SANS Standard Cables

South African type-series reeling, trailing and screened mining cables.

How does the cable move?

Pick one or more duties — the list below updates.

10 sans standard cables

Voltage
Standard
Sheath
Features

Reeling cables

Wind on and off motorised reels and drums on cranes, stackers and mining machines.

3 cables
Type 611 — end cross section
Type 611SANS Type 611 / 611-ECC 6.35/11 kV Reeling Cable
6.35/11 kV – 19/33 kV
Motorised reel, multi-layer drum, trailing, submerged
SANSRubber
6.35/11 kV – 19/33 kV, SANS, Rubber sheathMotorised reel, multi-layer drum, trailing, submerged
Type 622 — end cross section
Type 622SANS Type 622 / 622-ECC 12.7/22 kV Reeling Mining Cable
12.7/22 kV
Motorised reel, multi-layer drum, trailing, submerged
SANSRubber
12.7/22 kV, SANS, Rubber sheathMotorised reel, multi-layer drum, trailing, submerged
Type 63 — end cross section
Type 63SANS Type 63 1.9/3.3 kV Flexible Trailing Mining Cable
1.9/3.3 kV
Motorised reel, multi-layer drum, trailing, submerged
SANSRubber
1.9/3.3 kV, SANS, Rubber sheathMotorised reel, multi-layer drum, trailing, submerged

Trailing cables

Flexible power cables dragged behind mobile mining and material-handling machines.

2 cables
MGM 115 Type 11 / 14 / 16 — cable cross-section
MGM 115 Type 11 / 14 / 16MGM 115 Type 11 / 14 / 16 Elastomeric-Cradle Coal-Cutter Cable
300/500 V
Trailing, submerged
IECRubber
300/500 V, IEC, Rubber sheathTrailing, submerged
MGM 115 Type 7 / 7M / 7S — cable cross-section
MGM 115 Type 7 / 7M / 7SMGM 115 Type 7 / 7M / 7S Central-Earth Coal-Cutter Cable
300/500 V
Trailing, submerged
IECRubber
300/500 V, IEC, Rubber sheathTrailing, submerged

Rubber cables

Rubber-insulated, rubber-sheathed cables for mobile and heavy-duty service.

5 cables
Type 41 — end cross section
Type 41SANS Type 41 640/1100 V Flexible Trailing Cable
640/1100 V
Motorised reel, multi-layer drum, trailing, submerged
SANSRubber
640/1100 V, SANS, Rubber sheathMotorised reel, multi-layer drum, trailing, submerged
Type 61A — end cross section
Type 61ASANS Type 61A 640/1100 V Mining Trailing Cable
640/1100 V
Motorised reel, multi-layer drum, trailing, submerged
SANSPUR
640/1100 V, SANS, PUR sheathMotorised reel, multi-layer drum, trailing, submerged
Type 61B — end cross section
Type 61BSANS Type 61B 0.64/1.1 kV Screened Mining Cable
0.64/1.1 kV
Trailing, fixed, submerged
SANSRubber
0.64/1.1 kV, SANS, Rubber sheathTrailing, fixed, submerged
Type 633 — end cross section
Type 633SANS Type 633 / 633-ECC 19/33 kV Reeling Mining Cable
19/33 kV
Motorised reel, multi-layer drum, trailing, submerged
SANSRubber
19/33 kV, SANS, Rubber sheathMotorised reel, multi-layer drum, trailing, submerged
Type 66 — end cross section
Type 66SANS Type 66 / 66-ECC 3.8/6.6 kV Mining Trailing Cable
3.8/6.6 kV
Motorised reel, multi-layer drum, trailing, submerged
SANSRubber
3.8/6.6 kV, SANS, Rubber sheathMotorised reel, multi-layer drum, trailing, submerged

Choosing sans standard cables

Four things decide most selections. Our engineers check the rest against your application.

01 · Mechanical duty & installation profile

  • Match minimum bending radius, travel speed, and tensile load to the active duty profile (Motorised monospiral reel, Cylindrical / multi-layer drum, Trailing & towing, Fixed installation).
  • For continuous reeling, festoon, or drag-chain motion, specify fine-stranded Class 5/6 copper conductors with central strain-relief or anti-torsion braid.

02 · Rated voltage & cable family scope

  • This collection spans Reeling cables, Trailing cables, Rubber cables, grouped below so power feeders, control circuits, and data/optical links can be specified side by side.
  • Account for voltage drop, ambient temperature derating, and symmetrical EMC screening on long runs or VFD motor drives.

03 · Standards compliance & outer sheath compound

  • Verify the governing regional or industry standard required by the project specification (IEC, VDE/DIN, UL, BS, ICEA/MSHA, etc.).
  • Use the outer-sheath filter to lock in PUR, heavy-duty EPR/PCP rubber, or low-smoke zero-halogen (LSZH) compounds for oil, abrasion, or fire safety.
Filter the range by standard

Questions buyers ask

Not covered here? Send your drawing and an engineer replies within 2 business hours.

Ask on WhatsApp
What rated voltages are available in the SANS Standard Cables category?

Rated voltages run from 640/1100 V to 19/33 kV across all 10 products. The most common rating is 640/1100 V, listed for 4 products.

Which standards do the products in the SANS Standard Cables category reference?

The products reference SANS Standard (all 10 products), BS 6708 (2 products), and IEC Standard (2 products).

Are PDF datasheets available for the products in the SANS Standard Cables category?

Yes. All 10 products have a PDF datasheet, linked from each product card and product page.

Engineering reference

Background on how sans standard cables are built, rated and specified.

Read the full reference

The SANS Standard Cables collection brings together 10 industrial cable models across Reeling cables, Trailing cables, Rubber cables. South African type-series reeling, trailing and screened mining cables.

Use the multi-facet filter bar and duty matrix view to compare rated voltage, governing standard, outer sheath compound, and mechanical duty ratings side by side, or add candidate models to a combined engineering enquiry.

Compare cables

Voltage
Standard
Sheath
Features
Typical use

Highlighted rows differ between the selected cables.

Filters

Duty

Voltage

Standard

Sheath

Features