
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.
Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.
Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.
Outboard marine and feeder construction is not designed for high-speed crane festoon trolleys.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: UL 83 TYPE THW PUMP (UL 83 Listed Type THW / THHN-THWN & NEC 250-122 Pump Standard) featuring stranded bare copper (3×phase + 1×gnd), ul 83 type thw pvc + nylon insulation and heavy-duty black pvc outer jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Bare Copper (3×Phase + 1×GND) | ASTM B3/B8 19- or 37-strand concentric bare copper + NEC 250-122 ground core |
| 2 | UL 83 Type THW PVC + Nylon Insulation | 600 V 75 °C wet heat/moisture-resistant PVC (Black, Red, Yellow, Green) + clear Nylon |
| 3 | Parallel Flat / Twisted Core Assembly | Flat parallel construction (Flat Parallel Jacketed) or twisted (Twisted Heavy-Duty) |
| 4 | Heavy-Duty Black PVC Outer Jacket | 1.14–1.65 mm abrasion-, acid-, oil- and sunlight-resistant black PVC flat jacket |
Built to UL 83 Listed Type THW / THHN-THWN & NEC 250-122 Pump Standard with stranded bare copper (3×phase + 1×gnd) and heavy-duty black pvc outer jacket
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to UL 83 Listed Type THW / THHN-THWN & NEC 250-122 Pump Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| UL 83 TYPE THW PUMP Construction Schedule (−40…+75 °C) | |||||||
| UL 83 TYPE THW PUMP 4G16 mm² | 4G16 mm² (3×16 + 1G16) | IEC 60228 Class 5 flexible Cu/SnCu | 21.8 | 840 | 2.4 | 130 | |
| UL 83 TYPE THW PUMP 4G35 mm² | 4G35 mm² (3×35 + 1G16) | IEC 60228 Class 5 flexible Cu/SnCu | 28.6 | 1,620 | 5.2 | 172 | |
| UL 83 TYPE THW PUMP 3×70 + 3G16 mm² | 3 × 70 mm² + 3G16 mm² | IEC 60228 Class 5 flexible Cu/SnCu | 38.4 | 3,180 | 10.5 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4G16 mm² (3×16 + 1G16) | 1.21 | 600 V (94 A submerged) | −40…+75 °C |
| 4G35 mm² (3×35 + 1G16) | 0.55 | 600 V (152 A submerged) | −40…+75 °C |
| 3 × 70 mm² + 3G16 mm² | 0.27 | 600 V (235 A submerged) | −40…+75 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (UL 83 Listed Type THW / THHN-THWN & NEC 250-122 Pump Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within UL 83 Listed Type THW / THHN-THWN & NEC 250-122 Pump Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (UL 83 Listed Type THW / THHN-THWN & NEC 250-122 Pump Standard) | Zero dielectric breakdown and verified insulation resistance for 600 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (UL 83 Listed Type THW / THHN-THWN & NEC 250-122 Pump Standard) | Verified submersion integrity, tensile load and thermal stability across −40…+75 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.