Offshore platform & shipboard deck trays
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Product
MIL-DTL-24643/14, /19 & /22 (LSSSGU, LSSSGA, LSTSWA & LSMSWU) 600V/1000V Watertight Silicone/XLPO-Insulated Aluminum-Braid Armoured Low-Smoke Zero-Halogen Naval Shipboard Cable (MIL-DTL-24643C, 600/1000 V, -40 to +105 °C).
Typical values for this cable type, based on US Navy MIL-DTL-24643/14 (LSSSGU/A), /19 (LSTSWA) & /22 (LSMSWU) Watertight — confirmed in the datasheet and quotation for your order.
Application fit
MIL-DTL-24643/14, /19 & /22 (LSSSGU, LSSSGA, LSTSWA & LSMSWU) 600V/1000V Watertight Silicone/XLPO-Insulated Aluminum-Braid Armoured Low-Smoke Zero-Halogen Naval Shipboard Cable (MIL-DTL-24643C, 600/1000 V, -40 to +105 °C).
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.
Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.
Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.
Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: MIL-DTL-24643/14, /19 & /22 (LSSSGU / LSTSWA / LSMSWU) (US Navy MIL-DTL-24643/14 (LSSSGU/A), /19 (LSTSWA) & /22 (LSMSWU) Watertight) featuring water-blocked tinned copper conductors, cross-linked polyolefin / silicone insulation and cross-linked lszh outer jacket (u) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Water-Blocked Tinned Copper Conductors | Stranded tinned copper filled with water-blocking compound |
| 2 | Cross-Linked Polyolefin / Silicone Insul | XLPO (19, /22) or fire-resistant silicone glass (14 LSSSGU) insulation |
| 3 | Longitudinal Watertight Interstitial Fil | 100% void-free water-blocking compound preventing compartment flooding |
| 4 | Braided Aluminum Wire Armour (A) | Lightweight corrosion-resistant aluminum wire braid mechanical armour |
| 5 | Cross-Linked LSZH Outer Jacket (U) | Low-smoke zero-halogen cross-linked polyolefin naval sheath |
Built to US Navy MIL-DTL-24643/14 (LSSSGU/A), /19 (LSTSWA) & /22 (LSMSWU) Watertight with water-blocked tinned copper conductors and cross-linked lszh outer jacket (u)
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to US Navy MIL-DTL-24643/14 (LSSSGU/A), /19 (LSTSWA) & /22 (LSMSWU) Watertight for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| MIL-DTL-24643/14, /19 & /22 (LSSSGU / LSTSWA / LSMSWU) Construction Schedule (−40…+105 °C) | |||||||
| MIL-DTL-24643 4G2.5 mm² | 4 × 2.5 mm² (or 4C × 14 AWG) | IEC 60228 Class 2/5 Cu/SnCu | 13.2 | 275 | 1.5 | 80 | |
| MIL-DTL-24643 7G2.5 mm² | 7 × 2.5 mm² (or 7C × 14 AWG) | IEC 60228 Class 2/5 Cu/SnCu | 15.8 | 415 | 2.6 | 95 | |
| MIL-DTL-24643 12G1.5 mm² | 12 × 1.5 mm² (or 12C × 16 AWG) | IEC 60228 Class 2/5 Cu/SnCu | 17.4 | 495 | 2.7 | 105 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4 × 2.5 mm² (or 4C × 14 AWG) | 7.98 | 600/1000 V (26 A) | −40…+105 °C |
| 7 × 2.5 mm² (or 7C × 14 AWG) | 7.98 | 600/1000 V (21 A) | −40…+105 °C |
| 12 × 1.5 mm² (or 12C × 16 AWG) | 13.30 | 600/1000 V (14 A) | −40…+105 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (US Navy MIL-DTL-24643/14 (LSSSGU/A), /19 (LSTSWA) & /22 (LSMSWU) Watertight) | DC resistance at 20 °C / optical attenuation and outer diameter within US Navy MIL-DTL-24643/14 (LSSSGU/A), /19 (LSTSWA) & /22 (LSMSWU) Watertight tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (US Navy MIL-DTL-24643/14 (LSSSGU/A), /19 (LSTSWA) & /22 (LSMSWU) Watertight) | Zero dielectric breakdown and verified insulation resistance for 600/1000 V rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (US Navy MIL-DTL-24643/14 (LSSSGU/A), /19 (LSTSWA) & /22 (LSMSWU) Watertight) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+105 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.