Immersion & wet locations
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Product
SMPVG-100 / SMPEVG-100 & KVDN-630 (6–63 MPa) Hermetic Submarine Cable (TU 16.K71-106-90 & TU 0293-002 (6–63 MPa) Hermetic Submarine) engineered for 0.6/1 kV service across -40 °C to +70 °C (min. bend radius 10 × OD).
Typical values for this cable type, based on TU 16.K71-106-90 & TU 0293-002 (6–63 MPa) Hermetic Submarine — confirmed in the datasheet and quotation for your order.
Application fit
SMPVG-100 / SMPEVG-100 & KVDN-630 (6–63 MPa) Hermetic Submarine Cable (TU 16.K71-106-90 & TU 0293-002 (6–63 MPa) Hermetic Submarine) engineered for 0.6/1 kV service across -40 °C to +70 °C (min. bend radius 10 × OD).
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.
Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.
Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.
Outboard marine and feeder construction is not designed for high-speed crane festoon trolleys.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: SMPVG-100 / SMPEVG-100 & KVDN-630 (TU 16.K71-106-90 & TU 0293-002 (6–63 MPa) Hermetic Submarine) featuring hermetically sealed conductors, hdpe / rubber core insulation and inner sheath, overall braid & jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Hermetically Sealed Conductors | Class 3/4 stranded copper with inter-strand longitudinal pressure sealant |
| 2 | HDPE / Rubber Core Insulation | High-density polyethylene (СМПВГ/СМПЭВГ, up to 5 kV AC) or rubber (КВДН) |
| 3 | Individual Copper Screen & PE Sheath | Soft copper wire screen + extruded PE isolation sheath on each core (СМПЭВГ) |
| 4 | 10–63 MPa Hermetic Interstice Compound | High-pressure elastomeric sealing compound injected into 100% of cable voids |
| 5 | Inner Sheath, Overall Braid & Jacket | Inner sheath + copper braid shield + oil/seawater-resistant FR-PVC or PCP jacket |
Built to TU 16.K71-106-90 & TU 0293-002 (6–63 MPa) Hermetic Submarine with hermetically sealed conductors and inner sheath, overall braid & jacket
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to TU 16.K71-106-90 & TU 0293-002 (6–63 MPa) Hermetic Submarine for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| SMPVG-100 / SMPEVG-100 & KVDN-630 Construction Schedule (−40…+70 °C) | |||||||
| SMPVG-100 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| SMPVG-100 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| SMPVG-100 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 0.6/1 kV (45–100 Ω data) | −40…+70 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 0.6/1 kV (45–100 Ω data) | −40…+70 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 0.6/1 kV (High-Power Hybrid) | −40…+70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (TU 16.K71-106-90 & TU 0293-002 (6–63 MPa) Hermetic Submarine) | DC resistance at 20 °C / optical attenuation and outer diameter within TU 16.K71-106-90 & TU 0293-002 (6–63 MPa) Hermetic Submarine tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (TU 16.K71-106-90 & TU 0293-002 (6–63 MPa) Hermetic Submarine) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (TU 16.K71-106-90 & TU 0293-002 (6–63 MPa) Hermetic Submarine) | Verified submersion integrity, tensile load and thermal stability across −40…+70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.