Immersion & wet locations
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Product
Li-09YSCH PiMF-100 Cat.5 (Subsea DATA) & Hybrid DATA 300/500 V 500m Submersible Dual-Screened Smart Pump Sensor Data & Control XL-Copolymer Cable (DIN EN 60079 / Cat.5, 300/500 V, -40 °C to +90 °C, min. bend radius 8 × OD).
Typical values for this cable type, based on DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard — confirmed in the datasheet and quotation for your order.
Application fit
Li-09YSCH PiMF-100 Cat.5 (Subsea DATA) & Hybrid DATA 300/500 V 500m Submersible Dual-Screened Smart Pump Sensor Data & Control XL-Copolymer Cable (DIN EN 60079 / Cat.5, 300/500 V, -40 °C to +90 °C, min. bend radius 8 × OD).
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.
Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.
Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.
Outboard marine and feeder construction is not designed for high-speed crane festoon trolleys.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: LI-09YSCH PIMF-100 & HYBRID DATA (DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard) featuring dual-screened data core (pimf / 2×2 quad), 300/500 v epr control cores (4×1.5 mm²) and cross-linked copolymer sheath (500 m) (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Dual-Screened Data Core (PiMF / 2×2 Quad) | 4×2 Cat.5 Foam-Skin PP PiMF (Li-09YSCH) or 2×2 PE + Al/PET foil + tinned Cu braid + TPU |
| 2 | 300/500 V EPR Control Cores (4×1.5 mm²) | Four numbered Class 5 copper control cores with EPR insulation in Subsea Hybrid DATA |
| 3 | Overall Tinned Copper Braid Screen | High-coverage overall tinned copper wire braid for VFD & Ex-area EMC immunity |
| 4 | Cross-Linked Copolymer Sheath (500 m) | Oil-, sewage- and flame-resistant halogen-free XL Copolymer outer jacket (–40 °C to +90 °C) |
Built to DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard with dual-screened data core (pimf / 2×2 quad) and cross-linked copolymer sheath (500 m)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| LI-09YSCH PIMF-100 & HYBRID DATA Construction Schedule (−40…+90 °C) | |||||||
| LI-09YSCH PIMF-100 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| LI-09YSCH PIMF-100 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| LI-09YSCH PIMF-100 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 300/500 V (45–100 Ω data) | −40…+90 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 300/500 V (45–100 Ω data) | −40…+90 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 300/500 V (High-Power Hybrid) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard) | Zero dielectric breakdown and verified insulation resistance for 300/500 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (DIN EN 60079-14 / ISO/IEC 11801 Cat.5 Smart Pump Standard) | Verified submersion integrity, tensile load and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.