Contact

ROZ1-K (EMC) 0.6/1kV IEC 60502-1ROZ1-K (EMC) 0.6/1kV IEC 60502-1 manufactured to IEC 60502-1 / IEC 60332-3-24, rated 0.6/1 kV (Test 3.5 kV) and -25°C to +90°C with a 12 × OD minimum bending radius for infrastructure & construction installations.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Flame-retardant
EMC screen
Oil-resistant
Approved
Order designation
ROZ1-K (EMC) 0.6/1kV IEC 60502-1 (4G6 mm²)
Outer diameter
15.2 mm
Cable weight
543 kg/km
Min. bend radius
182 mm
Conductor & shield
Class 5 Flexible Plain Copper
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
IEC 60502-1 / IEC 60332-3-24
Temperature
-25°C to +90°C
Fixed / flex duty
Min. bend radius
12 × OD
15.2–21.0 mm
Screening
Foil + TC Braid
360° foil + tinned Cu braid
Outer sheath
LSZH Jacket
Halogen-free fire-safety corridors
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per IEC 60502-1 / IEC 60332-3-24 (ROZ1-K (EMC) 0.6/1kV IEC 60502-1) — confirmed in the datasheet and quotation for your order.

Application fit

Is ROZ1-K (EMC) 0.6/1kV IEC 60502-1 right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.

Motor stator, traction & converter leads

Suitable

Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

TBM gantry & advancing tunnel reel

Suitable

Low-smoke zero-halogen outer sheath minimizes toxic acid gas emission and smoke obscuration in fire events.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Dual-tier power & PLC tray

Suitable

Screened 0.6/1 kV XLPE/LSZH construction suppresses electromagnetic interference on shared industrial power and PLC signal trays.

Typical machinesBuilding & Fire SafetyPower distribution & utility networksRailways, tunnels & public infrastructureProcess instrumentation & oil/gas skidsIndustrial automation & control cabinetsRenewable energy, marine & heavy industry

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

ROZ1-K (EMC) 0.6/1kV IEC 60502-1 – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
1Conductor4G6.0 mm² Class 5 Flexible Bare Cu
2Insulation & Core Identification90°C XLPE insulation (6.0 mm² Class 5 Flexible Bare Copper)
3Screen / Bedding / Armour LayerPES separator tape + 100% Al/PES foil tape screen + Tinned Copper Wire Braid (TCWB) EMC screen
4Outer Protective SheathBlack Compound ST8 Low Smoke Zero Halogen (LSZH) outer sheath (OD 15.20 mm)

4G6 mm²

Class 5 Flexible Plain Copper · Outer diameter 15.2 mm

4G10 mm²

Class 5 Flexible Plain Copper · Outer diameter 17.9 mm

4G16 mm²

Class 5 Flexible Plain Copper · Outer diameter 21.0 mm

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per IEC 60502-1 / IEC 60332-3-24 (ROZ1-K (EMC) 0.6/1kV IEC 60502-1). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
0.6/1 kV (Test 3.5 kV)
Conductor & core insulation
4G6.0 mm² Class 5 Flexible Bare Cu · 90°C XLPE insulation (6.0 mm² Class 5 Flexible Bare Copper)
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
-25°C to +90°C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
IEC 60502-1 / IEC 60332-3-24

Mechanical

Minimum bending radius
12 × OD
Screening / armour architecture
PES separator tape + 100% Al/PES foil tape screen + Tinned Copper Wire Braid (TCWB) EMC screen
Outer sheath material & colour
Black Compound ST8 Low Smoke Zero Halogen (LSZH) outer sheath (OD 15.20 mm)

Reference standards

Reference standard
IEC 60502-1 / IEC 60332-3-24
Hazardous Substance Compliance
CE, UKCA, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
ROZ1-K (EMC) 0.6/1kV IEC 60502-1
4G6 mm²Class 5 Flexible Plain Copper90°C XLPE insulationLSZH Jacket15.21823.02282.454343 AROZ1-K (EMC) 0.6/1kV IEC 60502-1 (4G6 mm²)
4G10 mm²Class 5 Flexible Plain Copper90°C XLPE insulationLSZH Jacket17.92151.81393.175660 AROZ1-K (EMC) 0.6/1kV IEC 60502-1 (4G10 mm²)
4G16 mm²Class 5 Flexible Plain Copper90°C XLPE insulationLSZH Jacket21.02521.13537.71,03480 AROZ1-K (EMC) 0.6/1kV IEC 60502-1 (4G16 mm²)
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228Every manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation, screen or armourEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing and compliant with reference standard limitsType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60502-1 / IEC 60332-3-24 CompliantEN 10204 3.1 Factory Test CertificateCE, UKCA, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

ROZ1-K (EMC) 0.6/1KV IEC 60502-1 / TEBAOFLEX.COM — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
250 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-04
Updated
2026-11-04

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is ROZ1-K (EMC) 0.6/1kV IEC 60502-1 designed for?
ROZ1-K (EMC) 0.6/1kV IEC 60502-1 is engineered for infrastructure & construction installations under IEC 60502-1 / IEC 60332-3-24, operating over -25°C to +90°C with a minimum bending radius of 12 × OD.
How is ROZ1-K (EMC) 0.6/1kV IEC 60502-1 constructed across its layers?
Its 4-layer architecture combines 4G6.0 mm² Class 5 Flexible Bare Cu with 90°C XLPE insulation (6.0 mm² Class 5 Flexible Bare Copper), PES separator tape + 100% Al/PES foil tape screen + Tinned Copper Wire Braid (TCWB) EMC screen and Black Compound ST8 Low Smoke Zero Halogen (LSZH) outer sheath (OD 15.20 mm).
What standards and routine factory tests apply to ROZ1-K (EMC) 0.6/1kV IEC 60502-1?
Every manufactured drum is tested to IEC 60502-1 / IEC 60332-3-24 for conductor continuity, dielectric voltage withstand and sheath integrity, supplied with an EN 10204 3.1 inspection certificate.
What sizes and drum lengths are available for ROZ1-K (EMC) 0.6/1kV IEC 60502-1?
Representative sizes include 4G6 mm², 4G10 mm² and 4G16 mm², supplied on 250 m, 500 m or 1,000 m export drums or custom cut lengths.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for ROZ1-K (EMC) 0.6/1kV IEC 60502-1

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

ROZ1-K (EMC) 0.6/1kV IEC 60502-1

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote