Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Product
658TQ / 658B & 6571TQ / 6591TQ 0.6/1 kV (BS 6883 Type SW4 / SW2) EPR-Insulated GSWB/TPBWB-Armoured & Unarmoured Offshore Rig, Switchgear & Bonding Cable Series (BS 6883, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on BS 6883 / BS 7655 GP4 / Type SW4 & SW2 — confirmed in the datasheet and quotation for your order.
Application fit
658TQ / 658B & 6571TQ / 6591TQ 0.6/1 kV (BS 6883 Type SW4 / SW2) EPR-Insulated GSWB/TPBWB-Armoured & Unarmoured Offshore Rig, Switchgear & Bonding Cable Series (BS 6883, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.
Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.
Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.
Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: 658TQ / 658B & 6571TQ / 6591TQ 0.6/1 KV (BS 6883) (BS 6883 / BS 7655 GP4 / Type SW4 & SW2) featuring class 5 flexible tinned copper (1×185 mm²), bs 7655 gp4 epr insulation and type sw4 (tq) / type sw2 (b) outer sheath (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 5 Flexible Tinned Copper (1×185 mm | BS EN 60228 Class 5 flexible tinned copper conductor (up to 630 mm²) |
| 2 | BS 7655 GP4 EPR Insulation | 90 °C ethylene-propylene rubber dielectric (0.6/1 kV to 1.8/3 kV) |
| 3 | Phosphor Bronze Non-Magnetic Braid (6571 | Non-magnetic phosphor bronze wire braid preventing eddy-current heating |
| 4 | Type SW4 (TQ) / Type SW2 (B) Outer Sheat | Heavy-duty halogen-free oil-resistant SW4 (658TQ) or PCP SW2 (658B) jacket |
Built to BS 6883 / BS 7655 GP4 / Type SW4 & SW2 with class 5 flexible tinned copper (1×185 mm²) and type sw4 (tq) / type sw2 (b) outer sheath
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to BS 6883 / BS 7655 GP4 / Type SW4 & SW2 for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 658TQ / 658B & 6571TQ / 6591TQ 0.6/1 KV (BS 6883) Construction Schedule (−40…+90 °C) | |||||||
| 658TQ 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (4G16) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 3.8 | 135 | |
| 658TQ 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (4G35) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 7.4 | 175 | |
| 658TQ 3×70+1G35 mm² | 3 × 70 + 1G35 mm² (4G70) | IEC 60228 Class 2/5 Cu/SnCu | 38.2 | 3,260 | 14.8 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (4G16) | 1.15 | 0.6/1 kV (98 A) | −40…+90 °C |
| 3 × 35 + 1G16 mm² (4G35) | 0.52 | 0.6/1 kV (158 A) | −40…+90 °C |
| 3 × 70 + 1G35 mm² (4G70) | 0.27 | 0.6/1 kV (245 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (BS 6883 / BS 7655 GP4 / Type SW4 & SW2) | DC resistance at 20 °C / optical attenuation and outer diameter within BS 6883 / BS 7655 GP4 / Type SW4 & SW2 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (BS 6883 / BS 7655 GP4 / Type SW4 & SW2) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (BS 6883 / BS 7655 GP4 / Type SW4 & SW2) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking