37-102 CIRVFDA 2 kV MSHA Heavy-Duty VFD Cable2000 V MSHA flame-tested crush-resistant mining & rig VFD cable

37-102 CIRVFDA 2 kV MSHA pairs extra-flexible tinned copper conductors and 2000 V thermoset insulation with dual EMC screening and an MSHA-approved crush-resistant CPE jacket for mining and oilfield drives.

Low-EMC design
EMC screen
Flame-retardant
Outdoor & humid
Order designation
37-102 CIRVFDA 2kV MSHA 3×2 AWG + 3×10 AWG
Outer Ø
33.2 mm
Max. R20
0.561 Ω/km
Weight
2,201 kg/km
Min. bend R
332 mm
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
2000 V
AC test voltage 6 kV AC
EMC screening
Foil + TCWB
Low transfer impedance EMC shield
Temp. (fixed)
-40°C…+90°C
Flexing: -30 °C to +90 °C
Min. bend radius
10 × OD
Fixed routing in trays & ducts
Conductor
Tinned Cu · Cl.K
ASTM B172 / B8 copper
Size range
14 AWG–500 kcmil
12 standard configurations

Typical values for this cable type, based on MSHA 30 CFR 18.64 · ICEA S-75-381 · UL 1277 Type TC-ER — confirmed in the datasheet and quotation for your order.

Application fit

Is 37-102 CIRVFDA 2kV MSHA right for your machine?

37-102 CIRVFDA 2 kV MSHA pairs extra-flexible tinned copper conductors and 2000 V thermoset insulation with dual EMC screening and an MSHA-approved crush-resistant CPE jacket for mining and oilfield drives.

VFD inverter to AC motor screened feeder

Suitable

Low-capacitance 2000 V XLPE/EPR construction and EMC screen suppress PWM switching noise between inverter and AC motor.

Motor stator, traction & converter leads

Suitable

Balanced 2000 V XLPE/EPR geometry cuts common-mode bearing currents and terminates cleanly inside motor junction boxes.

Quarry mobile substation & pit feeder

Suitable

Cut- and impact-resistant 2000 V XLPE/EPR construction powers portable quarry substations, crushers, and mobile pit distribution skids.

Offshore mud pump & top drive

Suitable

Heavy-duty 2000 V XLPE/EPR construction resists drilling muds, oil, and vibration on offshore top drives and mud-pump skids.

Energy chain / drag chain

Not suitable

2000 V XLPE/EPR construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Motorised monospiral reel

Not suitable

2000 V XLPE/EPR build lacks anti-torsion tensile reinforcement for motorised drum reeling; select a dedicated reeling cable.

Use RG / RG-D (N)SHTOEU-J
Typical machinesMining & TunnellingVariable frequency drive (VFD) motor baysIndustrial pumps, fans & compressor skidsProcess plants, oil & gas & HVAC systemsHeavy manufacturing & plant MCC feeders

Construction

Layer by layer

Representative construction of 37-102 CIRVFDA 2kV MSHA: tinned copper conductors, 2000 V thermoset EPR/XLPE (90 °C wet/dry), 100% foil + ≥ 85% tinned copper braid + 3 symmetrical grounds, and Black MSHA flame- & abrasion-resistant heavy-duty CPE jacket.

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorASTM B172 Class K flexible tinned annealed copperASTM B172 Class K / UL 1277
2Core insulation2000 V thermoset EPR/XLPE (90 °C wet/dry)MSHA 30 CFR 18.64
3Core assembly & separatorConcentric cabled assembly with low-friction fleece or polyester binder tapeMSHA 30 CFR 18.64
4EMC metallic screen100% foil + ≥ 85% tinned copper braid + 3 symmetrical groundsEMC ≥ 85% / 100% foil
5Outer sheathBlack MSHA flame- & abrasion-resistant heavy-duty CPE jacketMSHA Flame Test

37-102 CIRVFDA 2kV MSHA 3C + 3G Symmetrical

Three numbered black XLPE phase conductors with three symmetrically laid interstitial grounds under EMC shield.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on MSHA 30 CFR 18.64 · ICEA S-75-381 · UL 1277 Type TC-ER. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage U0/U
2000 V
AC test voltage
6 kV AC / 5 min
Conductor class
ASTM B172 Class K tinned Cu
EMC screen
100% foil + ≥ 85% tinned copper braid + 3
Insulation resistance
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-40 °C to +90 °C
Temp. range (flexing)
-30 °C to +90 °C
Short-circuit temp.
+250 °C (5 s)
Min. bending radius
10 × OD (fixed)

Resistance

Flame retardance
MSHA Flame Test
Oil & chemical perf.
IEEE 1202 / FT4
Environmental / EMC
Oil, Mud & Crush Resistant
Outer sheath
Black MSHA flame- & abrasion-resistant

Sizes

3C + 3G Symmetrical (AWG/kcmil)
Cores ×
AWG/kcmil
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
10×D mm
3×14 AWG + 3×18 AWG17.59.070129364175
3×12 AWG + 3×16 AWG18.65.710179454186
3×10 AWG + 3×14 AWG20.03.590257589200
3×8 AWG + 3×14 AWG22.82.260351787228
3×6 AWG + 3×12 AWG25.01.4205261,080250
3×4 AWG + 3×12 AWG28.70.8927531,499287
3×2 AWG + 3×10 AWG33.20.5611,1602,201332
3×1/0 AWG + 3×6 AWG37.60.3531,9393,401376
3×2/0 AWG + 3×6 AWG40.20.2802,3284,030402
3×4/0 AWG + 3×4 AWG47.10.1763,6566,122471
3×350 kcmil + 3×2 AWG57.20.1075,9499,741572
3×500 kcmil + 3×2 AWG64.70.0758,05913,036647
  • Max. conductor DC resistance R20 at 20 °C per ASTM B172 / B8 (tinned copper).
  • Minimum bending radius calculated at 10 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC high-voltage dielectric test6 kV AC for 5 min without breakdownEvery manufactured drum
Conductor DC resistance testPer ASTM B172 / B8 at 20 °CEvery drum length
Sample tests
EMC screen coverage & insulation checkFoil + TCWB continuity & wall thicknessPer production lot
Flame & environmental qualificationMSHA Flame Test · IEEE 1202 / FT4Type approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

MSHA 30 CFR 18.64ICEA S-75-381UL 1277 Type TC-EREN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

37-102 CIRVFDA 2kV MSHA 2000 V TEBAOFLEX.COM [MSHA 30 CFR 18.64] [Size] [Metre mark]
Delivery form
Cut-to-length or wooden export reels
Standard drum lengths
305 m (1,000 ft) · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-21
Updated
2026-11-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes 37-102 CIRVFDA 2kV MSHA suitable for 2000 V industrial installations?
37-102 CIRVFDA 2kV MSHA combines tinned copper conductors, 2000 V thermoset EPR/XLPE (90 °C wet/dry), and 100% foil + ≥ 85% tinned copper braid + 3 symmetrical grounds inside a Black MSHA flame- & abrasion-resistant heavy-duty CPE jacket. MSHA-listed 2 kV jacket resists rock impact, drilling muds, and severe mine haulage environments.
Can 37-102 CIRVFDA 2kV MSHA operate inside continuous drag chains or moving axes?
No. 37-102 CIRVFDA 2kV MSHA is engineered for stationary tray, conduit, or machine-frame routing at 10 × OD minimum bending radius; choose a PUR drag-chain cable for continuous flexing.
How should the EMC shield of 37-102 CIRVFDA 2kV MSHA be grounded at termination?
Bond the metallic screen circumferentially (360°) at both drive and motor ends using EMC cable glands or low-impedance shielding clamps to minimize high-frequency transfer impedance.
What standards, drum lengths, and test certificates accompany 37-102 CIRVFDA 2kV MSHA?
37-102 CIRVFDA 2kV MSHA conforms to MSHA 30 CFR 18.64, ICEA S-75-381, UL 1277 Type TC-ER (MSHA Flame Test) and ships cut-to-length or on export drums with an EN 10204 3.1 routine test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for 37-102 CIRVFDA 2kV MSHA

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

37-102 CIRVFDA 2 kV MSHA Heavy-Duty VFD Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 