Typical values for this cable type, based on Reference specification per EN 50264-3-2 MMS / EN 45545-2 HL3 (RMM2C35 600/1000V EN 50264-3-2 MMS) — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Approved for open cable tray, raceway and supported industrial runs per standard installation rules.
Fine-stranded copper conductors withstand routine equipment vibration and occasional flexing.
Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.
Low-smoke zero-halogen outer sheath minimizes toxic acid gas emission and smoke obscuration in fire events.
Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.
Use TRA 0.6/1 kV PUR Reeling CableLow-toxicity fire-safe 0.6/1 kV construction fits railcar underframes, bogie jumpers, and enclosed passenger coach conduits.
Construction
Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

| # | Layer | Material & reference |
|---|---|---|
| 1 | 2×35 mm² Class 5 Tinned Copper | IEC 60228 Class 5 Flexible Stranded Tinned Copper |
| 2 | Cross-Linked Polyolefin (XLPO) Insulation | Ø9.80 mm EI 109 Halogen-Free Cross-Linked Polyolefin |
| 3 | 80% Coverage Tinned Copper Wire Braid Shield | EN 50264-3-2 MMS 80% Braided EMC Shield |
| 4 | Black EN 45545-2 HL3 XLPO Outer Jacket | EM 104 Halogen-Free Cross-Linked Sheath (23.50 mm OD) |
IEC 60228 Class 5 Tinned Cu + EI 109 + 80% TCWB + EM 104 · Outer diameter 23.5 mm.
IEC 60228 Class 5 Tinned Cu + EI 109 + 80% TCWB + EM 104 · Outer diameter 16.8 mm.
IEC 60228 Class 5 Tinned Cu + EI 109 + 80% TCWB + EM 104 · Outer diameter 20.1 mm.
Technical data
Sizes
Representative configurations from the series specification; select a row to prefill the quotation tool.
| Configuration | Conductor & shield | Insulation / wall | Outer sheath | Outer diameter mm | Min. bend radius mm | Max. conductor resistance @ 20 °C Ω/km | Copper weight kg/km | Cable weight kg/km | Key electrical / optical rating | Part designation | Enquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| RMM2C35 600/1000V EN 50264-3-2 MMS | |||||||||||
| 2 × 35 mm² (EN 50264-3-2 0.6/1 kV M) | IEC 60228 Class 5 Tinned Cu + EI 109 + 80% TCWB + EM 104 | Ø9.80 mm EI 109 Halogen-Free Cross-Linked Polyolefin | LSZH Jacket | 23.5 | 141 | 0.57 | 742.0 | 985 | 0.6/1 kV AC / 0.9/1.5 kV DC · EN 45545-2 HL3 | RMM2C35 EN 50264-3-2 2×35 mm² MMS | |
| 2 × 16 mm² (EN 50264-3-2 0.6/1 kV M) | IEC 60228 Class 5 Tinned Cu + EI 109 + 80% TCWB + EM 104 | Ø9.80 mm EI 109 Halogen-Free Cross-Linked Polyolefin | LSZH Jacket | 16.8 | 101 | 1.24 | 358.0 | 495 | 0.6/1 kV AC / 0.9/1.5 kV DC · EN 45545-2 HL3 | RMM2C16 EN 50264-3-2 2×16 mm² MMS | |
| 2 × 25 mm² (EN 50264-3-2 0.6/1 kV M) | IEC 60228 Class 5 Tinned Cu + EI 109 + 80% TCWB + EM 104 | Ø9.80 mm EI 109 Halogen-Free Cross-Linked Polyolefin | LSZH Jacket | 20.1 | 121 | 0.80 | 545.0 | 725 | 0.6/1 kV AC / 0.9/1.5 kV DC · EN 45545-2 HL3 | RMM2C25 EN 50264-3-2 2×25 mm² MMS | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & continuity | Within maximum Ω/km limit at 20 °C | Every manufactured drum length |
| Dielectric withstand / spark test | No breakdown across insulation or shield | Every manufactured drum length |
| Sample tests | ||
| Vertical flame propagation & jacket qualification | Self-extinguishing within standard char limit | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.