AC Induction 1,000 V 450 °C Air-Cooled High-Current Cable450 °C 1,000 V nickel-plated copper mica-glass heavy induction furnace lead

AC Induction 1,000 V 450 °C wraps heavy-gauge nickel-plated copper strands in overlapping phlogopite mica tapes and a double grey fibreglass outer braid for air-cooled 1,000 V induction heating and kiln feeders.

Flame-retardant
Oil-resistant
Approved
Order designation
AC Induction 1000V 450°C Cable 1×70 mm²
Outer Ø
14.7 mm
Max. R20
0.305 Ω/km
Weight
1,181 kg/km
Min. bend R
147 mm
All sizes (10)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1000 V
Test voltage 4 kV AC
Temp. (fixed)
-60°C…+450°C
Flexing: -40 °C to +400 °C
Construction
Mica + Glass
Multi-layer overlapping phlogopite
Min. bend radius
10 × OD
High-current flexible routing
Conductor
Nickel-Plated Cu
Per IEC 60228 Class 5
Size range
1×16–1×240
10 standard configurations

Typical values for this cable type, based on IEC 60228 Class 5 · DIN VDE 0250 (ref.) · ASTM B355 Nickel Cu — confirmed in the datasheet and quotation for your order.

Application fit

Is AC Induction 1000V 450°C Cable right for your machine?

AC Induction 1,000 V 450 °C wraps heavy-gauge nickel-plated copper strands in overlapping phlogopite mica tapes and a double grey fibreglass outer braid for air-cooled 1,000 V induction heating and kiln feeders.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 1000 V Mica build delivers stable high-current power near furnaces, ovens, kilns, and molten-metal zones.

Fixed installation

Suitable

Durable 1000 V Mica geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.

High-temperature boiler & thermal plant

Suitable

Thermal-aged 1000 V Mica insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.

Cable trench & heavy drive bay

Suitable

Rugged 1000 V Mica construction handles stationary heavy-plant cable trenches, rolling-mill feeders, and industrial power bays.

Energy chain / drag chain

Not suitable

1000 V Mica construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

1000 V Mica outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesSteelworks, rolling mills & aluminum smeltersIndustrial ovens, ceramic kilns & glassworksCommercial heating elements & cartridge heatersPower plants, boiler rooms & hot switchgear

Construction

Layer by layer

Representative construction of AC Induction 1000V 450°C Cable: ASTM B355 Class K stranded nickel-plated copper (27% Ni high-temp), Multi-layer overlapping phlogopite mica tape dielectric (1,000 V), and Grey high-temperature double-braided fibreglass outer jacket (mica/glass).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorASTM B355 Class K stranded nickel-plated copper (27% Ni high-temp)ASTM B355 Nickel Cu
2Mica / PTFE tape dielectricMulti-layer overlapping phlogopite mica tape dielectric (1,000 V)IEC 60228 Class 5
3Fibreglass outer braidGrey high-temperature double-braided fibreglass outer jacket (mica/glass)450 °C Continuous Air-Cooled

AC Induction 1000V 450°C Cable Mica-Glass

Single high-temperature conductor wrapped in overlapping thermal dielectric tape and varnished fibreglass outer braid.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60228 Class 5 · DIN VDE 0250 (ref.) · ASTM B355 Nickel Cu. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
1000 V
Test voltage
4 kV AC
Conductor
Nickel-Plated Cu
Core / dielectric
Multi-layer overlapping phlogopite mica
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-60 °C to +450 °C
Temp. range (flexing)
-40 °C to +400 °C
Peak / short-circuit
+600 °C (short-term)
Min. bending radius
10 × OD

Resistance

Primary performance
450 °C Continuous Air-Cooled
Environment / duty
1,000 V Mica Dielectric
Mechanical / special
Double Fibreglass Braid
Outer finish
Grey high-temperature double-braided

Sizes

High-Temp Mica-Glass Single-Core (mm²)
Conductor
mm²
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
10×D mm
1×16 mm²8.71.35515429887
1×25 mm²10.10.874240448101
1×35 mm²11.30.621336611113
1×50 mm²12.90.432480856129
1×70 mm²14.70.3056721,181147
1×95 mm²16.60.2319121,584166
1×120 mm²18.30.1801,1521,987183
1×150 mm²20.10.1451,4402,469201
1×185 mm²21.90.1191,7763,026219
1×240 mm²24.50.0902,3043,902245
  • Conductor DC resistance R20 at 20 °C per ASTM B355 Nickel Cu.
  • Minimum bending radius calculated at 10 × nominal outer diameter (OD). Custom terminations available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric withstand test4 kV AC without breakdownEvery manufactured length
Continuity & conductor DC resistancePer ASTM B355 Nickel Cu at 20 °CEvery drum / assembly
Sample tests
Tensile, dimensional & pressure checkRated -60 °C to +450 °C continuousPer production lot
Environmental, thermal & mechanical qualification450 °C Continuous Air-Cooled · 1,000 V Mica DielectricType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60228 Class 5DIN VDE 0250 (ref.)ASTM B355 Nickel CuEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

AC Induction 1000V 450°C Cable 1000 V TEBAOFLEX.COM [IEC 60228 Class 5] [Size] [Metre mark]
Delivery form
Custom assemblies, coils or export drums
Standard lengths
Cut-to-length · 100 m · 500 m · 1,000 m
MOQ
1 assembly / 50 m (stock) · 300 m (custom)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-23
Updated
2026-11-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes AC Induction 1000V 450°C Cable suited for demanding 1000 V installations?
AC Induction 1000V 450°C Cable combines ASTM B355 Class K stranded nickel-plated copper (27% Ni high-temp) with Multi-layer overlapping phlogopite mica tape dielectric (1,000 V) and Grey high-temperature double-braided fibreglass outer jacket (mica/glass). Air-cooled 1,000 V mica-glass construction withstands 450 °C continuous ambient heat around induction coils.
What minimum bending radius should be respected for AC Induction 1000V 450°C Cable?
Maintain a minimum bending radius of 10 × OD across -40 °C to +400 °C flexing temperatures to ensure long mechanical and dielectric service life.
Can AC Induction 1000V 450°C Cable be delivered pre-terminated with custom lugs, water fittings, or subsea connectors?
Yes. TEBAOFLEX supplies AC Induction 1000V 450°C Cable either in bulk lengths or factory-assembled with copper lugs, water-cooled swivel fittings, or molded subsea wet-mate connectors.
What quality tests and certificates accompany every shipment of AC Induction 1000V 450°C Cable?
AC Induction 1000V 450°C Cable conforms to IEC 60228 Class 5, DIN VDE 0250 (ref.), ASTM B355 Nickel Cu (450 °C Continuous Air-Cooled) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for AC Induction 1000V 450°C Cable

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

AC Induction 1,000 V 450 °C Air-Cooled High-Current Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote