Contact
shipboard & offshore power cableBS 6883 / UKOOA0.6/1 kV (-40 to +90 °C)Type SW4 Outer Sheath (1S - 0.6/1 kV

EBS1S / EBU1S & WB/WA Series 0.6/1 kV BS 6883 UKOOA Offshore Power & Control CableBS 6883 / UKOOA — 0.6/1 kV — -40 to +90 °C Marine & Offshore Cable

EBS1S / EBU1S & WB/WA/WE Series 0.6/1 kV (BS 6883 / UKOOA Code) GP4 EPR-Insulated GSWB/TPBWB-Armoured & Unarmoured Type SW4 LSZH Offshore Power & Control Cable (BS 6883 / UKOOA, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).

Flame-retardant
Ozone, UV & moisture
Oil-resistant
Approved
Order designation
EBS1S 3×16+1G16 mm²
Outer Ø ≈
22.4 mm
Net weight ≈
920 kg/km
Tensile rating ≈
3.8 kN
Core / stranding
IEC 60228 Class 2/5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per BS 6883 / UKOOA
Operating temp.
−40…+90 °C
Continuous shipboard & offshore service
Min. bend radius
6 × OD
Marine tray, bulkhead & deck routing
Core / conductor
Tinned Copper Co
BS EN 60228 Class 2 / Class 5 tinned ann
Outer protection
Type SW4 Outer S
Black BS 7655 SW4 flame-retardant oil-re
Standard
BS 6883 / UKOOA
BS 6883:1999 & UKOOA Code EBS1S / EBU1S

Typical values for this cable type, based on BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series) — confirmed in the datasheet and quotation for your order.

Application fit

Is EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA) right for your machine?

EBS1S / EBU1S & WB/WA/WE Series 0.6/1 kV (BS 6883 / UKOOA Code) GP4 EPR-Insulated GSWB/TPBWB-Armoured & Unarmoured Type SW4 LSZH Offshore Power & Control Cable (BS 6883 / UKOOA, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).

Offshore platform & shipboard deck trays

Suitable

Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.

Fixed installation

Suitable

Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.

Drilling jumbo & rotary mast feed

Suitable

Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.

Motor stator, traction & converter leads

Suitable

Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.

Energy chain / drag chain

Not suitable

Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableCommercial Vessels & Cruise ShipsOffshore Oil & Gas Platforms (FPSO)Jack-Up & Semi-Submersible Drilling RigsNaval Surface Vessels & Submarines

Construction

Layer by layer

Shown: EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA) (BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series)) featuring tinned copper conductors (4g35 mm²), bs 7655 gp4 epr insulation (e) and type sw4 outer sheath (1s - 0.6/1 kv) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Tinned Copper Conductors (4G35 mm²)BS EN 60228 Class 2 / Class 5 tinned annealed copper conductors
2BS 7655 GP4 EPR Insulation (E)90 °C high-grade ethylene-propylene rubber core insulation
3Type SW4 Elastomeric Inner Bedding (B)Halogen-free low-smoke oil-resistant cross-linked inner sheath
4Galvanized Steel Wire Braid (S - GSWB)High-tensile galvanized steel wire braid mechanical armour
5Type SW4 Outer Sheath (1S - 0.6/1 kV)Black BS 7655 SW4 flame-retardant oil-resistant offshore jacket

EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA) — Standard Shipboard & Offshore Execution

Built to BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series) with tinned copper conductors (4g35 mm²) and type sw4 outer sheath (1s - 0.6/1 kv)

EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA) — Custom Drum Length & Gland Kit

Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands

EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA) — Class & Routine Test Certified

Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series). Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series))
Core / conductor construction
Tinned Copper Conductors (4G35 mm²) — BS EN 60228 Class 2 / Class 5 tinned annealed copper conductors
Primary dielectric / buffering
BS 7655 GP4 EPR Insulation (E) — 90 °C high-grade ethylene-propylene rubber core insulation

Thermal

Continuous operating temperature
−40…+90 °C (shipboard & offshore duty)
Short-circuit / peak thermal rating
Verified thermal stability per BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series)
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Type SW4 Outer Sheath (1S - 0.6/1 kV) — Black BS 7655 SW4 flame-retardant oil-resistant offshore jacket
Minimum bending radius
6 × OD
Armour, screen & mechanical duty
Galvanized Steel Wire Braid (S - GSWB) — High-tensile galvanized steel wire braid mechanical armour

Resistance

Flame, fire & smoke performance
Qualified for marine flame-retardance and low-smoke zero-halogen / fire safety per BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series)
Oil, drilling mud & seawater resistance
Resistant to marine fuel/lube oils, salt mist and offshore fluids per BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series)
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series)
Environmental & test standards
IEC 60228 / IEC 60332-3-22 / IEC 60754 / IEC 61034 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA)
Sheath colour & metre marking
Continuous metre-marked black outer finish (Type SW4 Outer S)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA) shipboard & offshore configurations

Manufactured to BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series) for shipboard, offshore platform, drilling rig and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA) Construction Schedule (−40…+90 °C)
EBS1S 3×16+1G16 mm²3 × 16 + 1G16 mm² (4G16)IEC 60228 Class 2/5 Cu/SnCu22.49203.8135
EBS1S 3×35+1G16 mm²3 × 35 + 1G16 mm² (4G35)IEC 60228 Class 2/5 Cu/SnCu28.81,6907.4175
EBS1S 3×70+1G35 mm²3 × 70 + 1G35 mm² (4G70)IEC 60228 Class 2/5 Cu/SnCu38.23,26014.8230
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series).

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series))DC resistance at 20 °C / optical attenuation and outer diameter within BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series) tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series))Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Flame, fire integrity, oil/mud & mechanical qualification (BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series))Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

BS 6883 / UKOOA CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA) BS 6883 / UKOOA 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel marine reels
Standard lengths
500 m, 1,000 m or custom continuous shipboard/offshore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA) (EBS1S / EBU1S & WB/WA Series 0.6/1 kV BS 6883 UKOOA Offshore Power & Control Cable)?
EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA) (EBS1S / EBU1S & WB/WA Series 0.6/1 kV BS 6883 UKOOA Offshore Power & Control Cable) is manufactured in accordance with BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series) for 0.6/1 kV service over -40 to +90 °C. Its 5-layer construction comprises tinned copper conductors (4g35 mm²), bs 7655 gp4 epr insulation (e) and type sw4 outer sheath (1s - 0.6/1 kv).
What is the minimum bending radius and operating temperature range for EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA)?
The minimum bending radius for EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA) is 6 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical and dielectric reliability in shipboard and offshore service.
How are the concentric layers of EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA) arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Tinned Copper Conductors (4G35 mm²) — BS EN 60228 Class 2 / Class 5 tinned annealed copper conductors; (02) BS 7655 GP4 EPR Insulation (E) — 90 °C high-grade ethylene-propylene rubber core insulation; (03) Type SW4 Elastomeric Inner Bedding (B) — Halogen-free low-smoke oil-resistant cross-linked inner sheath; (04) Galvanized Steel Wire Braid (S - GSWB) — High-tensile galvanized steel wire braid mechanical armour; (05) Type SW4 Outer Sheath (1S - 0.6/1 kV) — Black BS 7655 SW4 flame-retardant oil-resistant offshore jacket.
What factory test certificates are supplied with EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA)?
Every production drum of EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA) undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per BS 6883:1999 & UKOOA Code EBS1S / EBU1S (WB/WA/WE Series), and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for EBS1S / EBU1S & WB/WA 0.6/1 KV (BS 6883 UKOOA)

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

EBS1S / EBU1S & WB/WA Series 0.6/1 kV BS 6883 UKOOA Offshore Power & Control Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote