Fixed installation
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Product
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Typical values for this cable type, based on Reference specification per NF C 32-321 / IEC 60502-1 (U-3000 AR3V / U-1000 AR3V 1.8/3kV NF C 32-321) — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.
Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.
Outer sheath compound resists industrial oils, moisture ingress, abrasion and outdoor weathering.
Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.
Use TRA 0.6/1 kV PUR Reeling CableScreened 1.8/3 kV XLPE/PE construction suppresses electromagnetic interference on shared industrial power and PLC signal trays.
Construction
Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | 1×240 mm² RM Class 2 Compacted Al |
| 2 | Insulation & Core Identification | U-3000 AR3V 1.8/3kV thick-wall XLPE primary insulation (240 mm² Compacted Al) |
| 3 | Screen / Bedding / Armour Layer | 2.2 mm thick-wall 1.8/3 (3.6) kV XLPE dielectric moisture-resistant interface (NF C 32-321) |
| 4 | Outer Protective Sheath | Black UV-resistant Polyethylene (PE) / PVC outer sheath (OD 27.6 mm) |
Class 2 Compacted Stranded Aluminium · Outer diameter 27.6 mm
Class 2 Compacted Stranded Aluminium · Outer diameter 32.6 mm
Class 2 Compacted Stranded Aluminium · Outer diameter 38.1 mm
Technical data
Sizes
Representative configurations from the series specification; select a row to prefill the quotation tool.
| Configuration | Conductor & shield | Insulation / wall | Outer sheath | Outer diameter mm | Min. bend radius mm | Max. conductor resistance @ 20 °C Ω/km | Conductor weight kg/km | Cable weight kg/km | Key electrical / optical rating | Part designation | Enquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| U-3000 AR3V / U-1000 AR3V 1.8/3kV NF C 32-321 | |||||||||||
| 1×240 mm² | Class 2 Compacted Stranded Aluminium | U-3000 AR3V 1.8/3kV thick-wall XLPE primary insulation | Outdoor PE | 27.6 | 414 | 0.12 | 477.7 | 1,257 | 336 A | U-3000 AR3V / U-1000 AR3V 1.8/3kV NF C 32-321 (1×240 mm²) | |
| 1×300 mm² | Class 2 Compacted Stranded Aluminium | U-3000 AR3V 1.8/3kV thick-wall XLPE primary insulation | Outdoor PE | 32.6 | 489 | 0.09 | 665.0 | 1,750 | 385 A | U-3000 AR3V / U-1000 AR3V 1.8/3kV NF C 32-321 (1×300 mm²) | |
| 1×400 mm² | Class 2 Compacted Stranded Aluminium | U-3000 AR3V 1.8/3kV thick-wall XLPE primary insulation | Outdoor PE | 38.1 | 572 | 0.07 | 909.7 | 2,394 | 445 A | U-3000 AR3V / U-1000 AR3V 1.8/3kV NF C 32-321 (1×400 mm²) | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & continuity | Within maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228 | Every manufactured drum length |
| Dielectric withstand / spark test | No breakdown across insulation, screen or armour | Every manufactured drum length |
| Sample tests | ||
| Vertical flame propagation & jacket qualification | Self-extinguishing and compliant with reference standard limits | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.