ARG7H1OR 12/20 (24) kV medium-voltage three-core distribution cable featuring compact Class 2 aluminium conductors, triple-extruded G7 HEPR dielectric, per-phase H1 copper tape screens and a flame-retardant red Rz PVC outer sheath.
Typical values for this cable type, based on CEI UNEL 35755 / IEC 60502-2 — confirmed in the datasheet and quotation for your order.
Application fit
ARG7H1OR 12/20 (24) kV medium-voltage three-core distribution cable featuring compact Class 2 aluminium conductors, triple-extruded G7 HEPR dielectric, per-phase H1 copper tape screens and a flame-retardant red Rz PVC outer sheath.
Engineered for fixed medium-voltage distribution in cable trenches, ducts, trays and indoor substations.
Suitable for primary 12/20 kV industrial plant feeders and transformer interconnections.
Suitable for fixed tunnel brackets where PVC flame-retardant category per IEC 60332-1-2 is permitted.
Class 2 compact aluminium conductors are for static installation only; not for reeling drums.
CHKCYDYConstruction
Shown: ARG7H1OR (CEI UNEL 35755 / IEC 60502-2) featuring aluminium conductors (3x50 mm²), triple-extruded core stack and common outer sheath (or) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Aluminium Conductors (3x50 mm²) | Class 2 compact circular stranded aluminium alloy conductors (Code A) for medium-voltage distribution networksCEI UNEL 35755 / IEC 60502-2 |
| 2 | Triple-Extruded Core Stack | Simultaneously extruded inner semiconductive screen, high-modulus G7 HEPR insulation (105 °C rated), and strippable outer semiconCEI UNEL 35755 / IEC 60502-2 |
| 3 | Individual Phase Screen (H1) | Helically lapped plain annealed copper tape applied over each phase core for earth-fault current returnCEI UNEL 35755 / IEC 60502-2 |
| 4 | Interstitial Filler Bedding | Extruded non-hygroscopic polymeric filler compound stabilizing the three-core layCEI UNEL 35755 / IEC 60502-2 |
| 5 | Common Outer Sheath (OR) | Abrasion- and flame-retardant red Rz polyvinyl chloride (PVC) overall outer jacketCEI UNEL 35755 / IEC 60502-2 |
Built to CEI UNEL 35755 / IEC 60502-2 with aluminium conductors (3x50 mm²) and common outer sheath (or)
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to CEI UNEL 35755 / IEC 60502-2 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| ARG7H1OR Construction Schedule (−25…+90 °C) | |||||||
| ARG7H1OR 3×35 mm² 12/20 kV | 3 × 35 mm² Al | Class 2 compact Al + H1 screen | 46.0 | 1,820 | 10.5 | 645 | |
| ARG7H1OR 3×50 mm² 12/20 kV | 3 × 50 mm² Al | Class 2 compact Al + H1 screen | 49.0 | 2,090 | 15.0 | 690 | |
| ARG7H1OR 3×70 mm² 12/20 kV | 3 × 70 mm² Al | Class 2 compact Al + H1 screen | 53.0 | 2,480 | 21.0 | 745 | |
| ARG7H1OR 3×95 mm² 12/20 kV | 3 × 95 mm² Al | Class 2 compact Al + H1 screen | 56.5 | 2,910 | 28.5 | 790 | |
| ARG7H1OR 3×120 mm² 12/20 kV | 3 × 120 mm² Al | Class 2 compact Al + H1 screen | 60.0 | 3,340 | 36.0 | 840 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 3 × 35 mm² Al | 0.87 | 12/20 kV / 135 A | −25…+90 °C |
| 3 × 50 mm² Al | 0.64 | 12/20 kV / 162 A | −25…+90 °C |
| 3 × 70 mm² Al | 0.44 | 12/20 kV / 200 A | −25…+90 °C |
| 3 × 95 mm² Al | 0.32 | 12/20 kV / 242 A | −25…+90 °C |
| 3 × 120 mm² Al | 0.25 | 12/20 kV / 278 A | −25…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (CEI UNEL 35755 / IEC 60502-2) | Electrical parameters and outer diameter within CEI UNEL 35755 / IEC 60502-2 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (CEI UNEL 35755 / IEC 60502-2) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (CEI UNEL 35755 / IEC 60502-2) | Verified structural and dielectric integrity across −25…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.