Screened power & VFD / motor supply cablesIEEE 1580 Type P · UL TC-ER2,000 V · 110/125 °C XLPOOBS Dual Shield · Mud-Res XL-CPE

TP(OBS)-VFD 2 kV Type P Offshore Rig VFD Cable125 °C irradiated XLPO mud-resistant offshore rig VFD cable

Unarmored 2,000 V IEEE 1580 Type P offshore rig VFD power cable with flexible tinned copper, 125 °C irradiated XLPO insulation, Al/PET plus overall tinned copper braid (OBS), and mud-resistant irradiated XL-CPE Type N sheath.

Low-EMC design
EMC screen
Oil-resistant
Flame-retardant
Order designation
TP(OBS)-VFD 3×2 AWG + 3×10 AWG
Outer Ø
32.0 mm
Max. R20
0.561 Ω/km
Weight
2,277 kg/km
Min. bend R
192 mm
All sizes (15)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
2,000 V (2 kV)
110 °C IEEE 1580 / 125 °C XLPO
EMC screening
Al/PET + OBS
100% foil + tinned Cu braid (OBS)
Conductor temp.
+110/+125 °C
Irradiated XLPO dielectric margin
Mud resistance
NEK 606 Type N
Irradiated mud/oil-resistant XL-CPE
Min. bend radius
6 × OD
Unarmored extra-flexible rig routing
Size range
14 AWG–777 MCM
3+3 symmetrical flex tinned Cu

Typical values for this cable type, based on IEEE 1580 Type P · UL 1309 · UL 1277 TC-ER · NEK 606 Mud — confirmed in the datasheet and quotation for your order.

Application fit

Is TP(OBS)-VFD 2kV Type P right for your machine?

Unarmored 2,000 V IEEE 1580 Type P offshore rig VFD power cable with flexible tinned copper, 125 °C irradiated XLPO insulation, Al/PET plus overall tinned copper braid (OBS), and mud-resistant irradiated XL-CPE Type N sheath.

VFD inverter to AC motor screened feeder

Suitable

100% Al/PET foil plus overall tinned copper braid (OBS) and 3 green grounds contain high-power rig EMI.

Drilling jumbo & rotary mast feed

Suitable

125 °C irradiated XLPO raises ampacity for land and offshore rig SCR/VFD power houses.

Offshore mud pump & top drive

Suitable

NEK 606 irradiated XL-CPE (Type N) outer sheath resists synthetic oil-based drilling muds and brine.

Offshore platform & shipboard deck trays

Suitable

Unarmoured 6 × OD flexible IEEE 1580 Type P build routes cleanly across marine decks and rig trays.

Energy chain / drag chain

Not suitable

Engineered for rig trays and vibration-prone drives rather than continuous automated drag chains.

Use PUR-C-HF EMC

Motorised monospiral reel

Not suitable

Not rated for motorised cable reeling drums; specify a rubber reeling cable for spooled service.

Use RG / RG-D (N)SHTOEU-J
Typical machinesMarine & Offshore CableOffshore drilling rigs & drillshipsLand rig SCR / VFD power housesTop-drive, rotary & drawworks drivesMud-pump & shale-shaker circuitsFPSOs & petrochemical offshore decks

Construction

Layer by layer

Shown: TP(OBS)-VFD 2 kV Type P 3×2 AWG + 3×10 AWG — flexible tinned copper 125 °C black numbered XLPO phases and three green grounds inside Al/PET foil, OBS tinned copper braid, and irradiated XL-CPE sheath.

123456
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorExtra-flexible stranded tinned annealed copperIEEE 1580 Table 11 / ASTM B33 & B172
2Insulation & core ID125 °C irradiated cross-linked polyolefin (XLPO), black numberedBlack numbered phases + 3 × green XLPO grounds
3Separator tapePolyester barrier separator tape over 3+3 assemblyClean strip & thermal isolation
4Foil shieldAluminium/polyester foil tape (100% coverage)High-frequency EMI containment
5Overall braid shield (OBS)Overall tinned copper wire braid shield (OBS, ≥ 85%)Low-impedance EMC return shield
6Outer protective sheathBlack mud- & oil-resistant irradiated XL-CPE (Type N)IEEE 1580 / NEK 606 mud resistant

TP(OBS)-VFD 2 kV Type P

Three black numbered 125 °C XLPO phases + three symmetrical green grounds under Al/PET + OBS braid and XL-CPE Type N sheath (14 AWG–777 kcmil).

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEEE 1580 Type P · UL 1309 · UL 1277 TC-ER · NEK 606 Mud. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
2,000 V (2 kV) AC
Conductor class
IEEE 1580 Table 11 flex tinned Cu
Dual EMI shield
100% Al/PET foil + OBS TCWB (≥ 85%)

Thermal

Max. conductor temp.
+110 °C IEEE 1580 / +125 °C XLPO
Cold bend / impact
−40 °C bend / −35 °C impact
Min. bending radius
6 × OD (unarmored flexible)

Resistance

Flame test
IEEE 1202 / IEC 60332-3-22 Cat A
Mud & oil resistance
NEK 606 drilling-mud resistant XL-CPE
Ratings
IEEE 1580 Type P · UL 1309 · TC-ER

Sizes

3+3 Symmetrical (Type P OBS)
Phase + 3×
Ground (AWG)
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
6×D mm
3×14 AWG + 3×18 AWG16.19.07013636797
3×12 AWG + 3×16 AWG17.25.710187460103
3×10 AWG + 3×14 AWG18.63.590267600112
3×8 AWG + 3×12 AWG21.52.260396853129
3×6 AWG + 3×12 AWG23.71.4205391,111142
3×4 AWG + 3×12 AWG27.50.8927691,551165
3×2 AWG + 3×10 AWG32.00.5611,1792,277192
3×1 AWG + 3×8 AWG34.10.4451,5132,810205
3×1/0 AWG + 3×8 AWG36.50.3531,8263,339219
3×2/0 AWG + 3×6 AWG39.10.2802,3524,162235
3×4/0 AWG + 3×4 AWG46.10.1763,6866,322277
3×262 kcmil + 3×4 AWG51.10.1434,4067,609307
3×373 kcmil + 3×2 AWG57.60.1016,31210,587346
3×535 kcmil + 3×1 AWG67.90.0718,84314,804407
3×777 kcmil + 3×2/0 AWG77.80.04912,92921,135467
  • Conductor max. DC resistance R20 follows IEEE 1580 Table 11 / ASTM B172 flexible tinned copper at 20 °C.
  • Irradiated cross-linked polyolefin (XLPO) and XL-CPE Type N outer jacket provide superior drilling-mud and thermal overload endurance.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC high-voltage spark & tank testPer UL 1309 / IEEE 1580 2 kV ratingEvery manufactured reel
Conductor DC resistance checkPer IEEE 1580 Table 11 tinned copperEvery reel length
Sample tests
NEK 606 mud & cold-bend testDrilling-fluid ageing & −40 °C bendPer production lot
Vertical tray flame testIEEE 1202 / IEC 60332-3-22 Cat AType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEEE 1580 Type P (2,000 V / 110 °C–125 °C)UL 1309 Marine · UL 1277 Type TC-ERNEK 606 Mud Resistant · IEEE 1202 / FT4

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TP(OBS)-VFD 2kV TYPE P TEBAOFLEX.COM IEEE 1580 UL 1309 TC-ER [Size]
Delivery form
Cut-to-length or wooden export reels
Standard drum lengths
305 m (1,000 ft) · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-20
Updated
2026-11-20

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What does TP(OBS)-VFD stand for?
TP designates IEEE 1580 Type P marine/offshore construction, OBS specifies the Overall Braided Shield (tinned copper wire braid over 100% Al/PET foil), and VFD denotes the symmetrical 3-phase plus 3-ground drive geometry.
Why use electron-beam irradiated 125 °C XLPO and XL-CPE on drilling rigs?
Irradiation cross-linking improves thermal endurance (up to 125 °C conductor temperature), crush resistance, and immunity to synthetic oil-based drilling muds per NEK 606.
How is TP(OBS)-VFD different from armored Type P VFD cables?
TP(OBS)-VFD omits metallic basket-weave armour to minimize outer diameter, weight, and bend radius (6 × OD) for protected rig cableways and VFD house terminations.
How should the EMC shield and symmetrical grounds of TP(OBS)-VFD 2kV Type P be terminated?
Bond the metallic EMC shield circumferentially (360°) at both the inverter cabinet and motor terminal box using EMC cable glands or constant-force springs, and connect all protective ground conductors cleanly to the earth busbar.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for TP(OBS)-VFD 2kV Type P

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

TP(OBS)-VFD 2 kV Type P Offshore Rig VFD Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote