Fixed installation
Durable 1000 V EPDM geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.
Product
AC Isolated-Rope Jumper groups multiple separated bare copper rope bundles inside a rugged black EPDM rubber sheath to reduce AC skin/proximity effects and simplify multi-lug termination on heavy transformers.
Typical values for this cable type, based on IEC 60228 Class 6 · DIN VDE 0282 (ref.) · EN 50363-2-1 — confirmed in the datasheet and quotation for your order.
Application fit
AC Isolated-Rope Jumper groups multiple separated bare copper rope bundles inside a rugged black EPDM rubber sheath to reduce AC skin/proximity effects and simplify multi-lug termination on heavy transformers.
Durable 1000 V EPDM geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.
Extra-flexible 1000 V EPDM stranding and 8×D bend radius connect dynamic welding guns, drives, and furnace feeders.
Rugged 1000 V EPDM construction handles stationary heavy-plant cable trenches, rolling-mill feeders, and industrial power bays.
High-capacity 1000 V EPDM feeder connects motor control centers (MCC) cleanly to heavy plant machinery and main distribution panels.
1000 V EPDM construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR1000 V EPDM outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of AC Isolated-Rope Jumper: IEC 60228 Class 6 extra-flexible bare annealed copper, Individually wrapped/separated Class 6 bare copper sub-ropes, and Black ozone-, oil- & abrasion-resistant EPDM rubber outer sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | IEC 60228 Class 6 extra-flexible bare annealed copperIEC 60228 Class 6 |
| 2 | Cooling core / primary dielectric | Individually wrapped/separated Class 6 bare copper sub-ropesIEC 60228 Class 6 |
| 3 | Outer sheath / hose | Black ozone-, oil- & abrasion-resistant EPDM rubber outer sheathReduced AC Proximity Loss |
Single-core high-duty construction protected by Black ozone-, oil- & abrasion-resistant EPDM rubber outer sheath.
Technical data
Sizes
| Cross-section mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Copper index kg/km | Weight ≈ kg/km | Min. bend R 8×D mm |
|---|---|---|---|---|---|
| 1×120 mm² | 22.1 | 0.161 | 1,152 | 1,838 | 177 |
| 1×150 mm² | 23.9 | 0.129 | 1,440 | 2,272 | 191 |
| 1×185 mm² | 25.8 | 0.106 | 1,776 | 2,777 | 206 |
| 1×240 mm² | 28.5 | 0.080 | 2,304 | 3,569 | 228 |
| 1×300 mm² | 31.0 | 0.064 | 2,880 | 4,426 | 248 |
| 1×400 mm² | 34.8 | 0.049 | 3,840 | 5,856 | 278 |
| 1×500 mm² | 38.1 | 0.038 | 4,800 | 7,280 | 305 |
| 1×630 mm² | 41.9 | 0.029 | 6,048 | 9,125 | 335 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric withstand test | 3.5 kV AC without breakdown | Every manufactured length |
| Continuity & conductor DC resistance | Per IEC 60228 Class 6 at 20 °C | Every drum / assembly |
| Sample tests | ||
| Tensile, dimensional & pressure check | Rated -30 °C to +90 °C continuous | Per production lot |
| Environmental, thermal & mechanical qualification | Reduced AC Proximity Loss · Multi-Rope Flex Geometry | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.