Contact
submarine & offshore power composite cableBS 6883 Type SW40.6/1 kV (-40 to +90 °C)HOFR Type SW4 LSZH Outer Sheath (-40

BS 6883 Type 6571TQ SW4 0.6/1 kV Single-Core EPR/LSZH Halogen-Free Offshore & Marine Power CableBS 6883 Type SW4 — 0.6/1 kV — -40 to +90 °C Subsea & Offshore Cable

BS 6883 Type 6571TQ SW4 0.6/1 kV Single-Core EPR/LSZH Halogen-Free Offshore & Marine Power Cable (BS 6883 Type SW4) engineered for 0.6/1 kV service across -40 to +90 °C (min. bend radius 6 × OD).

Water-resistant
Flame-retardant
Oil-resistant
Approved
Order designation
BS 6883 6571TQ SW4 3×16+1G16 mm²
Outer Ø ≈
22.4 mm
Net weight ≈
920 kg/km
Tensile rating ≈
18.5 kN
Core / stranding
IEC 60228 Class 2/5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per BS 6883 Type SW4
Operating temp.
−40…+90 °C
Continuous subsea & offshore service
Min. bend radius
6 × OD
Winch sheave, chute & seabed routing
Core / conductor
Class 2 Tinned C
Stranded tinned annealed copper single-c
Outer protection
HOFR Type SW4 LS
Heat-, oil- and flame-retardant low-smok
Standard
BS 6883 Type SW4
BS 6883:1999 Type 6571TQ GP4 EPR / Type

Typical values for this cable type, based on BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is BS 6883 6571TQ SW4 right for your machine?

BS 6883 Type 6571TQ SW4 0.6/1 kV Single-Core EPR/LSZH Halogen-Free Offshore & Marine Power Cable (BS 6883 Type SW4) engineered for 0.6/1 kV service across -40 to +90 °C (min. bend radius 6 × OD).

Offshore platform & shipboard deck trays

Suitable

Halogen-free SHF1/SHF2, IEEE 1580 Type P or PE/PP submarine outer serving withstands marine salt mist, drilling mud and seabed/deck duty.

Fixed installation

Suitable

Approved for submarine seabed burial, J-tube pull-in, offshore platform cable ladders and shipboard bulkhead penetrations.

Immersion & wet locations

Suitable

Extruded lead-alloy radial water barrier or cross-linked marine elastomer sheath prevents moisture ingress in subsea and wet-deck service.

Motor stator, traction & converter leads

Suitable

Compacted copper or extra-flexible Class I/K tinned copper conductors terminate cleanly into offshore switchboards, transformers and thrus

Energy chain / drag chain

Not suitable

Submarine and armoured offshore power cable is not designed for high-cycle automation drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableOffshore Wind Inter-Array & Export Submarine LinksSubsea Island & Platform HV/MV Power InterconnectsOffshore Oil & Gas Drilling Rigs & FPSOsCommercial Vessels, Polar Ships & Marine Propulsion

Construction

Layer by layer

Shown: BS 6883 6571TQ SW4 (BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification) featuring class 2 tinned copper conductor (2.5–400 mm²), halogen-free epr elastomeric insulation and hofr type sw4 lszh outer sheath (-40°c/+90°c) (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 2 Tinned Copper Conductor (2.5–400Stranded tinned annealed copper single-core conductor
2Halogen-Free EPR Elastomeric InsulationBS 7655 GP4 90 °C ethylene-propylene rubber dielectric
3HOFR Type SW4 LSZH Outer Sheath (-40°C/+Heat-, oil- and flame-retardant low-smoke zero-halogen jacket

BS 6883 6571TQ SW4 — Standard Subsea & Offshore Execution

Built to BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification with class 2 tinned copper conductor (2.5–400 mm²) and hofr type sw4 lszh outer sheath (-40°c/+90°c)

BS 6883 6571TQ SW4 — Custom Continuous Winch / Reel Length

Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations

BS 6883 6571TQ SW4 — Hydrostatic, Tensile & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification)
Core / conductor construction
Class 2 Tinned Copper Conductor (2.5–400 mm²) — Stranded tinned annealed copper single-core conductor
Primary dielectric / buffering
Halogen-Free EPR Elastomeric Insulation — BS 7655 GP4 90 °C ethylene-propylene rubber dielectric

Thermal

Continuous operating temperature
−40…+90 °C (subsea & offshore duty)
Hydrostatic & thermal stability
Verified thermal and hydrostatic stability per BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel winch reel

Mechanical

Outer protection / armouring
HOFR Type SW4 LSZH Outer Sheath (-40°C/+90°C) — Heat-, oil- and flame-retardant low-smoke zero-halogen jacket
Minimum bending radius
6 × OD
Armour, strength member & mechanical duty
Halogen-Free EPR Elastomeric Insulation — BS 7655 GP4 90 °C ethylene-propylene rubber dielectric

Resistance

Seawater, hydrostatic & hydrolysis resistance
Engineered for continuous seawater immersion, pressure cycling and hydrolysis resistance per BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification
Oil, drilling mud & abrasion resistance
Resistant to marine hydraulic oils, salt mist, winch sheave wear and seabed abrasion per BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification
Environmental & test standards
IEC 60228 / IEC 60794 / ITU-T G.972 / IEEE 1580 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
BS 6883 6571TQ SW4
Sheath colour & metre marking
Continuous metre-marked black outer finish (HOFR Type SW4 LS)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard BS 6883 6571TQ SW4 subsea & offshore configurations

Manufactured to BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification for subsea, oceanographic, ROV, seismic and offshore applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Breaking / tensile
kN ≈
Min. bend R
mm
Enquiry
BS 6883 6571TQ SW4 Construction Schedule (−40…+90 °C)
BS 6883 6571TQ SW4 3×16+1G16 mm²3 × 16 + 1G16 mm² (or 1C×50 mm²)IEC 60228 Class 2/5 Cu/SnCu22.492018.5135
BS 6883 6571TQ SW4 3×35+1G16 mm²3 × 35 + 1G16 mm² (or 1C×150 mm²)IEC 60228 Class 2/5 Cu/SnCu28.81,69032.0175
BS 6883 6571TQ SW4 3×95+1G50 mm²3 × 95 + 1G50 mm² (or 1C×300 mm²)IEC 60228 Class 2/5 Cu/SnCu41.23,68058.0250
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour breaking loads and continuous winch/seabed lengths available per BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, optical OTDR continuity & dimensional verification (BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification)DC resistance at 20 °C / optical attenuation and outer diameter within BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile breaking load & water-blocking qualification (BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification)Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

BS 6883 Type SW4 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX BS 6883 6571TQ SW4 BS 6883 Type SW4 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel oceanographic winch reels or submarine turntables
Standard lengths
500 m, 1,000 m, 3,000 m, 6,000 m or custom continuous subsea lengths
MOQ
100 m (standard configurations) · 500 m (custom subsea builds)
Lead time
2–6 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-26
Updated
2026-10-26

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define BS 6883 6571TQ SW4 (BS 6883 Type 6571TQ SW4 0.6/1 kV Single-Core EPR/LSZH Halogen-Free Offshore & Marine Power Cable)?
BS 6883 6571TQ SW4 (BS 6883 Type 6571TQ SW4 0.6/1 kV Single-Core EPR/LSZH Halogen-Free Offshore & Marine Power Cable) is manufactured in accordance with BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification for 0.6/1 kV service over -40 to +90 °C. Its 3-layer construction comprises class 2 tinned copper conductor (2.5–400 mm²), halogen-free epr elastomeric insulation and hofr type sw4 lszh outer sheath (-40°c/+90°c).
What is the minimum bending radius and operating temperature range for BS 6883 6571TQ SW4?
The minimum bending radius for BS 6883 6571TQ SW4 is 6 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical, hydrostatic and dielectric reliability in subsea and offshore service.
How are the concentric layers of BS 6883 6571TQ SW4 arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class 2 Tinned Copper Conductor (2.5–400 mm²) — Stranded tinned annealed copper single-core conductor; (02) Halogen-Free EPR Elastomeric Insulation — BS 7655 GP4 90 °C ethylene-propylene rubber dielectric; (03) HOFR Type SW4 LSZH Outer Sheath (-40°C/+90°C) — Heat-, oil- and flame-retardant low-smoke zero-halogen jacket.
What factory test certificates are supplied with BS 6883 6571TQ SW4?
Every production drum of BS 6883 6571TQ SW4 undergoes routine conductor resistance/OTDR continuity, high-voltage dielectric and dimensional testing per BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for BS 6883 6571TQ SW4

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

BS 6883 Type 6571TQ SW4 0.6/1 kV Single-Core EPR/LSZH Halogen-Free Offshore & Marine Power Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote