Immersion & wet locations
All-fluoropolymer FEP/ETFE construction resists concentrated acids, alkalis, hydrocarbons, landfill leachate and hot brine.
Product
S07E6E5-F 450/750 V heat- and chemical-resistant submersible pump cable combining Class 5 copper power conductors with E6 FEP insulation, ETFE-insulated thermal/leakage monitoring cores and an extruded E5 FEP fluoropolymer outer sheath.
Typical values for this cable type, based on EN 50525 / IEC 60228 Class 5 — confirmed in the datasheet and quotation for your order.
Application fit
S07E6E5-F 450/750 V heat- and chemical-resistant submersible pump cable combining Class 5 copper power conductors with E6 FEP insulation, ETFE-insulated thermal/leakage monitoring cores and an extruded E5 FEP fluoropolymer outer sheath.
All-fluoropolymer FEP/ETFE construction resists concentrated acids, alkalis, hydrocarbons, landfill leachate and hot brine.
Engineered for vertical suspension feeding submerged chemical pumps, mixers and agitators up to +150 °C.
Withstands hot industrial effluent and steam-cleaned sumps where NBR, PCP and EPDM rubbers swell or degrade.
Fluoropolymer sheath is formulated for chemical immersion and pump suspension, not high-cycle drag chains.
ARG7H1ORConstruction
Shown: S07E6E5-F (EN 50525 / IEC 60228 Class 5) featuring power conductors (4g16 mm²), power core insulation (e6) and outer sheath (e5) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Power Conductors (4G16 mm²) | Class 5 finely stranded plain annealed copper power conductors (3 phase cores + 1 green/yellow protective earth core)EN 50525 / IEC 60228 Class 5 |
| 2 | Power Core Insulation (E6) | Extruded fluorinated ethylene propylene (FEP, code E6) primary insulation resistant to aggressive solvents, acids, and +180 °C mediaEN 50525 / IEC 60228 Class 5 |
| 3 | Monitoring Conductors (2x1.5 mm²) | Two finely stranded plain copper auxiliary pilot conductors for submersible pump stator temperature and seal-leakage monitoringEN 50525 / IEC 60228 Class 5 |
| 4 | Monitoring Core Insulation | High-mechanical-strength ethylene tetrafluoroethylene (ETFE) fluoropolymer insulation over the 2 x 1.5 mm² control coresEN 50525 / IEC 60228 Class 5 |
| 5 | Outer Sheath (E5) | Heavy-duty black fluorinated ethylene propylene (FEP, code E5) outer jacket impervious to hot Leachate, hydrocarbons, and corrosive chemicalsEN 50525 / IEC 60228 Class 5 |
Built to EN 50525 / IEC 60228 Class 5 with power conductors (4g16 mm²) and outer sheath (e5)
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to EN 50525 / IEC 60228 Class 5 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| S07E6E5-F Construction Schedule (−50…+150 °C) | |||||||
| S07E6E5-F 4G6 + 2×1.5 mm² | 4G6 + 2×1.5 mm² | Class 5 Cu + FEP/ETFE | 16.4 | 485 | 3.2 | 135 | |
| S07E6E5-F 4G10 + 2×1.5 mm² | 4G10 + 2×1.5 mm² | Class 5 Cu + FEP/ETFE | 19.2 | 710 | 5.0 | 155 | |
| S07E6E5-F 4G16 + 2×1.5 mm² | 4G16 + 2×1.5 mm² | Class 5 Cu + FEP/ETFE | 22.5 | 1,040 | 7.8 | 180 | |
| S07E6E5-F 4G25 + 2×1.5 mm² | 4G25 + 2×1.5 mm² | Class 5 Cu + FEP/ETFE | 26.8 | 1,520 | 12.0 | 215 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 4G6 + 2×1.5 mm² | 3.30 | 450/750 V / 52 A | −50…+150 °C |
| 4G10 + 2×1.5 mm² | 1.91 | 450/750 V / 72 A | −50…+150 °C |
| 4G16 + 2×1.5 mm² | 1.21 | 450/750 V / 96 A | −50…+150 °C |
| 4G25 + 2×1.5 mm² | 0.78 | 450/750 V / 128 A | −50…+150 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (EN 50525 / IEC 60228 Class 5) | Electrical parameters and outer diameter within EN 50525 / IEC 60228 Class 5 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (EN 50525 / IEC 60228 Class 5) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (EN 50525 / IEC 60228 Class 5) | Verified structural and dielectric integrity across −50…+150 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.