VFD inverter to AC motor screened feeder
Three uninsulated bare grounds bonded along the 100% helical copper tape deliver ultra-low EMI impedance.
Product
Industrial 2,000 V UL 1277 Type TC-ER VFD tray cable with stranded bare copper conductors, heavy-wall 90 °C RHW-2 XLPE insulation, three symmetrical uninsulated bare copper grounds, 100% helical copper tape shield, and sunlight-resistant PVC jacket.
Typical values for this cable type, based on UL 1277 Type TC-ER · UL 44 RHW-2 · ICEA S-95-658 · IEEE 1202 — confirmed in the datasheet and quotation for your order.
Application fit
Industrial 2,000 V UL 1277 Type TC-ER VFD tray cable with stranded bare copper conductors, heavy-wall 90 °C RHW-2 XLPE insulation, three symmetrical uninsulated bare copper grounds, 100% helical copper tape shield, and sunlight-resistant PVC jacket.
Three uninsulated bare grounds bonded along the 100% helical copper tape deliver ultra-low EMI impedance.
Heavy-wall 2 kV 90 °C RHW-2 XLPE handles long-run PWM reflected-wave overvoltages in wet plants.
UL 1277 Direct Burial and wet-rated RHW-2 XLPE allow underground trenches and wet conduit feeders.
Sunlight-resistant black PVC jacket meets UL Type TC-ER for exposed tray drops and Class I Div 2.
Helical copper tape and Class B conductors are for fixed trays, not continuous drag-chain flexing.
Use (N)12YRDC11Y-J/O PURNot rated for motorised cable reeling; specify a rubber reeling cable for mobile equipment.
Use RG / RG-D (N)SHTOEU-JConstruction
Shown: 37-000VFD 2 kV TC-ER 3×4 AWG + 3×12 AWG — stranded bare copper RHW-2 XLPE phases and three uninsulated bare copper grounds inside an overlapping helical copper tape shield and black PVC jacket.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | Stranded bare annealed copper (ASTM B8 Class B)ASTM B3 / B8 bare copper |
| 2 | Phase insulation | 2 kV heavy-wall cross-linked polyethylene (RHW-2 XLPE)Black consecutively numbered + 3 × bare Cu grounds |
| 3 | Fillers & binder tape | Polypropylene interstitial fillers & binder tapeSymmetrical 3+3 round core assembly |
| 4 | Helical copper tape shield | 100% coverage helically applied overlapping bare copper tapeICEA S-95-658 continuous EMC shield |
| 5 | Outer jacket | Black flame- & sunlight-resistant direct-burial PVCUL 1277 Type TC-ER / FT4 |
Three black numbered 2 kV RHW-2 XLPE phases + three symmetrical bare copper grounds under helical copper tape (14 AWG–500 kcmil).
Technical data
Sizes
| Phase + 3× Ground (AWG) | Outer Ø ≈ mm | Max. R20 Ω/km | Copper index kg/km | Weight ≈ kg/km | Min. bend R 12×D mm |
|---|---|---|---|---|---|
| 3×14 AWG + 3×18 AWG | 15.6 | 8.450 | 123 | 322 | 187 |
| 3×12 AWG + 3×16 AWG | 16.6 | 5.310 | 173 | 406 | 199 |
| 3×10 AWG + 3×14 AWG | 17.9 | 3.340 | 252 | 535 | 215 |
| 3×8 AWG + 3×14 AWG | 20.7 | 2.100 | 345 | 725 | 248 |
| 3×6 AWG + 3×12 AWG | 22.8 | 1.320 | 520 | 1,004 | 274 |
| 3×4 AWG + 3×12 AWG | 26.5 | 0.832 | 747 | 1,411 | 318 |
| 3×2 AWG + 3×10 AWG | 30.9 | 0.523 | 1,153 | 2,086 | 371 |
| 3×1 AWG + 3×8 AWG | 32.9 | 0.415 | 1,486 | 2,584 | 395 |
| 3×1/0 AWG + 3×6 AWG | 35.1 | 0.329 | 1,932 | 3,236 | 421 |
| 3×2/0 AWG + 3×6 AWG | 37.6 | 0.261 | 2,320 | 3,840 | 451 |
| 3×3/0 AWG + 3×4 AWG | 41.1 | 0.207 | 3,030 | 4,904 | 493 |
| 3×4/0 AWG + 3×4 AWG | 44.3 | 0.164 | 3,649 | 5,855 | 532 |
| 3×250 kcmil + 3×4 AWG | 48.4 | 0.139 | 4,195 | 6,792 | 581 |
| 3×350 kcmil + 3×2 AWG | 54.1 | 0.099 | 5,941 | 9,343 | 649 |
| 3×500 kcmil + 3×2 AWG | 61.3 | 0.070 | 8,050 | 12,513 | 736 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC high-voltage dielectric test | Per UL 44 RHW-2 2,000 V rating | Every manufactured reel |
| Conductor DC resistance check | Per ASTM B8 Class B at 20 °C | Every reel length |
| Sample tests | ||
| TC-ER crush, impact & tape overlap | UL 1277 crush/impact & 100% tape lap | Per production lot |
| Vertical tray flame test | IEEE 1202 / UL 1685 / FT4 | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.