Contact
submarine & offshore power composite cableUL 2225 TC-ER-HL / UL 1309600 V (0.6/1 kV) (-40 to +110 °C)Oil-Resistant CPE / LSZH Outer Sheat

CIR UL 2225 TC-ER-HL & UL 1309 600 V Crush- & Impact-Resistant Class I Div 1 Hazardous Marine CableUL 2225 TC-ER-HL / UL 1309 — 600 V (0.6/1 kV) — -40 to +110 °C Subsea & Offshore Cable

CIR UL 2225 TC-ER-HL & UL 1309 600 V Crush- & Impact-Resistant Class I Div 1 Hazardous Marine Cable (UL 2225 TC-ER-HL / UL 1309) engineered for 600 V (0.6/1 kV) service across -40 to +110 °C (min. bend radius 6 × OD).

Water-resistant
Flame-retardant
Oil-resistant
Approved
Order designation
CIR TC-ER-HL 600V 3×16+1G16 mm²
Outer Ø ≈
22.4 mm
Net weight ≈
920 kg/km
Tensile rating ≈
18.5 kN
Core / stranding
IEC 60228 Class 2/5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V (0.6/1 kV)
Tested per UL 2225 TC-ER-HL / UL 1309
Operating temp.
−40…+110 °C
Continuous subsea & offshore service
Min. bend radius
6 × OD
Winch sheave, chute & seabed routing
Core / conductor
Stranded Tinned
3 power cores + 1 ground conductor (18 A
Outer protection
Oil-Resistant CP
Heavy-duty flame-retardant outer jacket
Standard
UL 2225 TC-ER-HL
UL 2225 Type TC-ER-HL & UL 1309 Class I

Typical values for this cable type, based on UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is CIR TC-ER-HL 600V right for your machine?

CIR UL 2225 TC-ER-HL & UL 1309 600 V Crush- & Impact-Resistant Class I Div 1 Hazardous Marine Cable (UL 2225 TC-ER-HL / UL 1309) engineered for 600 V (0.6/1 kV) service across -40 to +110 °C (min. bend radius 6 × OD).

Offshore platform & shipboard deck trays

Suitable

Halogen-free SHF1/SHF2, IEEE 1580 Type P or PE/PP submarine outer serving withstands marine salt mist, drilling mud and seabed/deck duty.

Fixed installation

Suitable

Approved for submarine seabed burial, J-tube pull-in, offshore platform cable ladders and shipboard bulkhead penetrations.

Immersion & wet locations

Suitable

Extruded lead-alloy radial water barrier or cross-linked marine elastomer sheath prevents moisture ingress in subsea and wet-deck service.

Motor stator, traction & converter leads

Suitable

Compacted copper or extra-flexible Class I/K tinned copper conductors terminate cleanly into offshore switchboards, transformers and thrus

Energy chain / drag chain

Not suitable

Submarine and armoured offshore power cable is not designed for high-cycle automation drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableOffshore Wind Inter-Array & Export Submarine LinksSubsea Island & Platform HV/MV Power InterconnectsOffshore Oil & Gas Drilling Rigs & FPSOsCommercial Vessels, Polar Ships & Marine Propulsion

Construction

Layer by layer

Shown: CIR TC-ER-HL 600V (UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification) featuring stranded tinned copper conductors (4 cores), 90°c/110 °c xlpo core insulation and oil-resistant cpe / lszh outer sheath (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded Tinned Copper Conductors (4 Cor3 power cores + 1 ground conductor (18 AWG to 500 MCM)
290°C/110 °C XLPO Core InsulationFlame-retardant cross-linked polyolefin insulation
3CIR Polymeric Crush & Impact Inner BarriHigh-strength armorless polymeric barrier rated for Class I Div 1 HL
4Oil-Resistant CPE / LSZH Outer SheathHeavy-duty flame-retardant outer jacket for deck winches & hazardous zones

CIR TC-ER-HL 600V — Standard Subsea & Offshore Execution

Built to UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification with stranded tinned copper conductors (4 cores) and oil-resistant cpe / lszh outer sheath

CIR TC-ER-HL 600V — Custom Continuous Winch / Reel Length

Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations

CIR TC-ER-HL 600V — Hydrostatic, Tensile & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
600 V (0.6/1 kV) (UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification)
Core / conductor construction
Stranded Tinned Copper Conductors (4 Cores) — 3 power cores + 1 ground conductor (18 AWG to 500 MCM)
Primary dielectric / buffering
90°C/110 °C XLPO Core Insulation — Flame-retardant cross-linked polyolefin insulation

Thermal

Continuous operating temperature
−40…+110 °C (subsea & offshore duty)
Hydrostatic & thermal stability
Verified thermal and hydrostatic stability per UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel winch reel

Mechanical

Outer protection / armouring
Oil-Resistant CPE / LSZH Outer Sheath — Heavy-duty flame-retardant outer jacket for deck winches & hazardous zones
Minimum bending radius
6 × OD
Armour, strength member & mechanical duty
CIR Polymeric Crush & Impact Inner Barrier — High-strength armorless polymeric barrier rated for Class I Div 1 HL

Resistance

Seawater, hydrostatic & hydrolysis resistance
Engineered for continuous seawater immersion, pressure cycling and hydrolysis resistance per UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification
Oil, drilling mud & abrasion resistance
Resistant to marine hydraulic oils, salt mist, winch sheave wear and seabed abrasion per UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification
Environmental & test standards
IEC 60228 / IEC 60794 / ITU-T G.972 / IEEE 1580 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
CIR TC-ER-HL 600V
Sheath colour & metre marking
Continuous metre-marked black outer finish (Oil-Resistant CP)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard CIR TC-ER-HL 600V subsea & offshore configurations

Manufactured to UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification for subsea, oceanographic, ROV, seismic and offshore applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Breaking / tensile
kN ≈
Min. bend R
mm
Enquiry
CIR TC-ER-HL 600V Construction Schedule (−40…+110 °C)
CIR TC-ER-HL 600V 3×16+1G16 mm²3 × 16 + 1G16 mm² (or 1C×50 mm²)IEC 60228 Class 2/5 Cu/SnCu22.492018.5135
CIR TC-ER-HL 600V 3×35+1G16 mm²3 × 35 + 1G16 mm² (or 1C×150 mm²)IEC 60228 Class 2/5 Cu/SnCu28.81,69032.0175
CIR TC-ER-HL 600V 3×95+1G50 mm²3 × 95 + 1G50 mm² (or 1C×300 mm²)IEC 60228 Class 2/5 Cu/SnCu41.23,68058.0250
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour breaking loads and continuous winch/seabed lengths available per UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, optical OTDR continuity & dimensional verification (UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification)DC resistance at 20 °C / optical attenuation and outer diameter within UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification)Zero dielectric breakdown and verified insulation resistance for 600 V (0.6/1 kV) ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile breaking load & water-blocking qualification (UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification)Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+110 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL 2225 TC-ER-HL / UL 1309 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX CIR TC-ER-HL 600V UL 2225 TC-ER-HL / UL 1309 600 V (0.6/1 kV) CE
Delivery form
Heavy-duty export fumigated wooden drums, steel oceanographic winch reels or submarine turntables
Standard lengths
500 m, 1,000 m, 3,000 m, 6,000 m or custom continuous subsea lengths
MOQ
100 m (standard configurations) · 500 m (custom subsea builds)
Lead time
2–6 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-26
Updated
2026-10-26

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define CIR TC-ER-HL 600V (CIR UL 2225 TC-ER-HL & UL 1309 600 V Crush- & Impact-Resistant Class I Div 1 Hazardous Marine Cable)?
CIR TC-ER-HL 600V (CIR UL 2225 TC-ER-HL & UL 1309 600 V Crush- & Impact-Resistant Class I Div 1 Hazardous Marine Cable) is manufactured in accordance with UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification for 600 V (0.6/1 kV) service over -40 to +110 °C. Its 4-layer construction comprises stranded tinned copper conductors (4 cores), 90°c/110 °c xlpo core insulation and oil-resistant cpe / lszh outer sheath.
What is the minimum bending radius and operating temperature range for CIR TC-ER-HL 600V?
The minimum bending radius for CIR TC-ER-HL 600V is 6 × OD across its continuous operating temperature range of -40 to +110 °C, ensuring mechanical, hydrostatic and dielectric reliability in subsea and offshore service.
How are the concentric layers of CIR TC-ER-HL 600V arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded Tinned Copper Conductors (4 Cores) — 3 power cores + 1 ground conductor (18 AWG to 500 MCM); (02) 90°C/110 °C XLPO Core Insulation — Flame-retardant cross-linked polyolefin insulation; (03) CIR Polymeric Crush & Impact Inner Barrier — High-strength armorless polymeric barrier rated for Class I Div 1 HL; (04) Oil-Resistant CPE / LSZH Outer Sheath — Heavy-duty flame-retardant outer jacket for deck winches & hazardous zones.
What factory test certificates are supplied with CIR TC-ER-HL 600V?
Every production drum of CIR TC-ER-HL 600V undergoes routine conductor resistance/OTDR continuity, high-voltage dielectric and dimensional testing per UL 2225 Type TC-ER-HL & UL 1309 Class I Div 1 Crush- & Impact-Resistant Marine Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for CIR TC-ER-HL 600V

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

CIR UL 2225 TC-ER-HL & UL 1309 600 V Crush- & Impact-Resistant Class I Div 1 Hazardous Marine Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp