VFD inverter to AC motor screened feeder
Overlapping bare copper tape (P2) provides 100% radial coverage against high-frequency PWM emissions.
Product
Symmetrical 3+3 fixed-installation VFD power cable rated 0.6/1 kV with Class 2 bare copper conductors, 90 °C XLPE insulation, 100% overlapping bare annealed copper tape screen (P2), and black flame-retardant PVC sheath.
Typical values for this cable type, based on TICW/06-2009 · GB/T 12706.1 · IEC 60502-1 · IEC 60228 Cl.2 — confirmed in the datasheet and quotation for your order.
Application fit
Symmetrical 3+3 fixed-installation VFD power cable rated 0.6/1 kV with Class 2 bare copper conductors, 90 °C XLPE insulation, 100% overlapping bare annealed copper tape screen (P2), and black flame-retardant PVC sheath.
Overlapping bare copper tape (P2) provides 100% radial coverage against high-frequency PWM emissions.
Symmetrical 3+3 split earths balance phase-to-ground capacitance and suppress motor shaft voltages.
Class 2 bare copper and 100% copper tape screen excel in stationary steel-mill and heavy plant cable trenches.
Black FR-PVC (ST2) outer sheath suits stationary cable ladders, concrete trenches, and conduit ducts.
Class 2 conductors and helical copper tape are for stationary runs, not continuous drag-chain bending.
Use (N)12YRDC11Y-J/O PURNot rated for motorised cable drums or dynamic reeling; select a rubber reeling cable instead.
Use RG / RG-D (N)SHTOEU-JConstruction
Shown: BPYJVP2 0.6/1 kV 3×50 + 3×10 mm² — Class 2 bare copper phase cores and three symmetrical green/yellow split earths inside an overlapping bare copper tape screen.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | Class 2 stranded bare annealed copperGB/T 3956 / IEC 60228 Class 2 |
| 2 | Phase & earth insulation | 90 °C cross-linked polyethylene (XLPE), GB/T 6995 coloursYellow, green, red + 3 × green/yellow split earths |
| 3 | Fillers & binder tape | Non-hygroscopic polypropylene fillers & FR binder tapeSymmetrical 3+3 round cabled core |
| 4 | EMC copper tape screen | Overlapping bare annealed copper tape (P2, 100% coverage)TICW/06-2009 continuous EMC & ground-fault path |
| 5 | Outer sheath | Black flame-retardant PVC compound (ZR-PVC / ST2)GB/T 12706.1 / IEC 60502-1 ST2 |
Three XLPE phase cores (yellow, green, red) plus three symmetrically laid green/yellow split earths (4–240 mm²).
Technical data
Sizes
| Cores × mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Copper index kg/km | Weight ≈ kg/km | Min. bend R 15×D mm |
|---|---|---|---|---|---|
| 3×4 + 3×0.75 | 14.0 | 4.610 | 160 | 320 | 210 |
| 3×6 + 3×1 | 15.3 | 3.080 | 224 | 423 | 230 |
| 3×10 + 3×1.5 | 17.3 | 1.830 | 351 | 622 | 260 |
| 3×16 + 3×2.5 | 19.6 | 1.150 | 547 | 920 | 294 |
| 3×25 + 3×4 | 23.9 | 0.727 | 843 | 1,405 | 358 |
| 3×35 + 3×6 | 26.4 | 0.524 | 1,176 | 1,899 | 396 |
| 3×50 + 3×10 | 30.1 | 0.387 | 1,703 | 2,687 | 452 |
| 3×70 + 3×16 | 35.1 | 0.268 | 2,424 | 3,789 | 526 |
| 3×95 + 3×16 | 39.0 | 0.193 | 3,115 | 4,832 | 585 |
| 3×120 + 3×25 | 42.8 | 0.153 | 4,051 | 6,195 | 642 |
| 3×150 + 3×25 | 48.5 | 0.124 | 4,882 | 7,553 | 728 |
| 3×185 + 3×35 | 53.1 | 0.099 | 6,121 | 9,391 | 796 |
| 3×240 + 3×50 | 58.8 | 0.075 | 8,044 | 12,191 | 882 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC high-voltage dielectric test | 3.5 kV AC for 5 min without breakdown | Every manufactured drum |
| Conductor DC resistance test | Per IEC 60228 / GB/T 3956 Class 2 at 20 °C | Every drum length |
| Sample tests | ||
| XLPE hot-set & Cu tape overlap | GB/T 12706.1 hot-set & 100% tape lap | Per production lot |
| Vertical flame propagation | Self-extinguishing per IEC 60332-1-2 | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.