Contact

EAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV CableEAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV Cable manufactured to NBN C 32-131 / HD 603, rated 0.6/1 kV and -25°C to +90°C with a 12 × OD minimum bending radius for infrastructure & construction installations.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Flame-retardant
Oil-resistant
Approved
Order designation
EAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV (4×25 mm²)
Outer diameter
22.8 mm
Cable weight
858 kg/km
Min. bend radius
274 mm
Conductor & shield
Class 1/2 Aluminium
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
NBN C 32-131 / HD 603
Temperature
-25°C to +90°C
Fixed / flex duty
Min. bend radius
12 × OD
22.8–31.5 mm
Screening
Unshielded
Fixed / flex duty
Outer sheath
Industrial PVC
Oil & sunlight resistant
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per NBN C 32-131 / HD 603 (EAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV) — confirmed in the datasheet and quotation for your order.

Application fit

Is EAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.

Motor stator, traction & converter leads

Suitable

Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

Offshore platform & shipboard deck trays

Suitable

Outer sheath compound resists industrial oils, moisture ingress, abrasion and outdoor weathering.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Dual-tier power & PLC tray

Suitable

Screened 0.6/1 kV XLPE/PVC construction suppresses electromagnetic interference on shared industrial power and PLC signal trays.

Typical machinesBuilding & Fire SafetyPower distribution & utility networksRailways, tunnels & public infrastructureProcess instrumentation & oil/gas skidsIndustrial automation & control cabinetsRenewable energy, marine & heavy industry

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

EAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
1Conductor4×25 mm² Class 1 Solid / Class 2 Stranded Al
2Insulation & Core IdentificationNBN C 32-131 XLPE core insulation (25 mm² Aluminium)
3Screen / Bedding / Armour LayerExtruded PVC inner filler compound
4Outer Protective SheathBlack heavy-duty reinforced PVC outer sheath (OD 22.8 mm)

4×25 mm²

Class 1/2 Aluminium · Outer diameter 22.8 mm

4×35 mm²

Class 1/2 Aluminium · Outer diameter 26.9 mm

4×50 mm²

Class 1/2 Aluminium · Outer diameter 31.5 mm

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per NBN C 32-131 / HD 603 (EAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
0.6/1 kV
Conductor & core insulation
4×25 mm² Class 1 Solid / Class 2 Stranded Al · NBN C 32-131 XLPE core insulation (25 mm² Aluminium)
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
-25°C to +90°C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
NBN C 32-131 / HD 603

Mechanical

Minimum bending radius
12 × OD
Screening / armour architecture
Extruded PVC inner filler compound
Outer sheath material & colour
Black heavy-duty reinforced PVC outer sheath (OD 22.8 mm)

Reference standards

Reference standard
NBN C 32-131 / HD 603
Hazardous Substance Compliance
CE, UKCA, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Conductor weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
EAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV
4×25 mm²Class 1/2 AluminiumNBN C 32-131 XLPE core insulationIndustrial PVC22.82741.13326.085881 AEAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV (4×25 mm²)
4×35 mm²Class 1/2 AluminiumNBN C 32-131 XLPE core insulationIndustrial PVC26.93230.81453.71,194101 AEAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV (4×35 mm²)
4×50 mm²Class 1/2 AluminiumNBN C 32-131 XLPE core insulationIndustrial PVC31.53780.56620.51,633122 AEAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV (4×50 mm²)
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228Every manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation, screen or armourEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing and compliant with reference standard limitsType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

NBN C 32-131 / HD 603 CompliantEN 10204 3.1 Factory Test CertificateCE, UKCA, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

EAXVB 0.6/1KV NBN C 32-131 BELGIAN ALUMINIUM LV CABLE / TEBAOFLEX.COM — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
250 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-04
Updated
2026-11-04

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is EAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV designed for?
EAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV is engineered for infrastructure & construction installations under NBN C 32-131 / HD 603, operating over -25°C to +90°C with a minimum bending radius of 12 × OD.
How is EAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV constructed across its layers?
Its 4-layer architecture combines 4×25 mm² Class 1 Solid / Class 2 Stranded Al with NBN C 32-131 XLPE core insulation (25 mm² Aluminium), Extruded PVC inner filler compound and Black heavy-duty reinforced PVC outer sheath (OD 22.8 mm).
What standards and routine factory tests apply to EAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV?
Every manufactured drum is tested to NBN C 32-131 / HD 603 for conductor continuity, dielectric voltage withstand and sheath integrity, supplied with an EN 10204 3.1 inspection certificate.
What sizes and drum lengths are available for EAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV?
Representative sizes include 4×25 mm², 4×35 mm² and 4×50 mm², supplied on 250 m, 500 m or 1,000 m export drums or custom cut lengths.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for EAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

EAXVB 0.6/1kV NBN C 32-131 Belgian Aluminium LV Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote