Contact

AC Ventilated Air-Cooled High-Current Welding CableBlue ventilated-jacket extra-flexible air-cooled high-current welding lead

AC Ventilated Weld Cable houses extra-flexible bare copper ropes inside a loose-fit ventilated blue elastomeric sheath that promotes natural convection heat dissipation during high-duty-cycle welding and testing.

Oil-resistant
Flame-retardant
Approved
Order designation
AC Ventilated Weld Cable 1×300 mm²
Outer Ø
31.0 mm
Max. R20
0.064 Ω/km
Weight
4,426 kg/km
Min. bend R
186 mm
All sizes (8)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Test voltage 2.5 kV AC
Temp. (fixed)
-25°C…+85°C
Flexing: -20 °C to +85 °C
Construction
Cu-ETP
Ventilated separator channel around
Min. bend radius
6 × OD
High-current flexible routing
Conductor
Bare Cu · Cl.6
Per EN 50525-2-81 (ref.)
Size range
1×120–1×630
8 standard configurations

Typical values for this cable type, based on EN 50525-2-81 (ref.) · IEC 60228 Class 6 · ISO 5828 (ref.) — confirmed in the datasheet and quotation for your order.

Application fit

Is AC Ventilated Weld Cable right for your machine?

AC Ventilated Weld Cable houses extra-flexible bare copper ropes inside a loose-fit ventilated blue elastomeric sheath that promotes natural convection heat dissipation during high-duty-cycle welding and testing.

Fixed installation

Suitable

Durable 600 V Cu-ETP geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.

Motor stator, traction & converter leads

Suitable

Extra-flexible 600 V Cu-ETP stranding and 6×D bend radius connect dynamic welding guns, drives, and furnace feeders.

Welding power source & electrode lead

Suitable

Extra-flexible heat- and spatter-resistant 600 V Cu-ETP build delivers low-drop current to welding tongs and shop floor leads.

Mobile generator & site power hookup

Suitable

Flexible oil- and weather-resistant 600 V Cu-ETP design handles temporary site power drops, mobile generators, and distribution boxes.

Energy chain / drag chain

Not suitable

600 V Cu-ETP construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

600 V Cu-ETP outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesPower transformers, switchgear & busduct jointsResistance welding guns & heavy fabrication shopsBESS battery racks, EV test benches & rectifiersSteel mills, foundries & high-current power bays

Construction

Layer by layer

Representative construction of AC Ventilated Weld Cable: IEC 60228 Class 6 extra-flexible bare annealed copper, Ventilated separator channel around extra-flexible bare copper rope, and Blue abrasion-, oil- & heat-resistant ventilated elastomeric rubber outer sheath.

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorIEC 60228 Class 6 extra-flexible bare annealed copperIEC 60228 Class 6
2Cooling core / primary dielectricVentilated separator channel around extra-flexible bare copper ropeEN 50525-2-81 (ref.)
3Outer sheath / hoseBlue abrasion-, oil- & heat-resistant ventilated elastomeric rubber outer sheathConvection Air Cooling

AC Ventilated Weld Cable High-Duty

Single-core high-duty construction protected by Blue abrasion-, oil- & heat-resistant ventilated elastomeric rubber outer sheath.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on EN 50525-2-81 (ref.) · IEC 60228 Class 6 · ISO 5828 (ref.). Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
600 V
Test voltage
2.5 kV AC
Conductor
Bare Cu · Cl.6
Core / dielectric
Ventilated separator channel around
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-25 °C to +85 °C
Temp. range (flexing)
-20 °C to +85 °C
Peak / short-circuit
+160 °C (5 s)
Min. bending radius
6 × OD

Resistance

Primary performance
Convection Air Cooling
Environment / duty
High-Visibility Blue Sheath
Mechanical / special
Extra-Flex Bare Copper
Outer finish
Blue abrasion-, oil- & heat-resistant

Sizes

Air-Cooled High-Current Sizes (mm²)
Cross-section
mm²
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
6×D mm
1×120 mm²22.10.1611,1521,838133
1×150 mm²23.90.1291,4402,272143
1×185 mm²25.80.1061,7762,777155
1×240 mm²28.50.0802,3043,569171
1×300 mm²31.00.0642,8804,426186
1×400 mm²34.80.0493,8405,856209
1×500 mm²38.10.0384,8007,280229
1×630 mm²41.90.0296,0489,125251
  • Conductor DC resistance R20 at 20 °C per IEC 60228 Class 6.
  • Minimum bending radius calculated at 6 × nominal outer diameter (OD). Custom terminations available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric withstand test2.5 kV AC without breakdownEvery manufactured length
Continuity & conductor DC resistancePer IEC 60228 Class 6 at 20 °CEvery drum / assembly
Sample tests
Tensile, dimensional & pressure checkRated -25 °C to +85 °C continuousPer production lot
Environmental, thermal & mechanical qualificationConvection Air Cooling · High-Visibility Blue SheathType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

EN 50525-2-81 (ref.)IEC 60228 Class 6ISO 5828 (ref.)EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

AC Ventilated Weld Cable 600 V TEBAOFLEX.COM [EN 50525-2-81 (ref.)] [Size] [Metre mark]
Delivery form
Custom assemblies, coils or export drums
Standard lengths
Cut-to-length · 100 m · 500 m · 1,000 m
MOQ
1 assembly / 50 m (stock) · 300 m (custom)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-23
Updated
2026-11-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes AC Ventilated Weld Cable suited for demanding 600 V installations?
AC Ventilated Weld Cable combines IEC 60228 Class 6 extra-flexible bare annealed copper with Ventilated separator channel around extra-flexible bare copper rope and Blue abrasion-, oil- & heat-resistant ventilated elastomeric rubber outer sheath. Air-breathing sheath geometry lowers conductor temperature rise versus tight-extruded welding leads.
What minimum bending radius should be respected for AC Ventilated Weld Cable?
Maintain a minimum bending radius of 6 × OD across -20 °C to +85 °C flexing temperatures to ensure long mechanical and dielectric service life.
Can AC Ventilated Weld Cable be delivered pre-terminated with custom lugs, water fittings, or subsea connectors?
Yes. TEBAOFLEX supplies AC Ventilated Weld Cable either in bulk lengths or factory-assembled with copper lugs, water-cooled swivel fittings, or molded subsea wet-mate connectors.
What quality tests and certificates accompany every shipment of AC Ventilated Weld Cable?
AC Ventilated Weld Cable conforms to EN 50525-2-81 (ref.), IEC 60228 Class 6, ISO 5828 (ref.) (Convection Air Cooling) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for AC Ventilated Weld Cable

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

AC Ventilated Air-Cooled High-Current Welding Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote