NYCY 0.6/1 kV PVC Power & Control Cable with Concentric Copper WireDIN VDE 0276-603 · 0.6/1 kV · -30 °C to +70 °C industrial NYCY construction

NYCY 0.6/1 kV PVC Power & Control Cable with Concentric Copper Wire & Counter-Helix Screen engineered to DIN VDE 0276-603 for 0.6/1 kV service across -30 °C to +70 °C, featuring stranded copper conductor and pvc outer sheath with minimum bending radius 12 × OD.

Approved
Low-EMC design
EMC screen
Outdoor & humid
Order designation
NYCY 4G2.5
Outer Ø ≈
10.8 mm
Total weight ≈
186 kg/km
Min. bend R (fixed)
86 mm
Configuration
4 × 2.5 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Per DIN VDE 0276-603
Operating temp.
−30…+70 °C
Continuous thermal rating
Min. bend radius
12 × OD
Installed / fixed routing
Conductor
copper conductor
High-conductivity copper conductor
Outer layer
PVC outer sheath
Extruded PVC outer sheath protective
Standard
DIN VDE 0276-603
DIN VDE 0276-603

Typical values for this cable type, based on DIN VDE 0276-603 — confirmed in the datasheet and quotation for your order.

Application fit

Is NYCY right for your machine?

NYCY 0.6/1 kV PVC Power & Control Cable with Concentric Copper Wire & Counter-Helix Screen engineered to DIN VDE 0276-603 for 0.6/1 kV service across -30 °C to +70 °C, featuring stranded copper conductor and pvc outer sheath with minimum bending radius 12 × OD.

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with DIN VDE 0276-603.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 12 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesBuilding & Fire SafetyCommercial & Residential Building DistributionData Centers & Public InfrastructureFire-Safe Evacuation & Riser ShaftsIndustrial Plant Balance-of-Plant WiringAutomated Assembly & Packaging Lines

Construction

Layer by layer

Shown: NYCY (DIN VDE 0276-603) with stranded copper conductor, pvc core insulation and pvc outer sheath (6-layer construction).

123456
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper conductorHigh-conductivity copper conductor per DIN VDE 0276-603DIN VDE 0276-603
2PVC core insulationExtruded PVC dielectric (individual core / group layer)DIN VDE 0276-603
3Butyl/PVC filler beddingExtruded Butyl/PVC filler bedding protective layer (continuous layer)DIN VDE 0276-603
4Concentric copper wire screenConcentric copper wire screen metallic electromagnetic screen (helically applied wires)DIN VDE 0276-603
5Copper tapeCopper tape metallic electromagnetic screen (lapped tape)DIN VDE 0276-603
6PVC outer sheathExtruded PVC outer sheath protective layer (continuous layer)DIN VDE 0276-603

NYCY — Standard Execution

Built to DIN VDE 0276-603 with stranded copper conductor and pvc outer sheath

NYCY — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per DIN VDE 0276-603

NYCY — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0276-603. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
0.6/1 kV (DIN VDE 0276-603)
Conductor construction
Stranded copper conductor — High-conductivity copper conductor per DIN VDE 0276-603
Primary insulation / dielectric
PVC core insulation — Extruded PVC dielectric (individual core / group layer)

Thermal

Continuous operating temperature
−30…+70 °C per DIN VDE 0276-603
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
PVC outer sheath — Extruded PVC outer sheath protective layer (continuous layer)
Minimum bending radius
12 × OD (installed / static routing)
Layer count & geometry
6 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with DIN VDE 0276-603
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
DIN VDE 0276-603
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
NYCY
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard NYCY cable sizes

Manufactured to DIN VDE 0276-603 across standard single-core and multi-core cross-sections.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
NYCY Standard Production Schedule (0.6/1 kV · −30…+70 °C)
NYCY 3G1.53 × 1.5 mm²8.410568
NYCY 4G1.54 × 1.5 mm²9.212874
NYCY 5G1.55 × 1.5 mm²10.115681
NYCY 3G2.53 × 2.5 mm²9.814878
NYCY 4G2.54 × 2.5 mm²10.818686
NYCY 5G2.55 × 2.5 mm²11.922895
NYCY 4G44 × 4.0 mm²12.6268101
NYCY 4G64 × 6.0 mm²14.2365114
NYCY 4G104 × 10 mm²17.5580140
NYCY 4G164 × 16 mm²20.4845163
NYCY 4G254 × 25 mm²24.81,290198
NYCY 4G354 × 35 mm²27.91,710223
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Single-core and multi-core sizes from 0.5 mm² up to 630 mm² (or AWG/kcmil) available per DIN VDE 0276-603.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (DIN VDE 0276-603)DC resistance at 20 °C and geometry within DIN VDE 0276-603 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (DIN VDE 0276-603)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (DIN VDE 0276-603)Full compliance with DIN VDE 0276-603 across −30…+70 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0276-603 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX NYCY <size> DIN VDE 0276-603 0.6/1 kV CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define NYCY (NYCY 0.6/1 kV PVC Power & Control Cable with Concentric Copper Wire & Counter-Helix Screen)?
NYCY (NYCY 0.6/1 kV PVC Power & Control Cable with Concentric Copper Wire & Counter-Helix Screen) is manufactured in accordance with DIN VDE 0276-603 for 0.6/1 kV service over -30 °C to +70 °C. Its 6-layer construction comprises stranded copper conductor, pvc core insulation, butyl/pvc filler bedding, concentric copper wire screen, copper tape, pvc outer sheath.
What is the minimum bending radius and installation temperature for NYCY?
The minimum installed bending radius for NYCY is 12 × OD across its continuous operating temperature range of -30 °C to +70 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of NYCY arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper conductor (High-conductivity copper conductor per DIN VDE 0276-603); (02) PVC core insulation (Extruded PVC dielectric (individual core / group layer)); (03) Butyl/PVC filler bedding (Extruded Butyl/PVC filler bedding protective layer (continuous layer)); (04) Concentric copper wire screen (Concentric copper wire screen metallic electromagnetic screen (helically applied wires)); (05) Copper tape (Copper tape metallic electromagnetic screen (lapped tape)); (06) PVC outer sheath (Extruded PVC outer sheath protective layer (continuous layer)).
What factory test certificates are supplied with NYCY?
Every production drum or spool of NYCY undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per DIN VDE 0276-603, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for NYCY

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

NYCY 0.6/1 kV PVC Power & Control Cable with Concentric Copper Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote