Fixed installation
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Product
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Typical values for this cable type, based on Reference specification per CEI 20-13 / HD 620 (ARE4H5E / ARE4H5EX / ARE4H51R 12/20kV Italian MV) — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.
Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.
Outer sheath compound resists industrial oils, moisture ingress, abrasion and outdoor weathering.
Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.
Use WXG / WXG-D MV Reeling CableHigh-dielectric 12/20 kV XLPE/PE construction feeds medium- and high-voltage substation duct banks, transformer bays, and utility feeders.
Construction
Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | 1×150 mm² Class 2 Compacted Al |
| 2 | Insulation & Core Identification | CEI 20-13 DIX 8 XLPE dielectric (150 mm² Compacted Aluminium) |
| 3 | Screen / Bedding / Armour Layer | Semi-conductive longitudinal water-blocking swellable tape + Longitudinally bonded 0.2 mm aluminium foil metallic screen |
| 4 | Outer Protective Sheath | Black DMP 2 Polyethylene (PE) outer sheath with red identification stripes (OD 31.2 mm) |
Class 2 Compacted Stranded Aluminium · Outer diameter 31.2 mm
Class 2 Compacted Stranded Aluminium · Outer diameter 36.8 mm
Class 2 Compacted Stranded Aluminium · Outer diameter 43.1 mm
Technical data
Sizes
Representative configurations from the series specification; select a row to prefill the quotation tool.
| Configuration | Conductor & shield | Insulation / wall | Outer sheath | Outer diameter mm | Min. bend radius mm | Max. conductor resistance @ 20 °C Ω/km | Conductor weight kg/km | Cable weight kg/km | Key electrical / optical rating | Part designation | Enquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ARE4H5E / ARE4H5EX / ARE4H51R 12/20kV Italian MV | |||||||||||
| 1×150 mm² | Class 2 Compacted Stranded Aluminium | CEI 20-13 DIX 8 XLPE dielectric | Outdoor PE | 31.2 | 468 | 0.19 | 610.3 | 1,606 | 250 A | ARE4H5E / ARE4H5EX / ARE4H51R 12/20kV Italian MV (1×150 mm²) | |
| 1×185 mm² | Class 2 Compacted Stranded Aluminium | CEI 20-13 DIX 8 XLPE dielectric | Outdoor PE | 36.8 | 552 | 0.15 | 849.7 | 2,236 | 286 A | ARE4H5E / ARE4H5EX / ARE4H51R 12/20kV Italian MV (1×185 mm²) | |
| 1×240 mm² | Class 2 Compacted Stranded Aluminium | CEI 20-13 DIX 8 XLPE dielectric | Outdoor PE | 43.1 | 646 | 0.12 | 1,162.4 | 3,059 | 336 A | ARE4H5E / ARE4H5EX / ARE4H51R 12/20kV Italian MV (1×240 mm²) | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & continuity | Within maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228 | Every manufactured drum length |
| Dielectric withstand / spark test | No breakdown across insulation, screen or armour | Every manufactured drum length |
| Sample tests | ||
| Vertical flame propagation & jacket qualification | Self-extinguishing and compliant with reference standard limits | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.