UL 854 Type SER 600 V Round Service-Entrance Cable (XHHW-2)UL 854 / NEC Article 338 · 600 V · -40 °C to +90 °C industrial SER construction

UL 854 Type SER 600 V Round Service-Entrance Cable with XHHW-2 Conductors (SER) engineered to UL 854 / NEC Article 338 for 600 V service across -40 °C to +90 °C, featuring stranded copper conductor and pvc outer jacket with minimum bending radius 6 × OD.

Approved
Outdoor & humid
Ozone, UV & moisture
Water-resistant
Order designation
SER 4G2.5
Outer Ø ≈
10.8 mm
Total weight ≈
186 kg/km
Min. bend R (fixed)
86 mm
Configuration
4 × 2.5 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Per UL 854 / NEC Article 338
Operating temp.
−40…+90 °C
Continuous thermal rating (UL 854)
Min. bend radius
6 × OD
Installed / fixed routing
Conductor
copper conductor
High-conductivity copper conductor
Outer layer
PVC outer jacket
Extruded PVC outer jacket protective
Standard
UL 854
UL 854 / NEC Article 338

Typical values for this cable type, based on UL 854 / NEC Article 338 — confirmed in the datasheet and quotation for your order.

Application fit

Is SER right for your machine?

UL 854 Type SER 600 V Round Service-Entrance Cable with XHHW-2 Conductors (SER) engineered to UL 854 / NEC Article 338 for 600 V service across -40 °C to +90 °C, featuring stranded copper conductor and pvc outer jacket with minimum bending radius 6 × OD.

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with UL 854 / NEC Article 338.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 6 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesBuilding & Fire SafetyCommercial & Residential Building DistributionData Centers & Public InfrastructureFire-Safe Evacuation & Riser ShaftsIndustrial Plant Balance-of-Plant Wiring

Construction

Layer by layer

Shown: SER (UL 854 / NEC Article 338) with stranded copper conductor, xlpe core insulation and pvc outer jacket (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper conductorHigh-conductivity copper conductor per UL 854 / NEC Article 338UL 854 / NEC Article 338
2XLPE core insulationExtruded XLPE dielectric (individual core / group layer)UL 854 / NEC Article 338
3Reinforcement binderHelically applied reinforcement binderUL 854 / NEC Article 338
4PVC outer jacketExtruded PVC outer jacket protective layer (continuous layer)UL 854 / NEC Article 338

SER — Standard Execution

Built to UL 854 / NEC Article 338 with stranded copper conductor and pvc outer jacket

SER — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per UL 854 / NEC Article 338

SER — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL 854 / NEC Article 338. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
600 V (UL 854 / NEC Article 338)
Conductor construction
Stranded copper conductor — High-conductivity copper conductor per UL 854 / NEC Article 338
Primary insulation / dielectric
XLPE core insulation — Extruded XLPE dielectric (individual core / group layer)

Thermal

Continuous operating temperature
−40…+90 °C per UL 854 / NEC Article 338
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
PVC outer jacket — Extruded PVC outer jacket protective layer (continuous layer)
Minimum bending radius
6 × OD (installed / static routing)
Layer count & geometry
4 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with UL 854 / NEC Article 338
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
UL 854 / NEC Article 338
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
SER
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard SER cable sizes

Manufactured to UL 854 / NEC Article 338 across standard single-core and multi-core cross-sections.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
SER Standard Production Schedule (600 V · −40…+90 °C)
SER 3G1.53 × 1.5 mm²8.410568
SER 4G1.54 × 1.5 mm²9.212874
SER 5G1.55 × 1.5 mm²10.115681
SER 3G2.53 × 2.5 mm²9.814878
SER 4G2.54 × 2.5 mm²10.818686
SER 5G2.55 × 2.5 mm²11.922895
SER 4G44 × 4.0 mm²12.6268101
SER 4G64 × 6.0 mm²14.2365114
SER 4G104 × 10 mm²17.5580140
SER 4G164 × 16 mm²20.4845163
SER 4G254 × 25 mm²24.81,290198
SER 4G354 × 35 mm²27.91,710223
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Single-core and multi-core sizes from 0.5 mm² up to 630 mm² (or AWG/kcmil) available per UL 854 / NEC Article 338.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (UL 854 / NEC Article 338)DC resistance at 20 °C and geometry within UL 854 / NEC Article 338 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (UL 854 / NEC Article 338)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (UL 854 / NEC Article 338)Full compliance with UL 854 / NEC Article 338 across −40…+90 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL 854 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX SER <size> UL 854 600 V CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define SER (UL 854 Type SER 600 V Round Service-Entrance Cable with XHHW-2 Conductors)?
SER (UL 854 Type SER 600 V Round Service-Entrance Cable with XHHW-2 Conductors) is manufactured in accordance with UL 854 / NEC Article 338 for 600 V service over -40 °C to +90 °C. Its 4-layer construction comprises stranded copper conductor, xlpe core insulation, reinforcement binder, pvc outer jacket.
What is the minimum bending radius and installation temperature for SER?
The minimum installed bending radius for SER is 6 × OD across its continuous operating temperature range of -40 °C to +90 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of SER arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper conductor (High-conductivity copper conductor per UL 854 / NEC Article 338); (02) XLPE core insulation (Extruded XLPE dielectric (individual core / group layer)); (03) Reinforcement binder (Helically applied reinforcement binder); (04) PVC outer jacket (Extruded PVC outer jacket protective layer (continuous layer)).
What factory test certificates are supplied with SER?
Every production drum or spool of SER undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per UL 854 / NEC Article 338, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for SER

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

UL 854 Type SER 600 V Round Service-Entrance Cable (XHHW-2)

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote