Contact

Li-09YSCH PiMF-100 & Hybrid DATA 500m Submersible Smart Pump CableDIN EN 60079 / Cat.5 · 300/500 V · 500 m ex-rated submersible smart pump cat.5 &

Li-09YSCH PiMF-100 Cat.5 (Subsea DATA) & Hybrid DATA 300/500 V 500m Submersible Dual-Screened Smart Pump Sensor Data & Control XL-Copolymer Cable (DIN EN 60079 / Cat.5, 300/500 V, -40 °C to +90 °C, min. bend radius 8 × OD).

Water-resistant
EMC screen
Low-EMC design
Flame-retardant
Order designation
LI-09YSCH PIMF-100 Config A (Compact)
Outer Ø ≈
10.4 mm
Net weight ≈
155 kg/km
Tensile rating ≈
4.5 kN
Core / stranding
Stranded tinned Cu (IEC 60228 / ASTM)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
Tested per DIN EN 60079 / Cat.5
Operating temp.
−40…+90 °C
Continuous subsea & marine service
Min. bend radius
8 × OD
Dynamic sheave & fixed routing
Core / conductor
4×2 Cat.5
Cat.5 PiMF data pairs
Outer protection
XL-Copolymer
Overall SnCu braid
Standard
DIN EN 60079
DIN EN 60079-14

Typical values for this cable type, based on DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard — confirmed in the datasheet and quotation for your order.

Application fit

Is LI-09YSCH PIMF-100 & HYBRID DATA right for your machine?

Li-09YSCH PiMF-100 Cat.5 (Subsea DATA) & Hybrid DATA 300/500 V 500m Submersible Dual-Screened Smart Pump Sensor Data & Control XL-Copolymer Cable (DIN EN 60079 / Cat.5, 300/500 V, -40 °C to +90 °C, min. bend radius 8 × OD).

Immersion & wet locations

Suitable

Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.

Offshore platform & shipboard deck trays

Suitable

Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.

Fixed installation

Suitable

Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.

Motor stator, traction & converter leads

Suitable

Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.

Typical machinesNaval Shipboard & Submarine OutboardOffshore Cathodic Protection (ICCP)Underwater Welding & Nuclear PoolsDeep-Well & Seabed Pump Feeders

Construction

Layer by layer

Shown: LI-09YSCH PIMF-100 & HYBRID DATA (DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard) featuring dual-screened data core (pimf / 2×2 quad), 300/500 v epr control cores (4×1.5 mm²) and cross-linked copolymer sheath (500 m) (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Dual-Screened Data Core (PiMF / 2×2 Quad)4×2 Cat.5 Foam-Skin PP PiMF (Li-09YSCH) or 2×2 PE + Al/PET foil + tinned Cu braid + TPU
2300/500 V EPR Control Cores (4×1.5 mm²)Four numbered Class 5 copper control cores with EPR insulation in Subsea Hybrid DATA
3Overall Tinned Copper Braid ScreenHigh-coverage overall tinned copper wire braid for VFD & Ex-area EMC immunity
4Cross-Linked Copolymer Sheath (500 m)Oil-, sewage- and flame-resistant halogen-free XL Copolymer outer jacket (–40 °C to +90 °C)

LI-09YSCH PIMF-100 & HYBRID DATA — Standard Subsea & Marine Execution

Built to DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard with dual-screened data core (pimf / 2×2 quad) and cross-linked copolymer sheath (500 m)

LI-09YSCH PIMF-100 & HYBRID DATA — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

LI-09YSCH PIMF-100 & HYBRID DATA — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
300/500 V (DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard)
Core / conductor construction
Dual-Screened Data Core (PiMF / 2×2 Quad) — 4×2 Cat.5 Foam-Skin PP PiMF (Li-09YSCH) or 2×2 PE + Al/PET foil + tinned Cu braid + TPU
Primary dielectric / buffering
300/500 V EPR Control Cores (4×1.5 mm²) — Four numbered Class 5 copper control cores with EPR insulation in Subsea Hybrid DATA

Thermal

Continuous operating temperature
−40…+90 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Cross-Linked Copolymer Sheath (500 m) — Oil-, sewage- and flame-resistant halogen-free XL Copolymer outer jacket (–40 °C to +90 °C)
Minimum bending radius
8 × OD
Hydrostatic, tensile & crush duty
Overall Tinned Copper Braid Screen — High-coverage overall tinned copper wire braid for VFD & Ex-area EMC immunity

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
LI-09YSCH PIMF-100 & HYBRID DATA
Sheath colour & metre marking
Continuous metre-marked black outer finish (XL-Copolymer (500 m))
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard LI-09YSCH PIMF-100 & HYBRID DATA subsea & marine configurations

Manufactured to DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
LI-09YSCH PIMF-100 & HYBRID DATA Construction Schedule (−40…+90 °C)
LI-09YSCH PIMF-100 Config A (Compact)4×2×24 AWG + 2×18 AWG (or 4C)Stranded tinned Cu (IEC 60228 / ASTM)10.41554.585
LI-09YSCH PIMF-100 Config B (Standard)4×2×20 AWG + 4×16 AWG (or 8C)Stranded tinned Cu (IEC 60228 / ASTM)13.32659.6110
LI-09YSCH PIMF-100 Config C (Heavy Hybrid)8×2×20 AWG + 4×12 AWG (or 12C)Stranded tinned Cu (IEC 60228 / ASTM)16.642018.5140
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard)DC resistance at 20 °C / optical attenuation and outer diameter within DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard)Zero dielectric breakdown and verified insulation resistance for 300/500 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard)Verified submersion integrity, tensile load and thermal stability across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN EN 60079 / Cat.5 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX LI-09YSCH PIMF-100 & HYBRID DATA DIN EN 60079 / Cat.5 300/500 V CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define LI-09YSCH PIMF-100 & HYBRID DATA (Li-09YSCH PiMF-100 & Hybrid DATA 500m Submersible Smart Pump Cable)?
LI-09YSCH PIMF-100 & HYBRID DATA (Li-09YSCH PiMF-100 & Hybrid DATA 500m Submersible Smart Pump Cable) is manufactured in accordance with DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard for 300/500 V service over -40 °C to +90 °C. Its 4-layer construction comprises dual-screened data core (pimf / 2×2 quad), 300/500 v epr control cores (4×1.5 mm²) and cross-linked copolymer sheath (500 m).
What is the minimum bending radius and operating temperature range for LI-09YSCH PIMF-100 & HYBRID DATA?
The minimum bending radius for LI-09YSCH PIMF-100 & HYBRID DATA is 8 × OD across its continuous operating temperature range of -40 °C to +90 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of LI-09YSCH PIMF-100 & HYBRID DATA arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Dual-Screened Data Core (PiMF / 2×2 Quad) — 4×2 Cat.5 Foam-Skin PP PiMF (Li-09YSCH) or 2×2 PE + Al/PET foil + tinned Cu braid + TPU; (02) 300/500 V EPR Control Cores (4×1.5 mm²) — Four numbered Class 5 copper control cores with EPR insulation in Subsea Hybrid DATA; (03) Overall Tinned Copper Braid Screen — High-coverage overall tinned copper wire braid for VFD & Ex-area EMC immunity; (04) Cross-Linked Copolymer Sheath (500 m) — Oil-, sewage- and flame-resistant halogen-free XL Copolymer outer jacket (–40 °C to +90 °C).
What factory test certificates are supplied with LI-09YSCH PIMF-100 & HYBRID DATA?
Every production drum of LI-09YSCH PIMF-100 & HYBRID DATA undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for LI-09YSCH PIMF-100 & HYBRID DATA

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

Li-09YSCH PiMF-100 & Hybrid DATA 500m Submersible Smart Pump Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote