NYIFY 300/500 V Flat Webbed PVC Under-Plaster Installation CableDIN VDE 0250-201 · 300/500 V · -5 °C to +70 °C industrial NYIFY construction

NYIFY 300/500 V Flat Webbed PVC Under-Plaster Installation Cable (NYIFY) engineered to DIN VDE 0250-201 for 300/500 V service across -5 °C to +70 °C, featuring stranded copper conductor and white pvc webbed outer sheath with minimum bending radius 6 × OD.

Approved
Flame-retardant
Oil-resistant
Order designation
NYIFY 4G2.5
Outer Ø ≈
10.8 mm
Total weight ≈
186 kg/km
Min. bend R (fixed)
86 mm
Configuration
4 × 2.5 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
Per DIN VDE 0250-201
Operating temp.
−5…+70 °C
Continuous thermal rating
Min. bend radius
6 × OD
Installed / fixed routing
Conductor
copper conductor
High-conductivity copper conductor
Outer layer
White PVC webbed
Extruded White PVC webbed outer
Standard
DIN VDE 0250-201
DIN VDE 0250-201

Typical values for this cable type, based on DIN VDE 0250-201 — confirmed in the datasheet and quotation for your order.

Application fit

Is NYIFY right for your machine?

NYIFY 300/500 V Flat Webbed PVC Under-Plaster Installation Cable (NYIFY) engineered to DIN VDE 0250-201 for 300/500 V service across -5 °C to +70 °C, featuring stranded copper conductor and white pvc webbed outer sheath with minimum bending radius 6 × OD.

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with DIN VDE 0250-201.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 6 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesBuilding & Fire SafetyCommercial & Residential Building DistributionData Centers & Public InfrastructureFire-Safe Evacuation & Riser ShaftsIndustrial Plant Balance-of-Plant Wiring

Construction

Layer by layer

Shown: NYIFY (DIN VDE 0250-201) with stranded copper conductor, pvc core insulation and white pvc webbed outer sheath (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper conductorHigh-conductivity copper conductor per DIN VDE 0250-201DIN VDE 0250-201
2PVC core insulationExtruded PVC dielectric (individual core / group layer)DIN VDE 0250-201
3White PVC webbed outer sheathExtruded White PVC webbed outer sheath protective layer (continuous layer)DIN VDE 0250-201

NYIFY — Standard Execution

Built to DIN VDE 0250-201 with stranded copper conductor and white pvc webbed outer sheath

NYIFY — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per DIN VDE 0250-201

NYIFY — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0250-201. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
300/500 V (DIN VDE 0250-201)
Conductor construction
Stranded copper conductor — High-conductivity copper conductor per DIN VDE 0250-201
Primary insulation / dielectric
PVC core insulation — Extruded PVC dielectric (individual core / group layer)

Thermal

Continuous operating temperature
−5…+70 °C per DIN VDE 0250-201
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
White PVC webbed outer sheath — Extruded White PVC webbed outer sheath protective layer (continuous layer)
Minimum bending radius
6 × OD (installed / static routing)
Layer count & geometry
3 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with DIN VDE 0250-201
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
DIN VDE 0250-201
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
NYIFY
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard NYIFY cable sizes

Manufactured to DIN VDE 0250-201 across standard single-core and multi-core cross-sections.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
NYIFY Standard Production Schedule (300/500 V · −5…+70 °C)
NYIFY 3G1.53 × 1.5 mm²8.410568
NYIFY 4G1.54 × 1.5 mm²9.212874
NYIFY 5G1.55 × 1.5 mm²10.115681
NYIFY 3G2.53 × 2.5 mm²9.814878
NYIFY 4G2.54 × 2.5 mm²10.818686
NYIFY 5G2.55 × 2.5 mm²11.922895
NYIFY 4G44 × 4.0 mm²12.6268101
NYIFY 4G64 × 6.0 mm²14.2365114
NYIFY 4G104 × 10 mm²17.5580140
NYIFY 4G164 × 16 mm²20.4845163
NYIFY 4G254 × 25 mm²24.81,290198
NYIFY 4G354 × 35 mm²27.91,710223
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Single-core and multi-core sizes from 0.5 mm² up to 630 mm² (or AWG/kcmil) available per DIN VDE 0250-201.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (DIN VDE 0250-201)DC resistance at 20 °C and geometry within DIN VDE 0250-201 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (DIN VDE 0250-201)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (DIN VDE 0250-201)Full compliance with DIN VDE 0250-201 across −5…+70 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0250-201 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX NYIFY <size> DIN VDE 0250-201 300/500 V CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define NYIFY (NYIFY 300/500 V Flat Webbed PVC Under-Plaster Installation Cable)?
NYIFY (NYIFY 300/500 V Flat Webbed PVC Under-Plaster Installation Cable) is manufactured in accordance with DIN VDE 0250-201 for 300/500 V service over -5 °C to +70 °C. Its 3-layer construction comprises stranded copper conductor, pvc core insulation, white pvc webbed outer sheath.
What is the minimum bending radius and installation temperature for NYIFY?
The minimum installed bending radius for NYIFY is 6 × OD across its continuous operating temperature range of -5 °C to +70 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of NYIFY arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper conductor (High-conductivity copper conductor per DIN VDE 0250-201); (02) PVC core insulation (Extruded PVC dielectric (individual core / group layer)); (03) White PVC webbed outer sheath (Extruded White PVC webbed outer sheath protective layer (continuous layer)).
What factory test certificates are supplied with NYIFY?
Every production drum or spool of NYIFY undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per DIN VDE 0250-201, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for NYIFY

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

NYIFY 300/500 V Flat Webbed PVC Under-Plaster Installation Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote