Contact
Underwater & nuclear spent-fuel pool lighting power cableNAVSEA S9320 / 10⁶ Gy600 V (15–30 A)Nuclear CSPE / PCP

52A Series 600 V Heavy-Duty Underwater & Nuclear Lighting CableNAVSEA S9320 · 600 V · Underwater & nuclear spent-fuel pool lighting power cable

52A Series Heavy-Duty (STR/Polychloroprene) & Nuclear-Grade (EPDM/CSPE) 600 V Heavy-Duty Underwater & Nuclear Lighting Power Cable (NAVSEA S9320, 600 V, -40 °C to +90 °C, min. bend radius 6 × OD).

Water-resistant
Oil-resistant
Flame-retardant
Approved
Order designation
52A SERIES Config A (Compact)
Outer Ø ≈
10.4 mm
Net weight ≈
155 kg/km
Tensile rating ≈
4.5 kN
Core / stranding
Stranded tinned Cu (IEC 60228 / ASTM)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Tested per NAVSEA S9320
Operating temp.
−40…+90 °C
Continuous subsea & marine service
Min. bend radius
6 × OD
Dynamic sheave & fixed routing
Core / conductor
3×16/14/12 AWG
Extra-flexible rope-lay annealed bare Cu
Outer protection
CSPE / Black PCP
10⁶ Gy nuclear yellow CSPE or black CR
Standard
NAVSEA S9320
NAVSEA S9320-AM-PRO-020

Typical values for this cable type, based on NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard — confirmed in the datasheet and quotation for your order.

Application fit

Is 52A SERIES right for your machine?

52A Series Heavy-Duty (STR/Polychloroprene) & Nuclear-Grade (EPDM/CSPE) 600 V Heavy-Duty Underwater & Nuclear Lighting Power Cable (NAVSEA S9320, 600 V, -40 °C to +90 °C, min. bend radius 6 × OD).

Immersion & wet locations

Suitable

Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.

Offshore platform & shipboard deck trays

Suitable

Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.

Fixed installation

Suitable

Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.

Motor stator, traction & converter leads

Suitable

Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.

Typical machinesMarine & Offshore CableNaval Shipboard & Submarine OutboardOffshore Cathodic Protection (ICCP)Underwater Welding & Nuclear PoolsDeep-Well & Seabed Pump Feeders

Construction

Layer by layer

Shown: 52A SERIES (NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard) featuring extra-flexible bare copper (3×16/14/12 awg), 90 °c epdm / styrene rubber insulation and nuclear-grade cspe / heavy-duty pcp jacket (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Extra-Flexible Bare Copper (3×16/14/12 AWG)Soft-drawn annealed bare copper rope/bunch stranding (41×#30 or 65×#34/30)
290 °C EPDM / Styrene Rubber Insulation600 V high-dielectric radiation-tolerant rubber insulation (Black, White & Green)
3Round Mold-Ready Core Lay-UpThree cores cabled round for NAVSEA S9320-AM-PRO-020 watertight overmolding
4Nuclear-Grade CSPE / Heavy-Duty PCP JacketYellow CSPE nuclear-grade jacket (52A-013/033/023) or Black Polychloroprene (52A-006/009/012)

52A SERIES — Standard Subsea & Marine Execution

Built to NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard with extra-flexible bare copper (3×16/14/12 awg) and nuclear-grade cspe / heavy-duty pcp jacket

52A SERIES — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

52A SERIES — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
600 V (NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard)
Core / conductor construction
Extra-Flexible Bare Copper (3×16/14/12 AWG) — Soft-drawn annealed bare copper rope/bunch stranding (41×#30 or 65×#34/30)
Primary dielectric / buffering
90 °C EPDM / Styrene Rubber Insulation — 600 V high-dielectric radiation-tolerant rubber insulation (Black, White & Green)

Thermal

Continuous operating temperature
−40…+90 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Nuclear-Grade CSPE / Heavy-Duty PCP Jacket — Yellow CSPE nuclear-grade jacket (52A-013/033/023) or Black Polychloroprene (52A-006/009/012)
Minimum bending radius
6 × OD
Hydrostatic, tensile & crush duty
Round Mold-Ready Core Lay-Up — Three cores cabled round for NAVSEA S9320-AM-PRO-020 watertight overmolding

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
52A SERIES
Sheath colour & metre marking
Continuous metre-marked yellow outer finish (CSPE / Black PCP)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard 52A SERIES subsea & marine configurations

Manufactured to NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
52A SERIES Construction Schedule (−40…+90 °C)
52A SERIES Config A (Compact)4×2×24 AWG + 2×18 AWG (or 4C)Stranded tinned Cu (IEC 60228 / ASTM)10.41554.585
52A SERIES Config B (Standard)4×2×20 AWG + 4×16 AWG (or 8C)Stranded tinned Cu (IEC 60228 / ASTM)13.32659.6110
52A SERIES Config C (Heavy Hybrid)8×2×20 AWG + 4×12 AWG (or 12C)Stranded tinned Cu (IEC 60228 / ASTM)16.642018.5140
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard)DC resistance at 20 °C / optical attenuation and outer diameter within NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard)Zero dielectric breakdown and verified insulation resistance for 600 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard)Verified submersion integrity, tensile load and thermal stability across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

NAVSEA S9320 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX 52A SERIES NAVSEA S9320 600 V CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define 52A SERIES (52A Series 600 V Heavy-Duty Underwater & Nuclear Lighting Cable)?
52A SERIES (52A Series 600 V Heavy-Duty Underwater & Nuclear Lighting Cable) is manufactured in accordance with NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard for 600 V service over -40 °C to +90 °C. Its 4-layer construction comprises extra-flexible bare copper (3×16/14/12 awg), 90 °c epdm / styrene rubber insulation and nuclear-grade cspe / heavy-duty pcp jacket.
What is the minimum bending radius and operating temperature range for 52A SERIES?
The minimum bending radius for 52A SERIES is 6 × OD across its continuous operating temperature range of -40 °C to +90 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of 52A SERIES arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Extra-Flexible Bare Copper (3×16/14/12 AWG) — Soft-drawn annealed bare copper rope/bunch stranding (41×#30 or 65×#34/30); (02) 90 °C EPDM / Styrene Rubber Insulation — 600 V high-dielectric radiation-tolerant rubber insulation (Black, White & Green); (03) Round Mold-Ready Core Lay-Up — Three cores cabled round for NAVSEA S9320-AM-PRO-020 watertight overmolding; (04) Nuclear-Grade CSPE / Heavy-Duty PCP Jacket — Yellow CSPE nuclear-grade jacket (52A-013/033/023) or Black Polychloroprene (52A-006/009/012).
What factory test certificates are supplied with 52A SERIES?
Every production drum of 52A SERIES undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per NAVSEA S9320-AM-PRO-020 / CERN 10⁶ Gy Nuclear Standard, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for 52A SERIES

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

52A Series 600 V Heavy-Duty Underwater & Nuclear Lighting Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote