N2XSY 6/10 kV – 18/30 kV Cu/XLPE/CWS/PVC Single-Core MV Power CableDIN VDE 0276-620 / HD 620 S2 / IEC 60502-2 · 6/10 kV – 18/30 kV · -20 °C to +90 °C industrial

N2XSY 6/10 kV – 18/30 kV Cu/XLPE/CWS/PVC Medium-Voltage Single-Core Power Cable (N2XSY) engineered to DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2 for 6/10 kV – 18/30 kV service across -20 °C to +90 °C, featuring stranded copper conductor and pvc outer sheath

Approved
Low-EMC design
EMC screen
Outdoor & humid
Order designation
N2XSY 4G2.5
Outer Ø ≈
10.8 mm
Total weight ≈
186 kg/km
Min. bend R (fixed)
86 mm
Configuration
4 × 2.5 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
6/10 kV – 18/30
Per DIN VDE 0276-620 / HD 620 S2
Operating temp.
−20…+90 °C
Continuous thermal rating
Min. bend radius
15 × OD
Installed / fixed routing
Conductor
copper conductor
High-conductivity copper conductor
Outer layer
PVC outer sheath
Extruded PVC outer sheath protective
Standard
DIN VDE 0276-620
DIN VDE 0276-620 / HD 620 S2 / IEC

Typical values for this cable type, based on DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2 — confirmed in the datasheet and quotation for your order.

Application fit

Is N2XSY right for your machine?

N2XSY 6/10 kV – 18/30 kV Cu/XLPE/CWS/PVC Medium-Voltage Single-Core Power Cable (N2XSY) engineered to DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2 for 6/10 kV – 18/30 kV service across -20 °C to +90 °C, featuring stranded copper conductor and pvc outer sheath

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 15 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesRenewable Energy & EV ChargingHigh-Voltage Grid & Substation InterconnectsWind, Solar & Hydro Power EvacuationUtility Overhead & Underground DistributionIndustrial Power InfrastructureAutomated Assembly & Packaging Lines

Construction

Layer by layer

Shown: N2XSY (DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2) with stranded copper conductor, inner semiconducting layer and pvc outer sheath (9-layer construction).

123456789
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper conductorHigh-conductivity copper conductor per DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2
2Inner semiconducting layerExtruded Inner semiconducting layer stress-control layerDIN VDE 0276-620 / HD 620 S2 / IEC 60502-2
3XLPE insulationExtruded XLPE insulation dielectric (continuous layer)DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2
4Outer semiconducting layerExtruded Outer semiconducting layer stress-control layerDIN VDE 0276-620 / HD 620 S2 / IEC 60502-2
5Conductive tapeHelically applied conductive tapeDIN VDE 0276-620 / HD 620 S2 / IEC 60502-2
6Copper wire screenCopper wire screen metallic electromagnetic screen (helically applied wires)DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2
7Copper counter-helix tapeHelically applied copper counter-helix tapeDIN VDE 0276-620 / HD 620 S2 / IEC 60502-2
8Nonconducting separator tapeHelically applied nonconducting separator tapeDIN VDE 0276-620 / HD 620 S2 / IEC 60502-2
9PVC outer sheathExtruded PVC outer sheath protective layer (continuous layer)DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2

N2XSY — Standard Execution

Built to DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2 with stranded copper conductor and pvc outer sheath

N2XSY — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2

N2XSY — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
6/10 kV – 18/30 kV (DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2)
Conductor construction
Stranded copper conductor — High-conductivity copper conductor per DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2
Primary insulation / dielectric
Inner semiconducting layer — Extruded Inner semiconducting layer stress-control layer

Thermal

Continuous operating temperature
−20…+90 °C per DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
PVC outer sheath — Extruded PVC outer sheath protective layer (continuous layer)
Minimum bending radius
15 × OD (installed / static routing)
Layer count & geometry
9 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
N2XSY
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard N2XSY cable sizes

Manufactured to DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2 across standard single-core and multi-core cross-sections.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
N2XSY Standard Production Schedule (6/10 kV – 18/30 kV · −20…+90 °C)
N2XSY 3G1.53 × 1.5 mm²8.410568
N2XSY 4G1.54 × 1.5 mm²9.212874
N2XSY 5G1.55 × 1.5 mm²10.115681
N2XSY 3G2.53 × 2.5 mm²9.814878
N2XSY 4G2.54 × 2.5 mm²10.818686
N2XSY 5G2.55 × 2.5 mm²11.922895
N2XSY 4G44 × 4.0 mm²12.6268101
N2XSY 4G64 × 6.0 mm²14.2365114
N2XSY 4G104 × 10 mm²17.5580140
N2XSY 4G164 × 16 mm²20.4845163
N2XSY 4G254 × 25 mm²24.81,290198
N2XSY 4G354 × 35 mm²27.91,710223
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Single-core and multi-core sizes from 0.5 mm² up to 630 mm² (or AWG/kcmil) available per DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2)DC resistance at 20 °C and geometry within DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2)Full compliance with DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2 across −20…+90 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0276-620 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX N2XSY <size> DIN VDE 0276-620 6/10 kV – 18/30 kV CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define N2XSY (N2XSY 6/10 kV – 18/30 kV Cu/XLPE/CWS/PVC Medium-Voltage Single-Core Power Cable)?
N2XSY (N2XSY 6/10 kV – 18/30 kV Cu/XLPE/CWS/PVC Medium-Voltage Single-Core Power Cable) is manufactured in accordance with DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2 for 6/10 kV – 18/30 kV service over -20 °C to +90 °C. Its 9-layer construction comprises stranded copper conductor, inner semiconducting layer, xlpe insulation, outer semiconducting layer, conductive tape, copper wire screen, copper counter-helix tape, nonconducting separator tape, pvc outer sheath.
What is the minimum bending radius and installation temperature for N2XSY?
The minimum installed bending radius for N2XSY is 15 × OD across its continuous operating temperature range of -20 °C to +90 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of N2XSY arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper conductor (High-conductivity copper conductor per DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2); (02) Inner semiconducting layer (Extruded Inner semiconducting layer stress-control layer); (03) XLPE insulation (Extruded XLPE insulation dielectric (continuous layer)); (04) Outer semiconducting layer (Extruded Outer semiconducting layer stress-control layer); (05) Conductive tape (Helically applied conductive tape); (06) Copper wire screen (Copper wire screen metallic electromagnetic screen (helically applied wires)); (07) Copper counter-helix tape (Helically applied copper counter-helix tape); (08) Nonconducting separator tape (Helically applied nonconducting separator tape); (09) PVC outer sheath (Extruded PVC outer sheath protective layer (continuous layer)).
What factory test certificates are supplied with N2XSY?
Every production drum or spool of N2XSY undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per DIN VDE 0276-620 / HD 620 S2 / IEC 60502-2, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for N2XSY

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

N2XSY 6/10 kV – 18/30 kV Cu/XLPE/CWS/PVC Single-Core MV Power Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 