Symmetrical 3+3 low-voltage VFD motor supply cable rated 0.6/1 kV with Class 5 bare copper conductors, 90 °C XLPE insulation, overall bare copper wire braid EMC screen (≥ 85%), and black flame-retardant ST2 PVC sheath.
Typical values for this cable type, based on TICW/06-2009 · GB/T 12706.1 · IEC 60502-1 · IEC 60228 — confirmed in the datasheet and quotation for your order.
Application fit
Symmetrical 3+3 low-voltage VFD motor supply cable rated 0.6/1 kV with Class 5 bare copper conductors, 90 °C XLPE insulation, overall bare copper wire braid EMC screen (≥ 85%), and black flame-retardant ST2 PVC sheath.
Symmetrical 3+3 geometry and ≥ 85% bare copper braid balance phase impedance and cut PWM common-mode noise.
Class 5 bare copper and three interstitial split earths simplify motor box routing and protect bearings.
90 °C XLPE insulation and flexible Class 5 stranding fit industrial centrifugal pump and compressor skids.
Black ST2 flame-retardant PVC outer sheath installs cleanly on indoor trays, racks, and cable trenches.
ST2 PVC sheath and fixed-lay 3+3 geometry are not rated for continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PURNot engineered for motorised drum reeling or tensile winding; specify rubber reeling cables instead.
Use RG / RG-D (N)SHTOEU-JConstruction
Shown: BPYJVP 0.6/1 kV 3×35 + 3×6 mm² — three Class 5 bare copper phase cores and three symmetrical green/yellow split earth conductors inside a bare copper wire braid screen.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | Class 5 flexible bare annealed copperGB/T 3956 / IEC 60228 Class 5 |
| 2 | Phase & earth insulation | 90 °C cross-linked polyethylene (XLPE), GB/T 6995 coloursYellow, green, red + 3 × green/yellow split earths |
| 3 | Fillers & binder tape | Non-hygroscopic polypropylene (PP) fillers & polyester binder tapeSymmetrical 3+3 round cabled core |
| 4 | EMC braid screen | Overall bare annealed copper wire braid (P, ≥ 85% coverage)TICW/06-2009 high-frequency EMC containment |
| 5 | Outer sheath | Black flame-retardant PVC compound (ST2)GB/T 12706.1 / IEC 60502-1 ST2 |
Three phase cores (yellow, green, red) plus three symmetrically laid green/yellow split earth cores (2.5–240 mm²).
Technical data
Sizes
Typical dimensions, IEC 60228 Class 5 conductor resistance, copper index, and approximate weights for BPYJVP 0.6/1 kV.
| Order designation | Cores × mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Copper kg/km | Weight ≈ kg/km | Min. bend R 15×D mm | Enquiry |
|---|---|---|---|---|---|---|---|
| BPYJVP 3×2.5 + 3×0.5 | 3×2.5 + 3×0.5 | 13.5 | 7.980 | 122 | 290 | 203 | |
| BPYJVP 3×4 + 3×0.75 | 3×4 + 3×0.75 | 15.0 | 4.950 | 184 | 375 | 225 | |
| BPYJVP 3×6 + 3×1 | 3×6 + 3×1 | 16.8 | 3.300 | 258 | 490 | 252 | |
| BPYJVP 3×10 + 3×1.5 | 3×10 + 3×1.5 | 19.8 | 1.910 | 410 | 760 | 297 | |
| BPYJVP 3×16 + 3×2.5 | 3×16 + 3×2.5 | 23.0 | 1.210 | 628 | 1,100 | 345 | |
| BPYJVP 3×25 + 3×4 | 3×25 + 3×4 | 27.8 | 0.780 | 960 | 1,665 | 417 | |
| BPYJVP 3×35 + 3×6 | 3×35 + 3×6 | 31.0 | 0.554 | 1,320 | 2,200 | 465 | |
| BPYJVP 3×50 + 3×10 | 3×50 + 3×10 | 35.8 | 0.386 | 1,880 | 3,050 | 537 | |
| BPYJVP 3×70 + 3×10 | 3×70 + 3×10 | 40.5 | 0.272 | 2,480 | 4,050 | 608 | |
| BPYJVP 3×95 + 3×16 | 3×95 + 3×16 | 46.0 | 0.206 | 3,370 | 5,425 | 690 | |
| BPYJVP 3×120 + 3×25 | 3×120 + 3×25 | 51.0 | 0.161 | 4,330 | 6,700 | 765 | |
| BPYJVP 3×150 + 3×25 | 3×150 + 3×25 | 56.5 | 0.129 | 5,210 | 8,150 | 848 | |
| BPYJVP 3×185 + 3×35 | 3×185 + 3×35 | 62.5 | 0.106 | 6,470 | 10,150 | 938 | |
| BPYJVP 3×240 + 3×50 | 3×240 + 3×50 | 71.0 | 0.080 | 8,430 | 13,250 | 1,065 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC high-voltage dielectric test | 3.5 kV AC for 5 min without breakdown | Every manufactured drum length |
| Conductor DC resistance check | Per IEC 60228 / GB/T 3956 Class 5 at 20 °C | Every drum length |
| Sample tests | ||
| XLPE hot-set & braid coverage check | GB/T 12706.1 hot-set & ≥ 85% Cu braid coverage | Per production lot |
| Vertical flame propagation | Self-extinguishing per IEC 60332-1-2 / GB/T 18380.12 | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.