Immersion & wet locations
Submarine armoured PE/PP builds and AD8 submersible jackets withstand seabed burial, wave catenaries and continuous seawater immersion.
Product
SOFC Submarine Optical Fiber & Power Composite Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (IEC 60502-2 / ITU-T G.652, 0.6/1 kV – 6/10 kV, -20 to +90 °C, min. bend radius 12 × OD).
Typical values for this cable type, based on IEC 60502-2 & ITU-T G.652.D SOFC Submarine Optical-Power Composite Standard — confirmed in the datasheet and quotation for your order.
Application fit
SOFC Submarine Optical Fiber & Power Composite Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (IEC 60502-2 / ITU-T G.652, 0.6/1 kV – 6/10 kV, -20 to +90 °C, min. bend radius 12 × OD).
Submarine armoured PE/PP builds and AD8 submersible jackets withstand seabed burial, wave catenaries and continuous seawater immersion.
IEC 60502-1/-2 and IEC 60092-353 constructions install across shore landings, inter-cage subsea grids and shipboard cable trays.
Resistant to seawater, diesel oil, UV weathering and mechanical impact on floating aquaculture collars and port quaysides.
Dynamic aquaculture catenary and flexible shore-power builds absorb tidal rise, vessel heave and pontoon motion.
Submarine armoured feeders and shipboard power cables are not designed for high-cycle automated drag chains.
Use FD 855 P Drag-Chain CableConstruction
Shown: SOFC Submarine Optical-Power Cable (IEC 60502-2 & ITU-T G.652.D SOFC Submarine Optical-Power Composite Standard) featuring single-mode / multi-mode optical unit, power & control copper conductors and subsea / marine outer protective sheath (3-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Single-Mode / Multi-Mode Optical Unit | Hermetic stainless-steel tube / tight-buffered optical unit |
| 2 | Power & Control Copper Conductors | Stranded copper conductors with Cross-linked polyethylene (XLPE) insulation |
| 3 | Subsea / Marine Outer Protective Sheath | Black heavy-duty submersible elastomeric outer sheath |
Built to IEC 60502-2 & ITU-T G.652.D SOFC Submarine Optical-Power Composite Standard with single-mode / multi-mode optical unit and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to IEC 60502-2 & ITU-T G.652.D SOFC Submarine Optical-Power Composite Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| SOFC Submarine Optical-Power Cable Construction Schedule (−20…+90 °C) | |||||||
| SOFC Submarine Optical-Power Cable Hybrid 4G2.5+ | 4G2.5 mm² Power + 4×SM + 2×2×0.5 | Class 5 SnCu + Aramid Braid + Subsea PUR | 14.6 | 285 | 18.0 | 90 | |
| SOFC Submarine Optical-Power Cable Hybrid 4G6+FO | 4G6.0 mm² Power + 4×SM/MM + 4×2×0.5 | Class 5 SnCu + Aramid Braid + Subsea PUR | 19.2 | 540 | 32.0 | 120 | |
| SOFC Submarine Optical-Power Cable Hybrid 4G16+F | 4G16 mm² Power + 8×SM/MM + 4×2×0.75 | Class 5 SnCu + Heavy Aramid + Subsea PUR | 26.5 | 1,120 | 55.0 | 165 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 4G2.5 mm² Power + 4×SM + 2×2×0.5 | 7.98 | 0.6/1 kV – 6/10 kV · 18 kN Tensile | −20…+90 °C |
| 4G6.0 mm² Power + 4×SM/MM + 4×2×0.5 | 3.30 | 0.6/1 kV – 6/10 kV · 32 kN Tensile | −20…+90 °C |
| 4G16 mm² Power + 8×SM/MM + 4×2×0.75 | 1.21 | 0.6/1 kV – 6/10 kV · 55 kN Tensile | −20…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (IEC 60502-2 & ITU-T G.652.D SOFC Submarine Optical-Power Composite Standard) | DC resistance at 20 °C, optical attenuation and wall thickness within IEC 60502-2 & ITU-T G.652.D SOFC Submarine Optical-Power Composite Standard limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (IEC 60502-2 & ITU-T G.652.D SOFC Submarine Optical-Power Composite Standard) | Zero dielectric breakdown and verified wet insulation resistance for 0.6/1 kV – 6/10 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (IEC 60502-2 & ITU-T G.652.D SOFC Submarine Optical-Power Composite Standard) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −20…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking