Immersion & wet locations
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Product
0.6/1 kV KTW (Kiwa) & EC 2002/72 Certified PVC-Insulated Bright-Blue Water-Impermeable PE-Sheathed Drinking-Water & Food-Zone Pump Cable (UBA KTW / EC 2002/72, 0.6/1 kV, -20 °C to +70 °C, min. bend radius 8 × OD).
Typical values for this cable type, based on German UBA KTW (Kiwa) & EC Directive 2002/72/EC Food Zone — confirmed in the datasheet and quotation for your order.
Application fit
0.6/1 kV KTW (Kiwa) & EC 2002/72 Certified PVC-Insulated Bright-Blue Water-Impermeable PE-Sheathed Drinking-Water & Food-Zone Pump Cable (UBA KTW / EC 2002/72, 0.6/1 kV, -20 °C to +70 °C, min. bend radius 8 × OD).
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.
Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.
Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.
Outboard marine and feeder construction is not designed for high-speed crane festoon trolleys.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: 0.6/1 KV (KTW / FOOD ZONE) (German UBA KTW (Kiwa) & EC Directive 2002/72/EC Food Zone) featuring class 5 flexible bare copper (3g–4g 1.5–2.5), 0.6/1 kv pvc core insulation (hd 308 s2) and bright-blue water-impermeable pe sheath (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 5 Flexible Bare Copper (3G–4G 1.5–2.5) | Finely stranded annealed plain copper conductors for drinking-water & food-zone pumps |
| 2 | 0.6/1 kV PVC Core Insulation (HD 308 S2) | High-dielectric PVC insulation color-coded Brown, Black, Grey & Green/Yellow (3.5 kV test) |
| 3 | Bright-Blue Water-Impermeable PE Sheath | Lead-free smooth PE jacket certified to German KTW (Kiwa) & EC 2002/72 food contact (150 m) |
Built to German UBA KTW (Kiwa) & EC Directive 2002/72/EC Food Zone with class 5 flexible bare copper (3g–4g 1.5–2.5) and bright-blue water-impermeable pe sheath
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to German UBA KTW (Kiwa) & EC Directive 2002/72/EC Food Zone for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 0.6/1 KV (KTW / FOOD ZONE) Construction Schedule (−20…+70 °C) | |||||||
| 0.6 4G16 mm² | 4G16 mm² (3×16 + 1G16) | IEC 60228 Class 5 flexible Cu/SnCu | 21.8 | 840 | 2.4 | 130 | |
| 0.6 4G35 mm² | 4G35 mm² (3×35 + 1G16) | IEC 60228 Class 5 flexible Cu/SnCu | 28.6 | 1,620 | 5.2 | 172 | |
| 0.6 3×70 + 3G16 mm² | 3 × 70 mm² + 3G16 mm² | IEC 60228 Class 5 flexible Cu/SnCu | 38.4 | 3,180 | 10.5 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4G16 mm² (3×16 + 1G16) | 1.21 | 0.6/1 kV (94 A submerged) | −20…+70 °C |
| 4G35 mm² (3×35 + 1G16) | 0.55 | 0.6/1 kV (152 A submerged) | −20…+70 °C |
| 3 × 70 mm² + 3G16 mm² | 0.27 | 0.6/1 kV (235 A submerged) | −20…+70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (German UBA KTW (Kiwa) & EC Directive 2002/72/EC Food Zone) | DC resistance at 20 °C / optical attenuation and outer diameter within German UBA KTW (Kiwa) & EC Directive 2002/72/EC Food Zone tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (German UBA KTW (Kiwa) & EC Directive 2002/72/EC Food Zone) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (German UBA KTW (Kiwa) & EC Directive 2002/72/EC Food Zone) | Verified submersion integrity, tensile load and thermal stability across −20…+70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.