Fixed installation
Designed around the specified installation; select supports, bend protection and terminations together.
Product
Three-phase downhole power connection for an electrical submersible pump. Select insulation, gas barriers and armour for the well fluids and thermal profile.
Typical values for this cable type, based on Order-specific design — confirmed in the datasheet and quotation for your order.
Application fit
Three-phase downhole power connection for an electrical submersible pump. Select insulation, gas barriers and armour for the well fluids and thermal profile.
Designed around the specified installation; select supports, bend protection and terminations together.
Depth, pressure, fluid and temperature must be specified for immersion service.
Support and allowable suspended load are determined for the actual cable construction.
Repeated bending needs separate fatigue data; a flexible construction alone does not establish a cycle rating.
Construction
Representative schematic; not to scale. The final core arrangement and dimensions follow the agreed drawing.

| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | Copper |
| 2 | Insulation | EPDM |
| 3 | Inner jacket | NBR or EPDM |
| 4 | Metallic armour | Steel tape armour |
Technical data
Sizes
Dimensions are typical reference values for the stated construction. Final values are confirmed with the order.
| Configuration | Voltage (kV) | Section (mm²) | Outer diameter (mm) | Weight (kg/km) | Enquiry |
|---|---|---|---|---|---|
| NBR inner jacket · 3 kV | |||||
| ESP NBR 3 kV 3x1 AWG | 3 | 42.4 | 35.0 | 2,581 | |
| ESP NBR 3 kV 3x2 AWG | 3 | 33.6 | 33.2 | 2,246 | |
| ESP NBR 3 kV 3x4 AWG | 3 | 21.2 | 29.8 | 1,735 | |
| ESP NBR 3 kV 3x6 AWG | 3 | 13.3 | 27.5 | 1,384 | |
| NBR inner jacket · 4 kV | |||||
| ESP NBR 4 kV 3x1 AWG | 4 | 42.4 | 34.3 | 2,653 | |
| ESP NBR 4 kV 3x2 AWG | 4 | 33.6 | 32.6 | 2,314 | |
| ESP NBR 4 kV 3x4 AWG | 4 | 21.2 | 29.1 | 1,794 | |
| ESP NBR 4 kV 3x6 AWG | 4 | 13.3 | 26.8 | 1,442 | |
| NBR inner jacket · 5 kV | |||||
| ESP NBR 5 kV 3x1 AWG | 5 | 42.4 | 35.2 | 2,725 | |
| ESP NBR 5 kV 3x2 AWG | 5 | 33.6 | 33.4 | 2,386 | |
| ESP NBR 5 kV 3x4 AWG | 5 | 21.2 | 30.0 | 1,858 | |
| ESP NBR 5 kV 3x6 AWG | 5 | 13.3 | 27.6 | 1,502 | |
| EPDM inner jacket · 3 kV | |||||
| ESP EPDM 3 kV 3x1 AWG | 3 | 42.4 | 35.0 | 2,547 | |
| ESP EPDM 3 kV 3x2 AWG | 3 | 33.6 | 33.2 | 2,217 | |
| ESP EPDM 3 kV 3x4 AWG | 3 | 21.2 | 29.8 | 1,710 | |
| ESP EPDM 3 kV 3x6 AWG | 3 | 13.3 | 27.5 | 1,367 | |
| EPDM inner jacket · 4 kV | |||||
| ESP EPDM 4 kV 3x1 AWG | 4 | 42.4 | 34.3 | 2,616 | |
| ESP EPDM 4 kV 3x2 AWG | 4 | 33.6 | 32.6 | 2,283 | |
| ESP EPDM 4 kV 3x4 AWG | 4 | 21.2 | 29.1 | 1,771 | |
| ESP EPDM 4 kV 3x6 AWG | 4 | 13.3 | 26.8 | 1,424 | |
| EPDM inner jacket · 5 kV | |||||
| ESP EPDM 5 kV 3x1 AWG | 5 | 42.4 | 35.2 | 2,672 | |
| ESP EPDM 5 kV 3x2 AWG | 5 | 33.6 | 33.4 | 2,351 | |
| ESP EPDM 5 kV 3x4 AWG | 5 | 21.2 | 30.0 | 1,833 | |
| ESP EPDM 5 kV 3x6 AWG | 5 | 13.3 | 27.6 | 1,483 | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.