Offshore platform & shipboard deck trays
Halogen-free SHF1/SHF2, IEEE 1580 Type P or PE/PP submarine outer serving withstands marine salt mist, drilling mud and seabed/deck duty.
Product
BS 6883 Type 6571TQ SW4 0.6/1 kV Single-Core EPR/LSZH Halogen-Free Offshore & Marine Power Cable (BS 6883 Type SW4) engineered for 0.6/1 kV service across -40 to +90 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification — confirmed in the datasheet and quotation for your order.
Application fit
BS 6883 Type 6571TQ SW4 0.6/1 kV Single-Core EPR/LSZH Halogen-Free Offshore & Marine Power Cable (BS 6883 Type SW4) engineered for 0.6/1 kV service across -40 to +90 °C (min. bend radius 6 × OD).
Halogen-free SHF1/SHF2, IEEE 1580 Type P or PE/PP submarine outer serving withstands marine salt mist, drilling mud and seabed/deck duty.
Approved for submarine seabed burial, J-tube pull-in, offshore platform cable ladders and shipboard bulkhead penetrations.
Extruded lead-alloy radial water barrier or cross-linked marine elastomer sheath prevents moisture ingress in subsea and wet-deck service.
Compacted copper or extra-flexible Class I/K tinned copper conductors terminate cleanly into offshore switchboards, transformers and thrus
Submarine and armoured offshore power cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: BS 6883 6571TQ SW4 (BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification) featuring class 2 tinned copper conductor (2.5–400 mm²), halogen-free epr elastomeric insulation and hofr type sw4 lszh outer sheath (-40°c/+90°c) (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 2 Tinned Copper Conductor (2.5–400 | Stranded tinned annealed copper single-core conductor |
| 2 | Halogen-Free EPR Elastomeric Insulation | BS 7655 GP4 90 °C ethylene-propylene rubber dielectric |
| 3 | HOFR Type SW4 LSZH Outer Sheath (-40°C/+ | Heat-, oil- and flame-retardant low-smoke zero-halogen jacket |
Built to BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification with class 2 tinned copper conductor (2.5–400 mm²) and hofr type sw4 lszh outer sheath (-40°c/+90°c)
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| BS 6883 6571TQ SW4 Construction Schedule (−40…+90 °C) | |||||||
| BS 6883 6571TQ SW4 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (or 1C×50 mm²) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 18.5 | 135 | |
| BS 6883 6571TQ SW4 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (or 1C×150 mm²) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 32.0 | 175 | |
| BS 6883 6571TQ SW4 3×95+1G50 mm² | 3 × 95 + 1G50 mm² (or 1C×300 mm²) | IEC 60228 Class 2/5 Cu/SnCu | 41.2 | 3,680 | 58.0 | 250 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (or 1C×50 mm²) | 1.15 | 0.6/1 kV (98 A) | −40…+90 °C |
| 3 × 35 + 1G16 mm² (or 1C×150 mm²) | 0.52 | 0.6/1 kV (158 A) | −40…+90 °C |
| 3 × 95 + 1G50 mm² (or 1C×300 mm²) | 0.19 | 0.6/1 kV (285 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (BS 6883:1999 Type 6571TQ GP4 EPR / Type SW4 LSZH 0.6/1 kV Offshore Single-Core Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.