VFD inverter to AC motor screened feeder
Low-capacitance 2000 V XLPE/EPR construction and EMC screen suppress PWM switching noise between inverter and AC motor.
Product
37-102 CIRVFDA 2 kV MSHA pairs extra-flexible tinned copper conductors and 2000 V thermoset insulation with dual EMC screening and an MSHA-approved crush-resistant CPE jacket for mining and oilfield drives.
Typical values for this cable type, based on MSHA 30 CFR 18.64 · ICEA S-75-381 · UL 1277 Type TC-ER — confirmed in the datasheet and quotation for your order.
Application fit
37-102 CIRVFDA 2 kV MSHA pairs extra-flexible tinned copper conductors and 2000 V thermoset insulation with dual EMC screening and an MSHA-approved crush-resistant CPE jacket for mining and oilfield drives.
Low-capacitance 2000 V XLPE/EPR construction and EMC screen suppress PWM switching noise between inverter and AC motor.
Balanced 2000 V XLPE/EPR geometry cuts common-mode bearing currents and terminates cleanly inside motor junction boxes.
Cut- and impact-resistant 2000 V XLPE/EPR construction powers portable quarry substations, crushers, and mobile pit distribution skids.
Heavy-duty 2000 V XLPE/EPR construction resists drilling muds, oil, and vibration on offshore top drives and mud-pump skids.
2000 V XLPE/EPR construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR2000 V XLPE/EPR build lacks anti-torsion tensile reinforcement for motorised drum reeling; select a dedicated reeling cable.
Use RG / RG-D (N)SHTOEU-JConstruction
Representative construction of 37-102 CIRVFDA 2kV MSHA: tinned copper conductors, 2000 V thermoset EPR/XLPE (90 °C wet/dry), 100% foil + ≥ 85% tinned copper braid + 3 symmetrical grounds, and Black MSHA flame- & abrasion-resistant heavy-duty CPE jacket.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | ASTM B172 Class K flexible tinned annealed copperASTM B172 Class K / UL 1277 |
| 2 | Core insulation | 2000 V thermoset EPR/XLPE (90 °C wet/dry)MSHA 30 CFR 18.64 |
| 3 | Core assembly & separator | Concentric cabled assembly with low-friction fleece or polyester binder tapeMSHA 30 CFR 18.64 |
| 4 | EMC metallic screen | 100% foil + ≥ 85% tinned copper braid + 3 symmetrical groundsEMC ≥ 85% / 100% foil |
| 5 | Outer sheath | Black MSHA flame- & abrasion-resistant heavy-duty CPE jacketMSHA Flame Test |
Three numbered black XLPE phase conductors with three symmetrically laid interstitial grounds under EMC shield.
Technical data
Sizes
| Cores × AWG/kcmil | Outer Ø ≈ mm | Max. R20 Ω/km | Copper index kg/km | Weight ≈ kg/km | Min. bend R 10×D mm |
|---|---|---|---|---|---|
| 3×14 AWG + 3×18 AWG | 17.5 | 9.070 | 129 | 364 | 175 |
| 3×12 AWG + 3×16 AWG | 18.6 | 5.710 | 179 | 454 | 186 |
| 3×10 AWG + 3×14 AWG | 20.0 | 3.590 | 257 | 589 | 200 |
| 3×8 AWG + 3×14 AWG | 22.8 | 2.260 | 351 | 787 | 228 |
| 3×6 AWG + 3×12 AWG | 25.0 | 1.420 | 526 | 1,080 | 250 |
| 3×4 AWG + 3×12 AWG | 28.7 | 0.892 | 753 | 1,499 | 287 |
| 3×2 AWG + 3×10 AWG | 33.2 | 0.561 | 1,160 | 2,201 | 332 |
| 3×1/0 AWG + 3×6 AWG | 37.6 | 0.353 | 1,939 | 3,401 | 376 |
| 3×2/0 AWG + 3×6 AWG | 40.2 | 0.280 | 2,328 | 4,030 | 402 |
| 3×4/0 AWG + 3×4 AWG | 47.1 | 0.176 | 3,656 | 6,122 | 471 |
| 3×350 kcmil + 3×2 AWG | 57.2 | 0.107 | 5,949 | 9,741 | 572 |
| 3×500 kcmil + 3×2 AWG | 64.7 | 0.075 | 8,059 | 13,036 | 647 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC high-voltage dielectric test | 6 kV AC for 5 min without breakdown | Every manufactured drum |
| Conductor DC resistance test | Per ASTM B172 / B8 at 20 °C | Every drum length |
| Sample tests | ||
| EMC screen coverage & insulation check | Foil + TCWB continuity & wall thickness | Per production lot |
| Flame & environmental qualification | MSHA Flame Test · IEEE 1202 / FT4 | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.