Immersion & wet locations
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Product
MIL-DTL-24643/32, /33 & /36 Types LS2SWAU, LS2SWU, LS3SWU & LS3SWUS 600 V Watertight Individually Copper-Braid-Shielded Multi-Pair & Multi-Triad Shipboard/Submarine Cable (MIL-DTL-24643/33 & /36, 600 V, -30 °C to +105 °C).
Typical values for this cable type, based on MIL-DTL-24643/32, /33G & /36F Navy Watertight Standard — confirmed in the datasheet and quotation for your order.
Application fit
MIL-DTL-24643/32, /33 & /36 Types LS2SWAU, LS2SWU, LS3SWU & LS3SWUS 600 V Watertight Individually Copper-Braid-Shielded Multi-Pair & Multi-Triad Shipboard/Submarine Cable (MIL-DTL-24643/33 & /36, 600 V, -30 °C to +105 °C).
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.
Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.
Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.
Outboard marine and feeder construction is not designed for high-speed crane festoon trolleys.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: MIL-DTL-24643/33 & /36 (LS2SWU / LS3SWU) (MIL-DTL-24643/32, /33G & /36F Navy Watertight Standard) featuring watertight conductors (7×3×18 awg), triad / pair color code and cross-linked polyolefin jacket (xlpo) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Watertight Conductors (7×3×18 AWG) | 7-strand Class B longitudinally water-blocked copper conductors with 0.58 mm XLPE |
| 2 | Triad / Pair Color Code | Black, White & Red triads in LS3SWU/LS3SWUS (Black & White 75 Ω pairs in LS2SWU) |
| 3 | Individual Copper Braid & Sealed Tapes | Tin-coated copper braid shield + two sealed polyester tapes per triad/pair |
| 4 | Watertight Core & Double Overall Braid | Water-Blocking watertight fillers + double overall tin-coated copper braid (LS3SWUS) |
| 5 | Cross-Linked Polyolefin Jacket (XLPO) | Low-smoke zero-halogen cross-linked polyolefin outer sheath (600 V rated) |
Built to MIL-DTL-24643/32, /33G & /36F Navy Watertight Standard with watertight conductors (7×3×18 awg) and cross-linked polyolefin jacket (xlpo)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to MIL-DTL-24643/32, /33G & /36F Navy Watertight Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| MIL-DTL-24643/33 & /36 (LS2SWU / LS3SWU) Construction Schedule (−30…+105 °C) | |||||||
| MIL-DTL-24643 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| MIL-DTL-24643 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| MIL-DTL-24643 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 600 V (45–100 Ω data) | −30…+105 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 600 V (45–100 Ω data) | −30…+105 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 600 V (High-Power Hybrid) | −30…+105 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (MIL-DTL-24643/32, /33G & /36F Navy Watertight Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within MIL-DTL-24643/32, /33G & /36F Navy Watertight Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (MIL-DTL-24643/32, /33G & /36F Navy Watertight Standard) | Zero dielectric breakdown and verified insulation resistance for 600 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (MIL-DTL-24643/32, /33G & /36F Navy Watertight Standard) | Verified submersion integrity, tensile load and thermal stability across −30…+105 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.