Offshore platform & shipboard deck trays
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Product
EBS1S / EBU1S & WB/WA/WE Series 0.6/1 kV (BS 6883 / UKOOA Code) GP4 EPR-Insulated GSWB/TPBWB-Armoured & Unarmoured Type SW4 LSZH Offshore Power & Control Cable (BS 6883 / UKOOA, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series) — confirmed in the datasheet and quotation for your order.
Application fit
EBS1S / EBU1S & WB/WA/WE Series 0.6/1 kV (BS 6883 / UKOOA Code) GP4 EPR-Insulated GSWB/TPBWB-Armoured & Unarmoured Type SW4 LSZH Offshore Power & Control Cable (BS 6883 / UKOOA, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.
Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.
Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.
Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA) (BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series)) featuring tinned copper conductors (4g35 mm²), bs 7655 gp4 epr insulation (e) and type sw4 outer sheath (1s - 0.6/1 kv) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Tinned Copper Conductors (4G35 mm²) | BS EN 60228 Class 2 / Class 5 tinned annealed copper conductors |
| 2 | BS 7655 GP4 EPR Insulation (E) | 90 °C high-grade ethylene-propylene rubber core insulation |
| 3 | Type SW4 Elastomeric Inner Bedding (B) | Halogen-free low-smoke oil-resistant cross-linked inner sheath |
| 4 | Galvanized Steel Wire Braid (S - GSWB) | High-tensile galvanized steel wire braid mechanical armour |
| 5 | Type SW4 Outer Sheath (1S - 0.6/1 kV) | Black BS 7655 SW4 flame-retardant oil-resistant offshore jacket |
Built to BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series) with tinned copper conductors (4g35 mm²) and type sw4 outer sheath (1s - 0.6/1 kv)
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series) for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA) Construction Schedule (−40…+90 °C) | |||||||
| EBS1S 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (4G16) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 3.8 | 135 | |
| EBS1S 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (4G35) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 7.4 | 175 | |
| EBS1S 3×70+1G35 mm² | 3 × 70 + 1G35 mm² (4G70) | IEC 60228 Class 2/5 Cu/SnCu | 38.2 | 3,260 | 14.8 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (4G16) | 1.15 | 0.6/1 kV (98 A) | −40…+90 °C |
| 3 × 35 + 1G16 mm² (4G35) | 0.52 | 0.6/1 kV (158 A) | −40…+90 °C |
| 3 × 70 + 1G35 mm² (4G70) | 0.27 | 0.6/1 kV (245 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series)) | DC resistance at 20 °C / optical attenuation and outer diameter within BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series) tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series)) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series)) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.