Fixed installation
Two counter-wound galvanized steel wire armour layers resist roof-fall rock impact and eliminate tensile twist in vertical shafts.
Product
MGM 109 Type 1023 / 1024 Double-Armoured LV Feeder Cable is the British Coal Specification MGM 109 and BS 6708 640/1100 V underground coal and hard-rock roadway power cable in 3-core (Type 1023) and 4-core (Type 1024) constructions (16 mm² to 185 mm²)
Typical values for this cable type, based on MGM 109 / BS 6708 (Type 1023 3-Core & Type 1024 4-Core 640/1100 V DWA) — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground coal mine gate roads, incline shafts, haulage drifts, and gate-end box distribution where roof-fall crush loads and vertical suspension require Double Wire Armour (DWA).
Two counter-wound galvanized steel wire armour layers resist roof-fall rock impact and eliminate tensile twist in vertical shafts.
Terminates directly into flameproof BS 6708 / NCB half-couplers, bolted couplers, and gate-end switchgear.
Bitumen/wax corrosion compound over the DWA layers plus heavy PVC sheath protects against acidic mine water.
Heavy fixed roadway and shaft feeder cable.
MGM 109 Type 1012 / 1013 / 1014Construction
Class 2 stranded plain or tinned copper conductors (3-core Type 1023 or 4-core Type 1024, 16 to 185 mm²), 90 °C Type GP4 EPR insulation
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 2 stranded copper conductors | BS EN 60228 Class 2 circular stranded annealed copper (16 mm² to 185 mm², 3-core orMGM 109 / BS 6708 |
| 2 | Type GP4 EPR rubber insulation (90 °C) | Cross-linked ethylene-propylene elastomer Type GP4 per BS 7655-1.2BS 6708 |
| 3 | Extruded PVC inner bedding | Flame-retardant PVC bedding filling core intersticesMGM 109 |
| 4 | Double wire armour (DWA — 2 counter | Two counter-helical layers of galvanized steel wires (+ tinned Cu wires to meet ≥ 75 %MGM 109 Digit 3 = '2' |
| 5 | Heavy-duty mining FR-PVC outer sheath | Abrasion-, oil-, and mine-flame-retardant PVC outer sheath (RAL 9005 Black)MGM 109 / BS 6708 |
3-core (Brown, Black, Grey) 640/1100 V double-wire-armoured roadway power feeder (16 to 185 mm²).
4-core (3 phases + pilot/neutral, 2.5 to 120 mm²) 640/1100 V double-wire-armoured mining feeder.
Technical data
Sizes
Nominal dimensions, copper weights, DC resistance and current ratings for MGM 109 Type 1023 / 1024 per MGM 109 / BS 6708 (Type 1023 3-Core & Type 1024 4-Core
| Order designation | Cores × Size | Main cross-section | Outer Ø ≈ mm | Copper kg/km | Weight ≈ kg/km | Min. bend R fixed mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Standard MGM 109 Type 1023 / 1024 configurations | |||||||
| MGM 109 Type 1024 4C × 16 mm² 640/1100V DWA | 4 × 16 mm² (Type 1024) | 16.0 mm² | 31.2 | 680 | 2,480 | 374 | |
| MGM 109 Type 1023 3C × 25 mm² 640/1100V DWA | 3 × 25 mm² (Type 1023) | 25.0 mm² | 32.8 | 820 | 2,760 | 394 | |
| MGM 109 Type 1023 3C × 50 mm² 640/1100V DWA | 3 × 50 mm² (Type 1023) | 50.0 mm² | 38.6 | 1,610 | 3,940 | 463 | |
| MGM 109 Type 1023 3C × 95 mm² 640/1100V DWA | 3 × 95 mm² (Type 1023) | 95.0 mm² | 47.4 | 3,080 | 6,120 | 569 | |
| MGM 109 Type 1023 3C × 120 mm² 640/1100V DWA | 3 × 120 mm² (Type 1023) | 120.0 mm² | 51.2 | 3,890 | 7,280 | 614 | |
| MGM 109 Type 1023 3C × 185 mm² 640/1100V DWA | 3 × 185 mm² (Type 1023) | 185.0 mm² | 59.8 | 5,980 | 10,250 | 718 | |
| Configuration | Max. DC R @ 20 °C Ω/km | Iz free air A | Iz tray / duct A | Isc (1 s) kA | Voltage drop mV/A/m | Dielectric test V |
|---|---|---|---|---|---|---|
| 4 × 16 mm² (Type 1024) | 1.15 | 96 | 86 | 2.29 | 2.50 | 3,500 |
| 3 × 25 mm² (Type 1023) | 0.73 | 127 | 114 | 3.58 | 1.60 | 3,500 |
| 3 × 50 mm² (Type 1023) | 0.39 | 190 | 171 | 7.15 | 0.85 | 3,500 |
| 3 × 95 mm² (Type 1023) | 0.19 | 285 | 256 | 13.59 | 0.44 | 3,500 |
| 3 × 120 mm² (Type 1023) | 0.15 | 330 | 297 | 17.16 | 0.36 | 3,500 |
| 3 × 185 mm² (Type 1023) | 0.10 | 425 | 382 | 26.46 | 0.25 | 3,500 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| 3.5 kV AC dielectric & insulation resistance | 3,500 V AC for 5 min per MGM 109 / BS 6708 | 100 % of drums |
| Phase & DWA armour DC resistance ratio | Armour conductance ≥ 75 % of largest phase conductor | 100 % of drums |
| Sample tests | ||
| GP4 EPR hot-set & galvanizing coat weight | BS 7655-1.2 EPR & BS EN 10257-1 armour wire checks | Per production batch |
| Underground mining flame & impact crush test | Pass MGM 109 / BS 6708 mechanical & flame approval | Type approval |
Marking & supply
Sheath marking