Immersion & wet locations
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Product
MIL-DTL-24643/56 & /57 Types LS2SWL-7, LS2UW-42 & LS2UWS-42 Watertight Shielded Multi-Pair Shipboard & Submarine Communication/Control Cable (MIL-DTL-24643/56 & /57, 600 V, -30 °C to +105 °C, min. bend radius 8 × OD).
Typical values for this cable type, based on MIL-DTL-24643/56F & /57F EMP-Shielded Submarine Standard — confirmed in the datasheet and quotation for your order.
Application fit
MIL-DTL-24643/56 & /57 Types LS2SWL-7, LS2UW-42 & LS2UWS-42 Watertight Shielded Multi-Pair Shipboard & Submarine Communication/Control Cable (MIL-DTL-24643/56 & /57, 600 V, -30 °C to +105 °C, min. bend radius 8 × OD).
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.
Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.
Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.
Outboard marine and feeder construction is not designed for high-speed crane festoon trolleys.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: MIL-DTL-24643/56 & /57 (LS2SWL-7 / LS2UWS-42) (MIL-DTL-24643/56F & /57F EMP-Shielded Submarine Standard) featuring watertight pairs (7×2×16 awg / 42×2×26 awg), individual pair braid & tapes (ls2swl-7) and cross-linked polyolefin jacket (xlpo) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Watertight Pairs (7×2×16 AWG / 42×2×26 AWG) | Longitudinally water-blocked tinned copper conductors with XLPE insulation |
| 2 | Individual Pair Braid & Tapes (LS2SWL-7) | Tin-coated copper braid shield + two sealed polyester tapes over each 16 AWG pair |
| 3 | Watertight Core & Separator Tape | Water-Blocking / watertight fillers preventing inter-compartment flooding |
| 4 | Double Overall Tin-Coated Copper Braid | Dual overall copper braid shields meeting MIL-DTL-24643 EMP & Zt limits |
| 5 | Cross-Linked Polyolefin Jacket (XLPO) | 1.65–1.91 mm black low-smoke zero-halogen XLPO outer sheath (optional Al armor) |
Built to MIL-DTL-24643/56F & /57F EMP-Shielded Submarine Standard with watertight pairs (7×2×16 awg / 42×2×26 awg) and cross-linked polyolefin jacket (xlpo)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to MIL-DTL-24643/56F & /57F EMP-Shielded Submarine Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| MIL-DTL-24643/56 & /57 (LS2SWL-7 / LS2UWS-42) Construction Schedule (−30…+105 °C) | |||||||
| MIL-DTL-24643 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| MIL-DTL-24643 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| MIL-DTL-24643 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 600 V (45–100 Ω data) | −30…+105 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 600 V (45–100 Ω data) | −30…+105 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 600 V (High-Power Hybrid) | −30…+105 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (MIL-DTL-24643/56F & /57F EMP-Shielded Submarine Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within MIL-DTL-24643/56F & /57F EMP-Shielded Submarine Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (MIL-DTL-24643/56F & /57F EMP-Shielded Submarine Standard) | Zero dielectric breakdown and verified insulation resistance for 600 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (MIL-DTL-24643/56F & /57F EMP-Shielded Submarine Standard) | Verified submersion integrity, tensile load and thermal stability across −30…+105 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.