UL Tinned Copper Flat Grounding & Bonding Braid StrapUL-listed corrosion-resistant flat woven tinned copper earthing braid

UL Tinned Cu Braid weaves fine ASTM B33 tinned annealed copper wires into a flat uninsulated grounding and EMI-bonding strap resistant to salt mist, oxidation, and vibration across switchboards, railcars, and marine cabinets.

Oil-resistant
Flame-retardant
Approved
Order designation
UL Tinned-Cu Braid Strap 1×50 mm² (30×3.0 mm)
Outer Ø
3.0 mm
Max. R20
0.397 Ω/km
Weight
529 kg/km
Min. bend R
15.0 mm
All sizes (9)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Test voltage 2.5 kV AC
Temp. (fixed)
-60°C…+150°C
Flexing: -60 °C to +150 °C
Construction
Bare Cu-ETP
Uninsulated flat woven ASTM B33
Min. bend radius
5 × OD
High-current flexible routing
Conductor
Tinned Cu · Cl.6
Per UL 467 Grounding
Size range
1×10–1×185
9 standard configurations

Typical values for this cable type, based on UL 467 Grounding · ASTM B33 Tinned Cu · DIN 46444 (ref.) — confirmed in the datasheet and quotation for your order.

Application fit

Is UL Tinned-Cu Braid Strap right for your machine?

UL Tinned Cu Braid weaves fine ASTM B33 tinned annealed copper wires into a flat uninsulated grounding and EMI-bonding strap resistant to salt mist, oxidation, and vibration across switchboards, railcars, and marine cabinets.

Fixed installation

Suitable

Durable 600 V Cu-ETP geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.

Switchgear & control cabinet wiring

Suitable

Compact 600 V Cu-ETP profile routes cleanly inside dense switchgear enclosures, BESS racks, and high-current test benches.

Control cabinet & internal panel wiring

Suitable

Compact flame-retardant 600 V Cu-ETP geometry routes neatly through dense switchgear ducts, control cabinets, and DIN-rail terminals.

Dual-tier power & PLC tray

Suitable

Screened 600 V Cu-ETP construction suppresses electromagnetic interference on shared industrial power and PLC signal trays.

Energy chain / drag chain

Not suitable

600 V Cu-ETP construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

600 V Cu-ETP outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesPower transformers, switchgear & busduct jointsResistance welding guns & heavy fabrication shopsBESS battery racks, EV test benches & rectifiersSteel mills, foundries & high-current power bays

Construction

Layer by layer

Representative construction of UL Tinned-Cu Braid Strap: IEC 60228 Class 6 extra-flexible tinned annealed copper, Uninsulated flat woven ASTM B33 tinned copper wire braid, and Uninsulated corrosion-resistant tinned copper flat braided surface.

12
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorIEC 60228 Class 6 extra-flexible tinned annealed copperIEC 60228 Class 6
2Uninsulated outer weave / layUninsulated corrosion-resistant tinned copper flat braided surfaceUL 467 Grounding

UL Tinned-Cu Braid Strap Uninsulated

Uninsulated flexible tinned copper construction for maximal natural air-cooling convection.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL 467 Grounding · ASTM B33 Tinned Cu · DIN 46444 (ref.). Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
600 V
Test voltage
2.5 kV AC
Conductor
Tinned Cu · Cl.6
Core / dielectric
Uninsulated flat woven ASTM B33 tinned
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-60 °C to +150 °C
Temp. range (flexing)
-60 °C to +150 °C
Peak / short-circuit
+160 °C (5 s)
Min. bending radius
5 × OD

Resistance

Primary performance
Salt & Corrosion Proof Tin
Environment / duty
Low-Inductance EMI Bonding
Mechanical / special
Flat Ultra-Flex Weave
Outer finish
Uninsulated corrosion-resistant tinned

Sizes

Flat Flexible Shunt & Busbar Sizes (mm²)
Cross-section
(W × H mm)
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
5×D mm
1×10 mm² (12×1.5 mm)1.51.964911117.5
1×16 mm² (16×1.8 mm)1.81.2441461749.0
1×25 mm² (22×2.0 mm)2.00.80222826810.0
1×35 mm² (25×2.5 mm)2.50.57031837212.0
1×50 mm² (30×3.0 mm)3.00.39745552915.0
1×70 mm² (35×3.5 mm)3.50.28063773918.0
1×95 mm² (40×4.2 mm)4.20.2128641,00021.0
1×120 mm² (45×4.8 mm)4.80.1661,0921,26224.0
1×185 mm² (55×6.0 mm)6.00.1091,6841,94330.0
  • Conductor DC resistance R20 at 20 °C per IEC 60228 Class 6.
  • For flat braided shunts and foils, Outer Ø indicates nominal thickness in the bending plane.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric withstand test2.5 kV AC without breakdownEvery manufactured length
Continuity & conductor DC resistancePer IEC 60228 Class 6 at 20 °CEvery drum / assembly
Sample tests
Tensile, dimensional & pressure checkRated -60 °C to +150 °C continuousPer production lot
Environmental, thermal & mechanical qualificationSalt & Corrosion Proof Tin · Low-Inductance EMI BondingType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL 467 GroundingASTM B33 Tinned CuDIN 46444 (ref.)EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

UL Tinned-Cu Braid Strap 600 V TEBAOFLEX.COM [UL 467 Grounding] [Size] [Metre mark]
Delivery form
Custom assemblies, coils or export drums
Standard lengths
Cut-to-length · 100 m · 500 m · 1,000 m
MOQ
1 assembly / 50 m (stock) · 300 m (custom)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-23
Updated
2026-11-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes UL Tinned-Cu Braid Strap suited for demanding 600 V installations?
UL Tinned-Cu Braid Strap combines IEC 60228 Class 6 extra-flexible tinned annealed copper with Uninsulated flat woven ASTM B33 tinned copper wire braid and Uninsulated corrosion-resistant tinned copper flat braided surface. Wide flat tinned weave minimizes high-frequency inductance for EMC cabinet-door and lightning earthing.
What minimum bending radius should be respected for UL Tinned-Cu Braid Strap?
Maintain a minimum bending radius of 5 × OD across -60 °C to +150 °C flexing temperatures to ensure long mechanical and dielectric service life.
Can UL Tinned-Cu Braid Strap be delivered pre-terminated with custom lugs, water fittings, or subsea connectors?
Yes. TEBAOFLEX supplies UL Tinned-Cu Braid Strap either in bulk lengths or factory-assembled with copper lugs, water-cooled swivel fittings, or molded subsea wet-mate connectors.
What quality tests and certificates accompany every shipment of UL Tinned-Cu Braid Strap?
UL Tinned-Cu Braid Strap conforms to UL 467 Grounding, ASTM B33 Tinned Cu, DIN 46444 (ref.) (Salt & Corrosion Proof Tin) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for UL Tinned-Cu Braid Strap

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

UL Tinned-Cu Braid Strap UL Tinned Copper Flat Grounding & Bonding Braid Strap

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote