Offshore platform & shipboard deck trays
Halogen-free SHF1/SHF2, IEEE 1580 Type P or PE/PP submarine outer serving withstands marine salt mist, drilling mud and seabed/deck duty.
Product
CIR UL 2225 TC-ER-HL & UL 1309 600 V Crush- & Impact-Resistant Class I Div 1 Hazardous Marine Cable (UL 2225 TC-ER-HL / UL 1309) engineered for 600 V (0.6/1 kV) service across -40 to +110 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification — confirmed in the datasheet and quotation for your order.
Application fit
CIR UL 2225 TC-ER-HL & UL 1309 600 V Crush- & Impact-Resistant Class I Div 1 Hazardous Marine Cable (UL 2225 TC-ER-HL / UL 1309) engineered for 600 V (0.6/1 kV) service across -40 to +110 °C (min. bend radius 6 × OD).
Halogen-free SHF1/SHF2, IEEE 1580 Type P or PE/PP submarine outer serving withstands marine salt mist, drilling mud and seabed/deck duty.
Approved for submarine seabed burial, J-tube pull-in, offshore platform cable ladders and shipboard bulkhead penetrations.
Extruded lead-alloy radial water barrier or cross-linked marine elastomer sheath prevents moisture ingress in subsea and wet-deck service.
Compacted copper or extra-flexible Class I/K tinned copper conductors terminate cleanly into offshore switchboards, transformers and thrus
Submarine and armoured offshore power cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: CIR TC-ER-HL 600V (UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification) featuring stranded tinned copper conductors (4 cores), 90°c/110 °c xlpo core insulation and oil-resistant cpe / lszh outer sheath (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Tinned Copper Conductors (4 Cor | 3 power cores + 1 ground conductor (18 AWG to 500 MCM) |
| 2 | 90°C/110 °C XLPO Core Insulation | Flame-retardant cross-linked polyolefin insulation |
| 3 | CIR Polymeric Crush & Impact Inner Barri | High-strength armorless polymeric barrier rated for Class I Div 1 HL |
| 4 | Oil-Resistant CPE / LSZH Outer Sheath | Heavy-duty flame-retardant outer jacket for deck winches & hazardous zones |
Built to UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification with stranded tinned copper conductors (4 cores) and oil-resistant cpe / lszh outer sheath
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| CIR TC-ER-HL 600V Construction Schedule (−40…+110 °C) | |||||||
| CIR TC-ER-HL 600V 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (or 1C×50 mm²) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 18.5 | 135 | |
| CIR TC-ER-HL 600V 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (or 1C×150 mm²) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 32.0 | 175 | |
| CIR TC-ER-HL 600V 3×95+1G50 mm² | 3 × 95 + 1G50 mm² (or 1C×300 mm²) | IEC 60228 Class 2/5 Cu/SnCu | 41.2 | 3,680 | 58.0 | 250 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (or 1C×50 mm²) | 1.15 | 600 V (0.6/1 kV) (98 A) | −40…+110 °C |
| 3 × 35 + 1G16 mm² (or 1C×150 mm²) | 0.52 | 600 V (0.6/1 kV) (158 A) | −40…+110 °C |
| 3 × 95 + 1G50 mm² (or 1C×300 mm²) | 0.19 | 600 V (0.6/1 kV) (285 A) | −40…+110 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification) | Zero dielectric breakdown and verified insulation resistance for 600 V (0.6/1 kV) rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+110 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.