VFD inverter to AC motor screened feeder
600 × 0.10 mm enamelled Litz stranding suppresses skin and proximity losses in 10–200 kHz resonant converters.
Product
HSC-1-2SSUB-0 1 kVAC screened high-frequency power cable featuring twin 4.7 mm² (600 × 0.10 mm enamelled copper Litz) conductors, flexible silicone dielectric, silicone bedding, tinned copper EMC braid screen and a black PUR jacket.
Typical values for this cable type, based on IEC 60317 / DIN VDE 0250 — confirmed in the datasheet and quotation for your order.
Application fit
HSC-1-2SSUB-0 1 kVAC screened high-frequency power cable featuring twin 4.7 mm² (600 × 0.10 mm enamelled copper Litz) conductors, flexible silicone dielectric, silicone bedding, tinned copper EMC braid screen and a black PUR jacket.
600 × 0.10 mm enamelled Litz stranding suppresses skin and proximity losses in 10–200 kHz resonant converters.
Silicone core insulation and tough TPE-U (PUR) outer sheath endure repetitive flexing on automated tooling.
Tinned copper braid screen contains high-frequency magnetic and capacitive switching emissions.
Silicone cores withstand +180 °C, while the outer PUR jacket limits continuous ambient duty to +90 °C.
Construction
Shown: HSC-1-2SSUB-0 (IEC 60317 / DIN VDE 0250) featuring high-frequency litz conductors, primary core dielectric and outer jacket (-0 black) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | High-Frequency Litz Conductors | Two 4.7 mm² high-frequency Litz conductors (600 x 0.10 mm individually enamelled copper strands) minimizing skin and proximity lossesIEC 60317 / DIN VDE 0250 |
| 2 | Primary Core Dielectric | High-flexibility extruded silicone rubber core insulation rated for 1 kVAC operating / 3 kVAC test voltageIEC 60317 / DIN VDE 0250 |
| 3 | Interstitial Bedding | Extruded silicone elastomer compound filling the twin-core interstices for a circular cross-sectionIEC 60317 / DIN VDE 0250 |
| 4 | EMC Braid Screen | Overall tinned copper wire braid electromagnetic screen suppressing high-frequency switching emissionsIEC 60317 / DIN VDE 0250 |
| 5 | Outer Jacket (-0 Black) | Abrasion-, oil-, and hydrolysis-resistant black thermoplastic polyurethane (TPE-U / PUR) outer jacket (OD 12.1 mm)IEC 60317 / DIN VDE 0250 |
Built to IEC 60317 / DIN VDE 0250 with high-frequency litz conductors and outer jacket (-0 black)
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to IEC 60317 / DIN VDE 0250 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| HSC-1-2SSUB-0 Construction Schedule (−40…+90 °C) | |||||||
| HSC-1-2SSUB-0 2×2.5 mm² Litz | 2 × 2.5 mm² (320×0.10 mm) | 320×0.10 mm Cu Litz | 9.8 | 135 | 0.9 | 60 | |
| HSC-1-2SSUB-0 2×4.7 mm² Litz | 2 × 4.7 mm² (600×0.10 mm) | 600×0.10 mm Cu Litz | 12.1 | 215 | 1.6 | 75 | |
| HSC-1-2SSUB-0 2×8.0 mm² Litz | 2 × 8.0 mm² (1020×0.10 mm) | 1020×0.10 mm Cu Litz | 14.8 | 335 | 2.7 | 90 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 2 × 2.5 mm² Litz | 7.60 | 1 kVAC (3 kVAC test) / 32 A HF | −40…+90 °C |
| 2 × 4.7 mm² Litz | 3.98 | 1 kVAC (3 kVAC test) / 50 A HF | −40…+90 °C |
| 2 × 8.0 mm² Litz | 2.35 | 1 kVAC (3 kVAC test) / 72 A HF | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (IEC 60317 / DIN VDE 0250) | Electrical parameters and outer diameter within IEC 60317 / DIN VDE 0250 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (IEC 60317 / DIN VDE 0250) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (IEC 60317 / DIN VDE 0250) | Verified structural and dielectric integrity across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.