UL 854 Type USE-2 / RHH / RHW-2 600 V Cross-Linked Polyethylene WireUL 854 / UL 44 / ICEA S-95-658 · 600 V · -40 °C to +90 °C industrial USE-2 construction

UL 854 Type USE-2 / RHH / RHW-2 600 V Cross-Linked Polyethylene Underground Service Wire (USE-2) engineered to UL 854 / UL 44 / ICEA S-95-658 for 600 V service across -40 °C to +90 °C, featuring stranded copper conductor and xlpe insulation with minimum

Approved
Outdoor & humid
Ozone, UV & moisture
Water-resistant
Order designation
USE-2 4G2.5
Outer Ø ≈
10.8 mm
Total weight ≈
186 kg/km
Min. bend R (fixed)
86 mm
Configuration
4 × 2.5 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Per UL 854 / UL 44 / ICEA S-95-658
Operating temp.
−40…+90 °C
Continuous thermal rating (UL 854)
Min. bend radius
6 × OD
Installed / fixed routing
Conductor
copper conductor
High-conductivity copper conductor
Outer layer
XLPE insulation
Extruded XLPE insulation dielectric
Standard
UL 854
UL 854 / UL 44 / ICEA S-95-658

Typical values for this cable type, based on UL 854 / UL 44 / ICEA S-95-658 — confirmed in the datasheet and quotation for your order.

Application fit

Is USE-2 right for your machine?

UL 854 Type USE-2 / RHH / RHW-2 600 V Cross-Linked Polyethylene Underground Service Wire (USE-2) engineered to UL 854 / UL 44 / ICEA S-95-658 for 600 V service across -40 °C to +90 °C, featuring stranded copper conductor and xlpe insulation with minimum

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with UL 854 / UL 44 / ICEA S-95-658.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 6 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesBuilding & Fire SafetyCommercial & Residential Building DistributionData Centers & Public InfrastructureFire-Safe Evacuation & Riser ShaftsIndustrial Plant Balance-of-Plant WiringHigh-Voltage Grid & Substation Interconnects

Construction

Layer by layer

Shown: USE-2 (UL 854 / UL 44 / ICEA S-95-658) with stranded copper conductor, xlpe insulation and xlpe insulation (2-layer construction).

12
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper conductorHigh-conductivity copper conductor per UL 854 / UL 44 / ICEA S-95-658UL 854 / UL 44 / ICEA S-95-658
2XLPE insulationExtruded XLPE insulation dielectric (continuous layer)UL 854 / UL 44 / ICEA S-95-658

USE-2 — Standard Execution

Built to UL 854 / UL 44 / ICEA S-95-658 with stranded copper conductor and xlpe insulation

USE-2 — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per UL 854 / UL 44 / ICEA S-95-658

USE-2 — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL 854 / UL 44 / ICEA S-95-658. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
600 V (UL 854 / UL 44 / ICEA S-95-658)
Conductor construction
Stranded copper conductor — High-conductivity copper conductor per UL 854 / UL 44 / ICEA S-95-658
Primary insulation / dielectric
XLPE insulation — Extruded XLPE insulation dielectric (continuous layer)

Thermal

Continuous operating temperature
−40…+90 °C per UL 854 / UL 44 / ICEA S-95-658
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
XLPE insulation — Extruded XLPE insulation dielectric (continuous layer)
Minimum bending radius
6 × OD (installed / static routing)
Layer count & geometry
2 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with UL 854 / UL 44 / ICEA S-95-658
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
UL 854 / UL 44 / ICEA S-95-658
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
USE-2
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard USE-2 cable sizes

Manufactured to UL 854 / UL 44 / ICEA S-95-658 across standard single-core and multi-core cross-sections.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
USE-2 Standard Production Schedule (600 V · −40…+90 °C)
USE-2 3G1.53 × 1.5 mm²8.410568
USE-2 4G1.54 × 1.5 mm²9.212874
USE-2 5G1.55 × 1.5 mm²10.115681
USE-2 3G2.53 × 2.5 mm²9.814878
USE-2 4G2.54 × 2.5 mm²10.818686
USE-2 5G2.55 × 2.5 mm²11.922895
USE-2 4G44 × 4.0 mm²12.6268101
USE-2 4G64 × 6.0 mm²14.2365114
USE-2 4G104 × 10 mm²17.5580140
USE-2 4G164 × 16 mm²20.4845163
USE-2 4G254 × 25 mm²24.81,290198
USE-2 4G354 × 35 mm²27.91,710223
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Single-core and multi-core sizes from 0.5 mm² up to 630 mm² (or AWG/kcmil) available per UL 854 / UL 44 / ICEA S-95-658.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (UL 854 / UL 44 / ICEA S-95-658)DC resistance at 20 °C and geometry within UL 854 / UL 44 / ICEA S-95-658 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (UL 854 / UL 44 / ICEA S-95-658)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (UL 854 / UL 44 / ICEA S-95-658)Full compliance with UL 854 / UL 44 / ICEA S-95-658 across −40…+90 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL 854 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX USE-2 <size> UL 854 600 V CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define USE-2 (UL 854 Type USE-2 / RHH / RHW-2 600 V Cross-Linked Polyethylene Underground Service Wire)?
USE-2 (UL 854 Type USE-2 / RHH / RHW-2 600 V Cross-Linked Polyethylene Underground Service Wire) is manufactured in accordance with UL 854 / UL 44 / ICEA S-95-658 for 600 V service over -40 °C to +90 °C. Its 2-layer construction comprises stranded copper conductor, xlpe insulation.
What is the minimum bending radius and installation temperature for USE-2?
The minimum installed bending radius for USE-2 is 6 × OD across its continuous operating temperature range of -40 °C to +90 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of USE-2 arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper conductor (High-conductivity copper conductor per UL 854 / UL 44 / ICEA S-95-658); (02) XLPE insulation (Extruded XLPE insulation dielectric (continuous layer)).
What factory test certificates are supplied with USE-2?
Every production drum or spool of USE-2 undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per UL 854 / UL 44 / ICEA S-95-658, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for USE-2

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

UL 854 Type USE-2 / RHH / RHW-2 600 V Cross-Linked Polyethylene Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote