Fixed installation
Compacted Class 2 aluminum or Class 5/K copper conductors with XLPE/EPR/HEPR insulation install cleanly in vertical tower cleats and trays
Product
0.6/1 kV Multi-Core (3C / 3.5C / 4C) Stranded Aluminum EBXL-XLPE / HFFR LSZH Fixed Wind Turbine Tower Cable (IEC 60502-1 / IEC 60332-3) engineered for 0.6/1 kV wind turbine service across -40 to +105 °C (min. bend radius 10 × OD).
Typical values for this cable type, based on IEC 60502-1 & IEC 60332-3 Multi-Core Aluminum EBXL-XLPE/HFFR Wind Tower Specification — confirmed in the datasheet and quotation for your order.
Application fit
0.6/1 kV Multi-Core (3C / 3.5C / 4C) Stranded Aluminum EBXL-XLPE / HFFR LSZH Fixed Wind Turbine Tower Cable (IEC 60502-1 / IEC 60332-3) engineered for 0.6/1 kV wind turbine service across -40 to +105 °C (min. bend radius 10 × OD).
Compacted Class 2 aluminum or Class 5/K copper conductors with XLPE/EPR/HEPR insulation install cleanly in vertical tower cleats and trays
Flexible DLO 2 kV, WTTC 1 kV and blade grounding builds absorb nacelle yaw loop torsion and rotor blade flexing down to −40 °C.
NSGAFOU 1.8/3 kV short-circuit-proof and UL WTTC/RHW-2 feeders wire directly into nacelle converter cabinets and tower base switchgear.
Heavy-duty CPE, HM4/HFFR LSZH and 5GM3 polychloroprene jackets resist turbine hydraulic oil, condensation, salt spray and UV.
Wind tower power feeders and large-cross-section DLO cables are not intended for high-cycle factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: 0.6/1 kV Multi-Core AL EBXL-XLPE/HFFR (IEC 60502-1 & IEC 60332-3 Multi-Core Aluminum EBXL-XLPE/HFFR Wind Tower Specification) featuring stranded aluminum conductors (3c / 3.5c / 4c), ebxl-xlpe cross-linked polyethylene insulation and hffr / hf-po zero-halogen outer sheath (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Aluminum Conductors (3C / 3.5C | Lightweight aluminum phase & neutral conductors (16-400 mm²) |
| 2 | EBXL-XLPE Cross-Linked Polyethylene Insu | High-thermal-stability electron-beam cross-linked XLPE |
| 3 | HFFR / HF-PO Zero-Halogen Outer Sheath | Flame-retardant low-smoke polyolefin jacket for tower distribution |
Built to IEC 60502-1 & IEC 60332-3 Multi-Core Aluminum EBXL-XLPE/HFFR Wind Tower Specification with stranded aluminum conductors (3c / 3.5c / 4c) and hffr / hf-po zero-halogen outer sheath
Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths
Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report
Technical data
Sizes
Manufactured to IEC 60502-1 & IEC 60332-3 Multi-Core Aluminum EBXL-XLPE/HFFR Wind Tower Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 0.6/1 kV Multi-Core AL EBXL-XLPE/HFFR Construction Schedule (−40…+105 °C) | |||||||
| 0.6/1 kV Multi-Core AL 1×150 / 4×95 Al | 1 × 150 mm² (or 4 × 95 mm² Al) | Class 2 Compacted Al / Class 5 AA8000 | 23.5 | 640 | 10.5 | 190 | |
| 0.6/1 kV Multi-Core AL 1×240 / 4×150 Al | 1 × 240 mm² (or 4 × 150 mm² Al) | Class 2 Compacted Al / Class 5 AA8000 | 28.4 | 980 | 16.8 | 230 | |
| 0.6/1 kV Multi-Core AL 1×400 / 4×240 Al | 1 × 400 mm² (or 4 × 240 mm² Al) | Class 2 Compacted Al / Class 5 AA8000 | 35.8 | 1,590 | 28.0 | 290 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 1 × 150 mm² (or 4 × 95 mm² Al) | 0.21 | 0.6/1 kV (315 A Al) | −40…+105 °C |
| 1 × 240 mm² (or 4 × 150 mm² Al) | 0.13 | 0.6/1 kV (435 A Al) | −40…+105 °C |
| 1 × 400 mm² (or 4 × 240 mm² Al) | 0.08 | 0.6/1 kV (590 A Al) | −40…+105 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (IEC 60502-1 & IEC 60332-3 Multi-Core Aluminum EBXL-XLPE/HFFR Wind Tower Specification) | DC resistance at 20 °C and insulation/sheath wall thickness within IEC 60502-1 & IEC 60332-3 Multi-Core Aluminum EBXL-XLPE/HFFR Wind Tower Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (IEC 60502-1 & IEC 60332-3 Multi-Core Aluminum EBXL-XLPE/HFFR Wind Tower Specification) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Low-temperature drip-loop torsion, oil & flame qualification (IEC 60502-1 & IEC 60332-3 Multi-Core Aluminum EBXL-XLPE/HFFR Wind Tower Specification) | Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+105 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.