Contact

RMM2C35 EN 50264-3-2 600/1000V 2×35 mm² MMS Rolling Stock Power CableEN 50264-3-2 MMS & EN 45545-2 HL3 (0.6/1 kV AC, -40 to +120 °C) 2×35 mm² tinned copper EI 109 XLPO insulated, 80% braided and EM 104 halogen-free rolling stock power cable.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

EMC screen
Flame-retardant
Oil-resistant
Approved
Order designation
RMM2C35 EN 50264-3-2 2×35 mm² MMS
Outer diameter
23.5 mm
Cable weight
985 kg/km
Min. bend radius
141 mm
Conductor & shield
IEC 60228 Class 5 Tinned Cu + EI 109 + 80% TCWB + EM 104
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
EN 50264-3-2 MMS / EN 45545-2 HL3
Temperature
−40…+120 °C
Fixed / flex duty
Min. bend radius
6 × OD
20.1–23.5 mm
Screening
TC Braid
≥ 80%–85% tinned Cu braid
Outer sheath
LSZH Jacket
Halogen-free fire-safety corridors
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per EN 50264-3-2 MMS / EN 45545-2 HL3 (RMM2C35 600/1000V EN 50264-3-2 MMS) — confirmed in the datasheet and quotation for your order.

Application fit

Is RMM2C35 600/1000V EN 50264-3-2 MMS right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for open cable tray, raceway and supported industrial runs per standard installation rules.

Motor stator, traction & converter leads

Suitable

Fine-stranded copper conductors withstand routine equipment vibration and occasional flexing.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

TBM gantry & advancing tunnel reel

Suitable

Low-smoke zero-halogen outer sheath minimizes toxic acid gas emission and smoke obscuration in fire events.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Railcar bogie & underframe harness

Suitable

Low-toxicity fire-safe 0.6/1 kV construction fits railcar underframes, bogie jumpers, and enclosed passenger coach conduits.

Typical machinesRailway & TransitIndustrial automation & control cabinetsInverter-fed motor drive systemsProcess instrumentation & oil/gas skidsMachine tools & robotic cellsData centers, stadiums & broadcast facilities

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

RMM2C35 600/1000V EN 50264-3-2 MMS – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
12×35 mm² Class 5 Tinned CopperIEC 60228 Class 5 Flexible Stranded Tinned Copper
2Cross-Linked Polyolefin (XLPO) InsulationØ9.80 mm EI 109 Halogen-Free Cross-Linked Polyolefin
380% Coverage Tinned Copper Wire Braid ShieldEN 50264-3-2 MMS 80% Braided EMC Shield
4Black EN 45545-2 HL3 XLPO Outer JacketEM 104 Halogen-Free Cross-Linked Sheath (23.50 mm OD)

2 × 35 mm² (EN 50264-3-2 0.6/1 kV M)

IEC 60228 Class 5 Tinned Cu + EI 109 + 80% TCWB + EM 104 · Outer diameter 23.5 mm.

2 × 16 mm² (EN 50264-3-2 0.6/1 kV M)

IEC 60228 Class 5 Tinned Cu + EI 109 + 80% TCWB + EM 104 · Outer diameter 16.8 mm.

2 × 25 mm² (EN 50264-3-2 0.6/1 kV M)

IEC 60228 Class 5 Tinned Cu + EI 109 + 80% TCWB + EM 104 · Outer diameter 20.1 mm.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per EN 50264-3-2 MMS / EN 45545-2 HL3 (RMM2C35 600/1000V EN 50264-3-2 MMS). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
0.6/1 kV
Conductor & core insulation
IEC 60228 Class 5 Flexible Stranded Tinned Copper · Ø9.80 mm EI 109 Halogen-Free Cross-Linked Polyolefin
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
−40…+120 °C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
EN 50264-3-2 MMS / EN 45545-2 HL3

Mechanical

Minimum bending radius
6 × OD
Screening / armour architecture
EN 50264-3-2 MMS 80% Braided EMC Shield
Outer sheath material & colour
EM 104 Halogen-Free Cross-Linked Sheath (23.50 mm OD)

Reference standards

Reference standard
EN 50264-3-2 / EN 50264-1 / EN 45545-2 HL1–HL3 / IEC 60228 Class 5 / IEC 60754 / IEC 61034
Hazardous Substance Compliance
CE, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
RMM2C35 600/1000V EN 50264-3-2 MMS
2 × 35 mm² (EN 50264-3-2 0.6/1 kV M)IEC 60228 Class 5 Tinned Cu + EI 109 + 80% TCWB + EM 104Ø9.80 mm EI 109 Halogen-Free Cross-Linked PolyolefinLSZH Jacket23.51410.57742.09850.6/1 kV AC / 0.9/1.5 kV DC · EN 45545-2 HL3RMM2C35 EN 50264-3-2 2×35 mm² MMS
2 × 16 mm² (EN 50264-3-2 0.6/1 kV M)IEC 60228 Class 5 Tinned Cu + EI 109 + 80% TCWB + EM 104Ø9.80 mm EI 109 Halogen-Free Cross-Linked PolyolefinLSZH Jacket16.81011.24358.04950.6/1 kV AC / 0.9/1.5 kV DC · EN 45545-2 HL3RMM2C16 EN 50264-3-2 2×16 mm² MMS
2 × 25 mm² (EN 50264-3-2 0.6/1 kV M)IEC 60228 Class 5 Tinned Cu + EI 109 + 80% TCWB + EM 104Ø9.80 mm EI 109 Halogen-Free Cross-Linked PolyolefinLSZH Jacket20.11210.80545.07250.6/1 kV AC / 0.9/1.5 kV DC · EN 45545-2 HL3RMM2C25 EN 50264-3-2 2×25 mm² MMS
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °CEvery manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation or shieldEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing within standard char limitType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

EN 50264-3-2 MMS / EN 45545-2 HL3 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX RMM2C35 600/1000V EN 50264-3-2 MMS EN 50264-3-2 MMS / EN 45545-2 HL3 0.6/1 kV CE ROHS — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
305 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-03
Updated
2026-11-03

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is RMM2C35 600/1000V EN 50264-3-2 MMS designed for?
RMM2C35 600/1000V EN 50264-3-2 MMS is engineered for industrial installations under EN 50264-3-2 MMS / EN 45545-2 HL3, operating over −40…+120 °C with a minimum bending radius of 6 × OD.
How does the construction of RMM2C35 600/1000V EN 50264-3-2 MMS protect signal and power integrity?
Its multi-layer build combines 2×35 mm² Class 5 Tinned Copper with Cross-Linked Polyolefin (XLPO) Insulation and Black EN 45545-2 HL3 XLPO Outer Jacket to ensure mechanical stability and electrical performance.
What standards and fire ratings apply to RMM2C35 600/1000V EN 50264-3-2 MMS?
The cable is qualified to EN 50264-3-2 / EN 50264-1 / EN 45545-2 HL1–HL3 / IEC 60228 Class 5 / IEC 60754 / IEC 61034, meeting vertical flame propagation and industrial jacket durability requirements.
Can RMM2C35 600/1000V EN 50264-3-2 MMS be supplied in custom lengths or configurations?
Yes. Standard configurations include RMM2C35 EN 50264-3-2 2×35 mm² MMS, RMM2C16 EN 50264-3-2 2×16 mm² MMS and RMM2C25 EN 50264-3-2 2×25 mm² MMS, supplied on 305 m, 500 m or 1,000 m export drums.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for RMM2C35 600/1000V EN 50264-3-2 MMS

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

RMM2C35 600/1000V EN 50264-3-2 MMS RMM2C35 EN 50264-3-2 600/1000V 2×35 mm² MMS Rolling Stock Power Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp