IEEE 1580 Type P & UL 1309 600 V – 15 kV Class I/K Extra-Flexible Bronze-Armoured Offshore Power Cable (IEEE 1580 Type P (600 V – 15 kV)) engineered for 600 V – 15 kV service across -40 to +125 °C (min. bend radius 8 × OD).
Typical values for this cable type, based on IEEE Std 1580 Type P & UL 1309 Class I/K Extra-Flexible 600 V to 15 kV Offshore Power Specification — confirmed in the datasheet and quotation for your order.
Application fit
IEEE 1580 Type P & UL 1309 600 V – 15 kV Class I/K Extra-Flexible Bronze-Armoured Offshore Power Cable (IEEE 1580 Type P (600 V – 15 kV)) engineered for 600 V – 15 kV service across -40 to +125 °C (min. bend radius 8 × OD).
Halogen-free SHF1/SHF2, IEEE 1580 Type P or PE/PP submarine outer serving withstands marine salt mist, drilling mud and seabed/deck duty.
Approved for submarine seabed burial, J-tube pull-in, offshore platform cable ladders and shipboard bulkhead penetrations.
Extruded lead-alloy radial water barrier or cross-linked marine elastomer sheath prevents moisture ingress in subsea and wet-deck service.
Compacted copper or extra-flexible Class I/K tinned copper conductors terminate cleanly into offshore switchboards, transformers and thrus
Submarine and armoured offshore power cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: IEEE 1580 Type P 600V–15kV (IEEE Std 1580 Type P & UL 1309 Class I/K Extra-Flexible 600 V to 15 kV Offshore Power Specification) featuring class i/k extra-flexible tinned copper, 110°c xlpo dielectric & phase screens and ebmr / cpe / lszh offshore outer jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class I/K Extra-Flexible Tinned Copper | Ultra-flexible stranded tinned copper conductors (600 V to 15 kV) |
| 2 | 110°C XLPO Dielectric & Phase Screens | Cross-linked polyolefin insulation with semi-con & copper tape screens on MV |
| 3 | Bronze / Steel Wire Braid Armour | High-coverage bronze or galvanized steel wire braid over inner jacket |
| 4 | EBMR / CPE / LSZH Offshore Outer Jacket | Oil-based mud-resistant or halogen-free flame-retardant outer sheath |
Built to IEEE Std 1580 Type P & UL 1309 Class I/K Extra-Flexible 600 V to 15 kV Offshore Power Specification with class i/k extra-flexible tinned copper and ebmr / cpe / lszh offshore outer jacket
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to IEEE Std 1580 Type P & UL 1309 Class I/K Extra-Flexible 600 V to 15 kV Offshore Power Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| IEEE 1580 Type P 600V–15kV Construction Schedule (−40…+125 °C) | |||||||
| IEEE 1580 Type P 600V–15kV Config A | 3×25–50 mm² (or 3P+FO Composite) | Compacted / Class 5 Cu/SnCu + FO | 32.0 | 1,850 | 85.0 | 380 | |
| IEEE 1580 Type P 600V–15kV Config B | 3×95–150 mm² (or Heavy EOM) | Compacted / Class 5 Cu/SnCu + FO | 48.5 | 4,280 | 130.0 | 580 | |
| IEEE 1580 Type P 600V–15kV Config C | 3×240–400 mm² (or Trunk HV/MV) | Compacted Cu + Lead/Armour + FO | 78.0 | 9,650 | 210.0 | 950 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3×25–50 mm² (or 3P+FO Composite) | 0.50 | 600 V – 15 kV (Subsea/MV) | −40…+125 °C |
| 3×95–150 mm² (or Heavy EOM) | 0.19 | 600 V – 15 kV (Subsea/MV) | −40…+125 °C |
| 3×240–400 mm² (or Trunk HV/MV) | 0.08 | 600 V – 15 kV (Trunk/HV) | −40…+125 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (IEEE Std 1580 Type P & UL 1309 Class I/K Extra-Flexible 600 V to 15 kV Offshore Power Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within IEEE Std 1580 Type P & UL 1309 Class I/K Extra-Flexible 600 V to 15 kV Offshore Power Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEEE Std 1580 Type P & UL 1309 Class I/K Extra-Flexible 600 V to 15 kV Offshore Power Specification) | Zero dielectric breakdown and verified insulation resistance for 600 V – 15 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (IEEE Std 1580 Type P & UL 1309 Class I/K Extra-Flexible 600 V to 15 kV Offshore Power Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+125 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.