Fixed installation
Durable 1000 V Cu-ETP geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.
Product
AC Bare Cu Rope 120–700 is a 7×7 extra-flexible uninsulated electrolytic bare copper rope conductor designed for maximum natural air-cooling convection on transformer expansion joints, furnace shunts, and heavy earthing.
Typical values for this cable type, based on DIN 46438 · IEC 60228 Class 6 · EN 13602 Cu-ETP — confirmed in the datasheet and quotation for your order.
Application fit
AC Bare Cu Rope 120–700 is a 7×7 extra-flexible uninsulated electrolytic bare copper rope conductor designed for maximum natural air-cooling convection on transformer expansion joints, furnace shunts, and heavy earthing.
Durable 1000 V Cu-ETP geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.
Compact 1000 V Cu-ETP profile routes cleanly inside dense switchgear enclosures, BESS racks, and high-current test benches.
Rugged 1000 V Cu-ETP construction handles stationary heavy-plant cable trenches, rolling-mill feeders, and industrial power bays.
Extra-flexible heat- and spatter-resistant 1000 V Cu-ETP build delivers low-drop current to welding tongs and shop floor leads.
1000 V Cu-ETP construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR1000 V Cu-ETP outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of AC Bare-Cu Rope 120-700: IEC 60228 Class 6 extra-flexible bare annealed copper, Uninsulated 7×7 rope-lay electrolytic bare copper (air-insulated), and Uninsulated bare electrolytic copper rope outer lay.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | IEC 60228 Class 6 extra-flexible bare annealed copperIEC 60228 Class 6 |
| 2 | Uninsulated outer weave / lay | Uninsulated bare electrolytic copper rope outer layDIN 46438 |
Uninsulated flexible bare copper construction for maximal natural air-cooling convection.
Technical data
Sizes
| Cross-section mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Copper index kg/km | Weight ≈ kg/km | Min. bend R 6×D mm |
|---|---|---|---|---|---|
| 1×120 mm² | 15.3 | 0.161 | 1,152 | 1,331 | 92 |
| 1×150 mm² | 17.1 | 0.129 | 1,440 | 1,662 | 103 |
| 1×185 mm² | 19.0 | 0.106 | 1,776 | 2,048 | 114 |
| 1×240 mm² | 21.7 | 0.080 | 2,304 | 2,656 | 130 |
| 1×300 mm² | 24.2 | 0.064 | 2,880 | 3,318 | 145 |
| 1×400 mm² | 28.0 | 0.049 | 3,840 | 4,422 | 168 |
| 1×500 mm² | 31.3 | 0.038 | 4,800 | 5,526 | 188 |
| 1×700 mm² | 37.0 | 0.027 | 6,720 | 7,734 | 222 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric withstand test | 3 kV AC without breakdown | Every manufactured length |
| Continuity & conductor DC resistance | Per IEC 60228 Class 6 at 20 °C | Every drum / assembly |
| Sample tests | ||
| Tensile, dimensional & pressure check | Rated -60 °C to +150 °C continuous | Per production lot |
| Environmental, thermal & mechanical qualification | 99.95% Electrolytic Cu-ETP · Max Air Convection Cooling | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.