Contact

AC Air-Cooled High-Current Welding Transformer Jumper120–630 mm² flexible air-cooled black rubber welding gun & press jumper

AC Welding Jumper combines ultra-fine Class 6 bare copper rope stranding with a flexible flame- and weld-spatter-resistant black chloroprene rubber sheath for resistance welding guns, presses, and heavy ground returns.

Oil-resistant
Flame-retardant
Approved
Order designation
AC Welding Jumper Cable 1×300 mm²
Outer Ø
31.0 mm
Max. R20
0.064 Ω/km
Weight
4,426 kg/km
Min. bend R
186 mm
All sizes (8)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Test voltage 2.5 kV AC
Temp. (fixed)
-30°C…+85°C
Flexing: -25 °C to +85 °C
Construction
PCP
Polyester separator tape + flexible
Min. bend radius
6 × OD
High-current flexible routing
Conductor
Bare Cu · Cl.6
Per EN 50525-2-81
Size range
1×120–1×630
8 standard configurations

Typical values for this cable type, based on EN 50525-2-81 · IEC 60245-6 · IEC 60228 Class 6 — confirmed in the datasheet and quotation for your order.

Application fit

Is AC Welding Jumper Cable right for your machine?

AC Welding Jumper combines ultra-fine Class 6 bare copper rope stranding with a flexible flame- and weld-spatter-resistant black chloroprene rubber sheath for resistance welding guns, presses, and heavy ground returns.

Fixed installation

Suitable

Durable 600 V PCP geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.

Motor stator, traction & converter leads

Suitable

Extra-flexible 600 V PCP stranding and 6×D bend radius connect dynamic welding guns, drives, and furnace feeders.

Welding power source & electrode lead

Suitable

Extra-flexible heat- and spatter-resistant 600 V PCP build delivers low-drop current to welding tongs and shop floor leads.

Factory automation tray & machine bus

Suitable

Flexible oil-resistant 600 V PCP construction routes cleanly along factory automation trays, machine frames, and production lines.

Energy chain / drag chain

Not suitable

600 V PCP construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

600 V PCP outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesPower transformers, switchgear & busduct jointsResistance welding guns & heavy fabrication shopsBESS battery racks, EV test benches & rectifiersSteel mills, foundries & high-current power bays

Construction

Layer by layer

Representative construction of AC Welding Jumper Cable: IEC 60228 Class 6 extra-flexible bare annealed copper, Polyester separator tape + flexible elastomeric chloroprene sheath, and Black flame-, oil- & weld-spatter-resistant PCP rubber outer sheath.

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorIEC 60228 Class 6 extra-flexible bare annealed copperIEC 60228 Class 6
2Cooling core / primary dielectricPolyester separator tape + flexible elastomeric chloroprene sheathEN 50525-2-81
3Outer sheath / hoseBlack flame-, oil- & weld-spatter-resistant PCP rubber outer sheathHigh-Cycle Weld Flexing

AC Welding Jumper Cable High-Duty

Single-core high-duty construction protected by Black flame-, oil- & weld-spatter-resistant PCP rubber outer sheath.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on EN 50525-2-81 · IEC 60245-6 · IEC 60228 Class 6. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
600 V
Test voltage
2.5 kV AC
Conductor
Bare Cu · Cl.6
Core / dielectric
Polyester separator tape + flexible
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-30 °C to +85 °C
Temp. range (flexing)
-25 °C to +85 °C
Peak / short-circuit
+160 °C (5 s)
Min. bending radius
6 × OD

Resistance

Primary performance
High-Cycle Weld Flexing
Environment / duty
Oil & Spatter Resistant PCP
Mechanical / special
Low Voltage Drop
Outer finish
Black flame-, oil- &

Sizes

Air-Cooled High-Current Sizes (mm²)
Cross-section
mm²
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
6×D mm
1×120 mm²22.10.1611,1521,838133
1×150 mm²23.90.1291,4402,272143
1×185 mm²25.80.1061,7762,777155
1×240 mm²28.50.0802,3043,569171
1×300 mm²31.00.0642,8804,426186
1×400 mm²34.80.0493,8405,856209
1×500 mm²38.10.0384,8007,280229
1×630 mm²41.90.0296,0489,125251
  • Conductor DC resistance R20 at 20 °C per IEC 60228 Class 6.
  • Minimum bending radius calculated at 6 × nominal outer diameter (OD). Custom terminations available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric withstand test2.5 kV AC without breakdownEvery manufactured length
Continuity & conductor DC resistancePer IEC 60228 Class 6 at 20 °CEvery drum / assembly
Sample tests
Tensile, dimensional & pressure checkRated -30 °C to +85 °C continuousPer production lot
Environmental, thermal & mechanical qualificationHigh-Cycle Weld Flexing · Oil & Spatter Resistant PCPType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

EN 50525-2-81IEC 60245-6IEC 60228 Class 6EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

AC Welding Jumper Cable 600 V TEBAOFLEX.COM [EN 50525-2-81] [Size] [Metre mark]
Delivery form
Custom assemblies, coils or export drums
Standard lengths
Cut-to-length · 100 m · 500 m · 1,000 m
MOQ
1 assembly / 50 m (stock) · 300 m (custom)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-23
Updated
2026-11-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes AC Welding Jumper Cable suited for demanding 600 V installations?
AC Welding Jumper Cable combines IEC 60228 Class 6 extra-flexible bare annealed copper with Polyester separator tape + flexible elastomeric chloroprene sheath and Black flame-, oil- & weld-spatter-resistant PCP rubber outer sheath. Ultra-fine stranding cuts operator wrist fatigue and endures continuous robotic and manual spot-welding duty.
What minimum bending radius should be respected for AC Welding Jumper Cable?
Maintain a minimum bending radius of 6 × OD across -25 °C to +85 °C flexing temperatures to ensure long mechanical and dielectric service life.
Can AC Welding Jumper Cable be delivered pre-terminated with custom lugs, water fittings, or subsea connectors?
Yes. TEBAOFLEX supplies AC Welding Jumper Cable either in bulk lengths or factory-assembled with copper lugs, water-cooled swivel fittings, or molded subsea wet-mate connectors.
What quality tests and certificates accompany every shipment of AC Welding Jumper Cable?
AC Welding Jumper Cable conforms to EN 50525-2-81, IEC 60245-6, IEC 60228 Class 6 (High-Cycle Weld Flexing) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for AC Welding Jumper Cable

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

AC Air-Cooled High-Current Welding Transformer Jumper

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote