Fire-resistant & alarm cables

Circuit-integrity power cables, screened fire alarm cables, mineral-insulated copper cables and linear heat detection cables that maintain operation during fire.

How does the cable move?

Pick one or more duties — the list below updates.

18 fire-resistant & alarm cables

Voltage
Standard
Sheath
Features

Fire-resistant power cables

NHXH, NHXCH, BS 7846, BS 7917 offshore and mineral-insulated EN 60702-1 emergency power feeders.

6 cables
NHXCH — cable cross-section
NHXCHNHXCH Fire-Resistant Cable with Concentric Conductor
0.6/1 kV
Fixed, control cabinet
IECHalogen-free
0.6/1 kV, IEC, Halogen-free sheathFixed, control cabinet
NHXH — cable cross-section
NHXHNHXH Halogen-Free Fire-Resistant Power Cable
0.6/1 kV
Fixed, control cabinet
DIN VDEHalogen-free
0.6/1 kV, DIN VDE, Halogen-free sheathFixed, control cabinet
BS 7846 — cable cross-section
BS 7846BS 7846 Armoured Fire-Resistant Power Cable
0.6/1 kV
Fixed, control cabinet
BSHalogen-free
0.6/1 kV, BS, Halogen-free sheathFixed, control cabinet
BS 7917 A FR — cable cross-section
BS 7917 A FRBS 7917 A FR Armoured Fire-Resistant Offshore Power Cable
0.6/1 kV
Fixed, offshore & shipboard
BSHalogen-free
0.6/1 kV, BS, Halogen-free sheathFixed, offshore & shipboard
BS 7917 U FR — cable cross-section
BS 7917 U FRBS 7917 U FR Unarmoured Fire-Resistant Offshore Power Cable
0.6/1 kV
Fixed, offshore & shipboard
BSHalogen-free
0.6/1 kV, BS, Halogen-free sheathFixed, offshore & shipboard
BS EN 60702-1 — cable cross-section
BS EN 60702-1BS EN 60702-1 Mineral-Insulated Metal-Sheathed Power Cable
0.6/1 kV
Fixed, control cabinet
EN / HDHalogen-free
0.6/1 kV, EN / HD, Halogen-free sheathFixed, control cabinet

Fire alarm & heat detection

BS 7629-1 screened alarm cables, FPLP/FPLR riser and plenum cables and linear heat detection cables.

12 cables
A-H(L)HBH — cable cross-section
A-H(L)HBHA-H(L)HBH LSZH Armoured Outdoor Signalling Cable
300/500 V
Fixed, control cabinet
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, control cabinet
A-HHBH — cable cross-section
A-HHBHA-HHBH Halogen-Free Steel-Tape Armoured Signalling Cable
300/500 V
Fixed, control cabinet
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, control cabinet
BS 7629-1 — cable cross-section
BS 7629-1BS 7629-1 Screened Fire-Resistant Alarm Cable
300/500 V
Fixed, control cabinet
BSHalogen-free
300/500 V, BS, Halogen-free sheathFixed, control cabinet
Fire-Resistant FO FE180 — Fire-Resistant FO FE180 Circuit-Integrity Fibre Optic Cable
Fire-Resistant FO FE180Fire-Resistant FO FE180 Circuit-Integrity Fibre Optic Cable
300/500 V
Fixed, control cabinet
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, control cabinet
FPLP — cable cross-section
FPLPFPLP Plenum Fire Alarm Cable
300/500 V
Fixed, control cabinet
UL / CSAFluoropolymer
300/500 V, UL / CSA, Fluoropolymer sheathFixed, control cabinet
FPLR — cable cross-section
FPLRFPLR Riser Fire Alarm Cable
300/500 V
Fixed, control cabinet
UL / CSAPVC
300/500 V, UL / CSA, PVC sheathFixed, control cabinet
S07HXCHX-F — cable cross-section
S07HXCHX-FS07HXCHX-F Screened Halogen-Free Cross-Linked Elastomer Flexible
300/500 V
Fixed, control cabinet
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, control cabinet
S07HXHX — cable cross-section
S07HXHXS07HXHX Halogen-Free Cross-Linked Elastomer Flexible Power &
300/500 V
Fixed, control cabinet
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, control cabinet
Securiton SEC 15 / SEC 20 — cable cross-section
Securiton SEC 15 / SEC 20Securiton SEC 15 / SEC 20 Copper-Tube Sensing Element Linear Heat
300/500 V
Fixed, control cabinet
IECPE
300/500 V, IEC, PE sheathFixed, control cabinet
SS-LD — cable cross-section
SS-LDSS-LD Digital Linear Heat Detection Cable
300/500 V
Fixed, control cabinet
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, control cabinet
SS-LDN — cable cross-section
SS-LDNSS-LDN Nylon-Jacketed Linear Heat Detection Cable
300/500 V
Fixed, control cabinet
IECRubber
300/500 V, IEC, Rubber sheathFixed, control cabinet
SS-LDS — cable cross-section
SS-LDSSS-LDS Stainless-Steel-Protected Linear Heat Detection Cable
300/500 V
Fixed, control cabinet
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, control cabinet

Choosing fire-resistant & alarm cables

Four things decide most selections. Our engineers check the rest against your application.

Application and movement duty

  • Define whether the cable runs in a fixed tray, energy chain, festoon loop, reel or trailing route.
  • Match travel speed, bend radius and tensile load to the mechanical construction.
  • Select a support element or armour when the cable carries suspended weight or external crush loads.

Voltage class and core layout

  • Match the rated voltage U0/U to the supply system and earthing arrangement.
  • Specify phase cross-sections, protective earth, pilot cores or control pairs required by the machine.
  • Include copper braid, tape or semiconductive screens where EMC or electric-field control is needed.

Operating environment and sheath

  • Choose rubber, PUR, LSZH, PVC, fluoropolymer or silicone sheaths for the thermal and chemical exposure.
  • Verify oil, UV, water immersion, cold-flex or circuit-integrity ratings against site conditions.
  • Check outer diameter and gland compatibility at both terminations.

Standard and documentation

  • Confirm the governing standard family required by the project specification.
  • Verify conductor class, colour code or core numbering for the destination region.
  • Include operating duty and cable length in your enquiry so we can confirm the build.
Filter the range by standard

Questions buyers ask

Not covered here? Send your drawing and an engineer replies within 2 business hours.

Ask on WhatsApp
How do I select the right fire-resistant cable from this range?

Start by filtering the list by movement duty, voltage band and sheath material. Compare how each fire-resistant cable is constructed—conductor flexibility, insulation compound, screening and outer jacket—against your machine's bending radius, travel speed and ambient temperature. Open the product page or datasheet to check core counts, cross-sections and outer diameters before sending your enquiry.

When should fire-resistant & alarm cables include metallic screening or armour?

Specify a copper braid or foil screen when fire-resistant & alarm cables run near variable-frequency drives, carry analogue or fieldbus signals, or require medium-voltage electric-field control. Choose steel wire braid or armour when the installation faces rock fall, crushing loads or high pulling tension in roadways, decks or subsea routes.

Which outer sheath compound suits harsh industrial environments?

Heavy-duty rubber (PCP or CPE) provides balanced mechanical toughness, weather resistance and thermal stability. Polyurethane (PUR) resists cuts, abrasion and mineral oils on fast-moving chains, reels and trolleys. Halogen-free LSZH compounds reduce smoke and acid gas in tunnels, ships and enclosed buildings, while fluoropolymers and silicone handle extreme heat.

What details should I include in an RFQ for fire-resistant & alarm cables?

Include the model designation or governing standard, rated voltage, number of cores and conductor cross-sections, along with the installation method, minimum bend radius, ambient temperature range and required delivery lengths. If you are replacing an existing cable on a machine, share the sheath marking so we can match the specification.

Engineering reference

Background on how fire-resistant & alarm cables are built, rated and specified.

Read the full reference

Fire-resistant & alarm cables cover industrial constructions engineered for reliable electrical transmission under defined mechanical, thermal and environmental stresses. Selecting the right build requires matching conductor stranding, insulation system, screening and outer sheath compound to the actual installation route rather than relying on nominal cross-section alone.

Across the TEBAOFLEX fire-resistant & alarm cables portfolio, models are grouped into functional families so engineers can filter by duty, voltage band, standard family and jacket compound. Each construction addresses a specific balance of flexibility, dielectric strength, electromagnetic compatibility and resistance to oil, water, UV radiation or flame propagation.

Before finalizing a specification, verify the governing national or international standard, operating voltage U0/U, ambient temperature range and minimum bending radius in fixed or moving duty. Where cables interface with connectors, glands or motor terminal boxes, check nominal outer diameter and screen termination geometry early.

When submitting an RFQ for fire-resistant & alarm cables, specify the model designation, core count and cross-sections, system voltage, installation method, environmental exposure and required drum or assembly lengths so our engineering team can confirm the exact construction and datasheet.