Fixed installation
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Product
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Typical values for this cable type, based on Reference specification per SFS 5636 / HD 620-10F (AHXAMK-W / AHXCMK-WTC 12/20(24)kV SFS 5636) — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.
Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.
Outer sheath compound resists industrial oils, moisture ingress, abrasion and outdoor weathering.
Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.
Use TRA 0.6/1 kV PUR Reeling CableHigh-dielectric 12/20 kV XLPE/PE construction feeds medium- and high-voltage substation duct banks, transformer bays, and utility feeders.
Construction
Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | 3×1×95 mm² + 35 mm² Cu/Al Screen + 62 mm² Messenger |
| 2 | Insulation & Core Identification | SFS 5636 triple-extruded XLPE insulation (95 mm² Watertight Aluminium) |
| 3 | Metallic Phase Screen | 3 × 35 mm² Aluminum phase screens over extruded semi-con |
| 4 | Triplex Laid-Up Phase Sheaths | Triplex laid-up weather-resistant Black PE phase sheaths + galvanized steel messenger |
Class 2 Stranded Aluminium / Copper · Outer diameter 65.0 mm
Class 2 Stranded Aluminium / Copper · Outer diameter 76.7 mm
Class 2 Stranded Aluminium / Copper · Outer diameter 89.7 mm
Technical data
Sizes
Representative configurations from the series specification; select a row to prefill the quotation tool.
| Configuration | Conductor & shield | Insulation / wall | Outer sheath | Outer diameter mm | Min. bend radius mm | Max. conductor resistance @ 20 °C Ω/km | Conductor weight kg/km | Cable weight kg/km | Key electrical / optical rating | Part designation | Enquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| AHXAMK-W / AHXCMK-WTC 12/20(24)kV SFS 5636 | |||||||||||
| 1×95 mm² | Class 2 Stranded Aluminium / Copper | SFS 5636 triple-extruded XLPE insulation | Outdoor PE | 65.0 | 975 | 0.19 | 5,163.1 | 9,929 | 244 A | AHXAMK-W / AHXCMK-WTC 12/20(24)kV SFS 5636 (1×95 mm²) | |
| 1×120 mm² | Class 2 Stranded Aluminium / Copper | SFS 5636 triple-extruded XLPE insulation | Outdoor PE | 76.7 | 1,150 | 0.15 | 7,189.0 | 13,825 | 282 A | AHXAMK-W / AHXCMK-WTC 12/20(24)kV SFS 5636 (1×120 mm²) | |
| 1×150 mm² | Class 2 Stranded Aluminium / Copper | SFS 5636 triple-extruded XLPE insulation | Outdoor PE | 89.7 | 1,346 | 0.12 | 9,832.2 | 18,908 | 324 A | AHXAMK-W / AHXCMK-WTC 12/20(24)kV SFS 5636 (1×150 mm²) | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & continuity | Within maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228 | Every manufactured drum length |
| Dielectric withstand / spark test | No breakdown across insulation, screen or armour | Every manufactured drum length |
| Sample tests | ||
| Vertical flame propagation & jacket qualification | Self-extinguishing and compliant with reference standard limits | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.