Offshore platform & shipboard deck trays
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Product
LKSM-HF & LKSM-SHF2 0.6/1 kV XLPE-Insulated Copper-Wire-Braid Armoured SHF1 / Oil-Resistant SHF2 Marine & Offshore Power and Control Cable (IEC 60092-353, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A — confirmed in the datasheet and quotation for your order.
Application fit
LKSM-HF & LKSM-SHF2 0.6/1 kV XLPE-Insulated Copper-Wire-Braid Armoured SHF1 / Oil-Resistant SHF2 Marine & Offshore Power and Control Cable (IEC 60092-353, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.
Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.
Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.
Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: LKSM-HF & LKSM-SHF2 0.6/1 KV (IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) featuring stranded copper conductors (7g2.5 mm²), number-coded xlpe insulation and shf1 / cross-linked shf2 outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Copper Conductors (7G2.5 mm²) | IEC 60228 Class 2 / Class 5 annealed copper conductors |
| 2 | Number-Coded XLPE Insulation | White XLPE cores printed 1–6 plus Green/Yellow earth conductor |
| 3 | Halogen-Free Bedding Layer | Extruded flame-retardant halogen-free filler and tape bedding |
| 4 | Tinned Copper Braid Armour (LKSM) | High-density tinned copper wire braid for mechanical & EMC protection |
| 5 | SHF1 / Cross-Linked SHF2 Outer Sheath | Black halogen-free polyolefin (SHF1) or oil-resistant elastomer (SHF2) |
Built to IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A with stranded copper conductors (7g2.5 mm²) and shf1 / cross-linked shf2 outer sheath
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| LKSM-HF & LKSM-SHF2 0.6/1 KV Construction Schedule (−40…+90 °C) | |||||||
| LKSM-HF 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (4G16) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 3.8 | 135 | |
| LKSM-HF 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (4G35) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 7.4 | 175 | |
| LKSM-HF 3×70+1G35 mm² | 3 × 70 + 1G35 mm² (4G70) | IEC 60228 Class 2/5 Cu/SnCu | 38.2 | 3,260 | 14.8 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (4G16) | 1.15 | 0.6/1 kV (98 A) | −40…+90 °C |
| 3 × 35 + 1G16 mm² (4G35) | 0.52 | 0.6/1 kV (158 A) | −40…+90 °C |
| 3 × 70 + 1G35 mm² (4G70) | 0.27 | 0.6/1 kV (245 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.