FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620 manufactured to SS 424 14 16 / HD 620, rated 6/10 (12) kV – 12/20 (24) kV and -25°C to +90°C with a 15 × OD minimum bending radius for renewable energy installations.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Flame-retardant
EMC screen
Outdoor & humid
Approved
Order designation
FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620 (3×95/25 mm²)
Outer diameter
54.0 mm
Cable weight
6,853 kg/km
Min. bend radius
810 mm
Conductor & shield
Class 2 Stranded Plain Copper
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
6/10–12/20 kV
SS 424 14 16 / HD 620
Temperature
-25°C to +90°C
Fixed / flex duty
Min. bend radius
15 × OD
54.0–74.5 mm
Screening
Cu Wire Screen
Concentric copper wire & tape screen
Outer sheath
Outdoor PE
UV-stabilized moisture-barrier PE
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per SS 424 14 16 / HD 620 (FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620) — confirmed in the datasheet and quotation for your order.

Application fit

Is FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620 right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.

Motor stator, traction & converter leads

Suitable

Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

Offshore platform & shipboard deck trays

Suitable

Outer sheath compound resists industrial oils, moisture ingress, abrasion and outdoor weathering.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Substation MV/HV underground duct bank

Suitable

High-dielectric 12/20 kV XLPE/PE construction feeds medium- and high-voltage substation duct banks, transformer bays, and utility feeders.

Typical machinesRenewable Energy & EV ChargingPower distribution & utility networksRailways, tunnels & public infrastructureProcess instrumentation & oil/gas skidsIndustrial automation & control cabinetsRenewable energy, marine & heavy industry

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620 – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
1Conductor3×95/25 mm² Watertight Compacted Cu
2Insulation & Core IdentificationSS 424 14 16 triple-extruded XLPE insulation (95 mm² Watertight Copper)
3Screen / Bedding / Armour LayerSemi-conductive water-swellable bedding tape + Collective annealed copper wire screen (25 mm²) + counter-helix tape + Aluminium/PE laminate moisture barrier
4Outer Protective SheathBlack Polyethylene (PE) outer sheath (OD 54.0 mm)

3×95/25 mm²

Class 2 Stranded Plain Copper · Outer diameter 54.0 mm

3×120/25 mm²

Class 2 Stranded Plain Copper · Outer diameter 63.7 mm

3×150/25 mm²

Class 2 Stranded Plain Copper · Outer diameter 74.5 mm

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per SS 424 14 16 / HD 620 (FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
6/10 (12) kV – 12/20 (24) kV
Conductor & core insulation
3×95/25 mm² Watertight Compacted Cu · SS 424 14 16 triple-extruded XLPE insulation (95 mm² Watertight Copper)
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
-25°C to +90°C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
SS 424 14 16 / HD 620

Mechanical

Minimum bending radius
15 × OD
Screening / armour architecture
Semi-conductive water-swellable bedding tape + Collective annealed copper wire screen (25 mm²) + counter-helix tape + Aluminium/PE laminate moisture barrier
Outer sheath material & colour
Black Polyethylene (PE) outer sheath (OD 54.0 mm)

Reference standards

Reference standard
SS 424 14 16 / HD 620
Hazardous Substance Compliance
CE, UKCA, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620
3×95/25 mm²Class 2 Stranded Plain CopperSS 424 14 16 triple-extruded XLPE insulationOutdoor PE54.08100.193,563.66,853244 AFXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620 (3×95/25 mm²)
3×120/25 mm²Class 2 Stranded Plain CopperSS 424 14 16 triple-extruded XLPE insulationOutdoor PE63.79560.154,961.89,542282 AFXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620 (3×120/25 mm²)
3×150/25 mm²Class 2 Stranded Plain CopperSS 424 14 16 triple-extruded XLPE insulationOutdoor PE74.51,1180.126,786.013,050324 AFXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620 (3×150/25 mm²)
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228Every manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation, screen or armourEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing and compliant with reference standard limitsType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

SS 424 14 16 / HD 620 CompliantEN 10204 3.1 Factory Test CertificateCE, UKCA, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620 / TEBAOFLEX.COM — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
250 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-04
Updated
2026-11-04

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620 designed for?
FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620 is engineered for renewable energy installations under SS 424 14 16 / HD 620, operating over -25°C to +90°C with a minimum bending radius of 15 × OD.
How is FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620 constructed across its layers?
Its 4-layer architecture combines 3×95/25 mm² Watertight Compacted Cu with SS 424 14 16 triple-extruded XLPE insulation (95 mm² Watertight Copper), Semi-conductive water-swellable bedding tape + Collective annealed copper wire screen (25 mm²) + counter-helix tape + Aluminium/PE laminate moisture barrier and Black Polyethylene (PE) outer sheath (OD 54.0 mm).
What standards and routine factory tests apply to FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620?
Every manufactured drum is tested to SS 424 14 16 / HD 620 for conductor continuity, dielectric voltage withstand and sheath integrity, supplied with an EN 10204 3.1 inspection certificate.
What sizes and drum lengths are available for FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620?
Representative sizes include 3×95/25 mm², 3×120/25 mm² and 3×150/25 mm², supplied on 250 m, 500 m or 1,000 m export drums or custom cut lengths.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

FXLJ-F / FXQJ 12/20(24)kV SS 424 14 16 / HD 620

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote