Fixed installation
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Product
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Typical values for this cable type, based on Reference specification per SS 424 14 16 / HD 620 (FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620) — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.
Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.
Outer sheath compound resists industrial oils, moisture ingress, abrasion and outdoor weathering.
Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.
Use TRA 0.6/1 kV PUR Reeling CableHigh-dielectric 12/20 kV XLPE/PE construction feeds medium- and high-voltage substation duct banks, transformer bays, and utility feeders.
Construction
Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | 3×95/25 mm² Watertight Compacted Cu |
| 2 | Insulation & Core Identification | SS 424 14 16 triple-extruded XLPE insulation (95 mm² Watertight Copper) |
| 3 | Screen / Bedding / Armour Layer | Semi-conductive water-swellable bedding tape + Collective annealed copper wire screen (25 mm²) + counter-helix tape + Aluminium/PE laminate moisture barrier |
| 4 | Outer Protective Sheath | Black Polyethylene (PE) outer sheath (OD 54.0 mm) |
Class 2 Stranded Plain Copper · Outer diameter 54.0 mm
Class 2 Stranded Plain Copper · Outer diameter 63.7 mm
Class 2 Stranded Plain Copper · Outer diameter 74.5 mm
Technical data
Sizes
Representative configurations from the series specification; select a row to prefill the quotation tool.
| Configuration | Conductor & shield | Insulation / wall | Outer sheath | Outer diameter mm | Min. bend radius mm | Max. conductor resistance @ 20 °C Ω/km | Copper weight kg/km | Cable weight kg/km | Key electrical / optical rating | Part designation | Enquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620 | |||||||||||
| 3×95/25 mm² | Class 2 Stranded Plain Copper | SS 424 14 16 triple-extruded XLPE insulation | Outdoor PE | 54.0 | 810 | 0.19 | 3,563.6 | 6,853 | 244 A | FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620 (3×95/25 mm²) | |
| 3×120/25 mm² | Class 2 Stranded Plain Copper | SS 424 14 16 triple-extruded XLPE insulation | Outdoor PE | 63.7 | 956 | 0.15 | 4,961.8 | 9,542 | 282 A | FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620 (3×120/25 mm²) | |
| 3×150/25 mm² | Class 2 Stranded Plain Copper | SS 424 14 16 triple-extruded XLPE insulation | Outdoor PE | 74.5 | 1,118 | 0.12 | 6,786.0 | 13,050 | 324 A | FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620 (3×150/25 mm²) | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & continuity | Within maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228 | Every manufactured drum length |
| Dielectric withstand / spark test | No breakdown across insulation, screen or armour | Every manufactured drum length |
| Sample tests | ||
| Vertical flame propagation & jacket qualification | Self-extinguishing and compliant with reference standard limits | Type qualification & periodic lot audit |
Marking & supply
Sheath marking