VFD inverter to AC motor screened feeder
Low-capacitance 600/1000 V XLPE/TPE construction and EMC screen suppress PWM switching noise between inverter and AC motor.
Product
SPEC 45441 600/1000 V VFD Pair combines three XLPE phases, ground, and an individually foil-shielded 16 AWG brake/temperature-sensor pair under overall dual EMC screening and a black oil-resistant jacket.
Typical values for this cable type, based on UL 1277 Type TC-ER · UL 2277 Type WTTC · CSA AWM I/II A/B FT4 — confirmed in the datasheet and quotation for your order.
Application fit
SPEC 45441 600/1000 V VFD Pair combines three XLPE phases, ground, and an individually foil-shielded 16 AWG brake/temperature-sensor pair under overall dual EMC screening and a black oil-resistant jacket.
Low-capacitance 600/1000 V XLPE/TPE construction and EMC screen suppress PWM switching noise between inverter and AC motor.
Balanced 600/1000 V XLPE/TPE geometry cuts common-mode bearing currents and terminates cleanly inside motor junction boxes.
Durable 600/1000 V XLPE/TPE construction powers industrial process pumps, boosters, and compressor skids under continuous plant duty.
Screened 600/1000 V XLPE/TPE construction suppresses electromagnetic interference on shared industrial power and PLC signal trays.
600/1000 V XLPE/TPE construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR600/1000 V XLPE/TPE build lacks anti-torsion tensile reinforcement for motorised drum reeling; select a dedicated reeling cable.
Use RG / RG-D (N)SHTOEU-JConstruction
Representative construction of SPEC 45441 600/1000V VFD Pair: tinned copper conductors, UL 44 XHHW-2 thermoset XLPE (90 °C), Individually shielded brake/PTC pair + overall foil & ≥ 85% tinned Cu braid, and Black oil- & UV-resistant flame-retardant PVC/TPE jacket.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | ASTM B172 Class K flexible tinned annealed copperASTM B172 Class K / UL 1277 |
| 2 | Core insulation | UL 44 XHHW-2 thermoset XLPE (90 °C)UL 1277 Type TC-ER |
| 3 | Core assembly & separator | Concentric cabled assembly with low-friction fleece or polyester binder tapeUL 1277 Type TC-ER |
| 4 | EMC metallic screen | Individually shielded brake/PTC pair + overall foil & ≥ 85% tinned Cu braidEMC ≥ 85% / 100% foil |
| 5 | Outer sheath | Black oil- & UV-resistant flame-retardant PVC/TPE jacketIEEE 1202 / FT4 Flame |
Colour-coded or numbered phase conductors with protective green/yellow earth under overall EMC screening.
Technical data
Sizes
| Power + Brake AWG | Outer Ø ≈ mm | Max. R20 Ω/km | Copper index kg/km | Weight ≈ kg/km | Min. bend R 10×D mm |
|---|---|---|---|---|---|
| 4×14 AWG + 2×16 AWG | 14.8 | 9.070 | 146 | 329 | 148 |
| 4×12 AWG + 2×16 AWG | 16.1 | 5.710 | 195 | 418 | 161 |
| 4×10 AWG + 2×16 AWG | 17.6 | 3.590 | 271 | 548 | 176 |
| 4×8 AWG + 2×16 AWG | 21.4 | 2.260 | 397 | 806 | 214 |
| 4×6 AWG + 2×16 AWG | 23.9 | 1.420 | 585 | 1,120 | 239 |
| 4×4 AWG + 2×16 AWG | 27.8 | 0.892 | 886 | 1,636 | 278 |
| 4×2 AWG + 2×14 AWG | 33.0 | 0.561 | 1,370 | 2,461 | 330 |
| 4×1/0 AWG + 2×14 AWG | 37.9 | 0.353 | 2,114 | 3,640 | 379 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC high-voltage dielectric test | 4 kV AC for 5 min without breakdown | Every manufactured drum |
| Conductor DC resistance test | Per ASTM B172 / B8 at 20 °C | Every drum length |
| Sample tests | ||
| EMC screen coverage & insulation check | Foil + TCWB continuity & wall thickness | Per production lot |
| Flame & environmental qualification | IEEE 1202 / FT4 Flame · UL Oil Res I/II | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.