Immersion & wet locations
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Product
MIL-DTL-24643/66, /67 & /68 Types LS2OW, LS3OW & LS4OW 1,000 V Watertight with Circuit Integrity Overall Foil/Braid-Shielded Shipboard & Submarine Power Cable (MIL-DTL-24643/66~/68, 0.6/1 kV, -30 °C to +105 °C, min. bend radius 8 × OD).
Typical values for this cable type, based on MIL-DTL-24643/66A, /67A & /68A Circuit-Integrity Standard — confirmed in the datasheet and quotation for your order.
Application fit
MIL-DTL-24643/66, /67 & /68 Types LS2OW, LS3OW & LS4OW 1,000 V Watertight with Circuit Integrity Overall Foil/Braid-Shielded Shipboard & Submarine Power Cable (MIL-DTL-24643/66~/68, 0.6/1 kV, -30 °C to +105 °C, min. bend radius 8 × OD).
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.
Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.
Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.
Outboard marine and feeder construction is not designed for high-speed crane festoon trolleys.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: MIL-DTL-24643/66~/68 (LS2OW / LS3OW / LS4OW) (MIL-DTL-24643/66A, /67A & /68A Circuit-Integrity Standard) featuring watertight stranded conductors (2/3/4c), silicone + glass braid insulation and irradiation cross-linked xlpo jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Watertight Stranded Conductors (2/3/4C) | Gas/water-blocked stranded copper conductors (16 AWG Navy -3 to 400 MCM) |
| 2 | Silicone + Glass Braid Insulation | Watertight thermoset silicone rubber + glass braids for fire circuit integrity |
| 3 | Watertight Fillers & Foil Shield | Watertight interstitial fillers + Aluminum/Polyester/Aluminum composite tape |
| 4 | Overall Tinned Copper Braid Shield | Tin-coated copper wire braid providing 60 dB EMC shielding (DC to 100 MHz) |
| 5 | Irradiation Cross-Linked XLPO Jacket | Low-smoke zero-halogen cross-linked polyolefin outer jacket (1,000 V rated) |
Built to MIL-DTL-24643/66A, /67A & /68A Circuit-Integrity Standard with watertight stranded conductors (2/3/4c) and irradiation cross-linked xlpo jacket
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to MIL-DTL-24643/66A, /67A & /68A Circuit-Integrity Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| MIL-DTL-24643/66~/68 (LS2OW / LS3OW / LS4OW) Construction Schedule (−30…+105 °C) | |||||||
| MIL-DTL-24643 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| MIL-DTL-24643 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| MIL-DTL-24643 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 0.6/1 kV (45–100 Ω data) | −30…+105 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 0.6/1 kV (45–100 Ω data) | −30…+105 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 0.6/1 kV (High-Power Hybrid) | −30…+105 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (MIL-DTL-24643/66A, /67A & /68A Circuit-Integrity Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within MIL-DTL-24643/66A, /67A & /68A Circuit-Integrity Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (MIL-DTL-24643/66A, /67A & /68A Circuit-Integrity Standard) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (MIL-DTL-24643/66A, /67A & /68A Circuit-Integrity Standard) | Verified submersion integrity, tensile load and thermal stability across −30…+105 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.